Panasonic WJ-RT416V manual Connection with a PC, Connect the recorder and a PC directly

Page 46

Connection with a PC

Required devices and cables vary depending on how to connect them. Before starting the connections, check the required devices and cables for your environment. The IP addresses of the recorders in the following connection examples are the default settings.

Connect the recorder and a PC directly

Important:

When connecting the recorder and a PC directly without using a hub or a router, use a cross LAN cable to connect them.

LAN cable

(10BASE-T/100BASE-Tx, category 5, cross)

HDD

SEQUENCE

 

 

 

SEARCH

STOP

PLAY

PAUSE

REC

1

 

1

2

3

4

 

 

 

 

ERROR

 

 

 

 

SETUP

COPY

 

 

 

2

 

 

 

 

 

 

 

 

 

ALARM

MULTI

5

6

7

8

REV

FWD

 

SKIP

3

SCREEN

 

 

 

 

 

 

 

 

TIMER

 

 

 

 

 

 

 

+

4

 

9

10/0

11

12

 

 

 

 

 

 

 

 

 

 

5

ALARM

 

 

 

ESC

 

 

 

 

OPERATE

RESET

 

 

 

 

SET

 

 

 

6

 

13

14

15

16

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Disk Recorder WJ-RT416

IP address: 192.168.0.250

Subnet mask: 255.255.255.0

PC

IP address: 192.168.0.x (except 0, 250 and 255)

Subnet mask: 255.255.255.0

Add the recorder to the existing network

Install a hub or a router between the recorder and a PC. Use a LAN cable to connect between the recorder and the hub.

HDD

SEQUENCE

 

 

 

SEARCH

STOP

PLAY

PAUSE

REC

1

 

1

2

3

4

 

 

 

 

ERROR

 

 

 

 

SETUP

COPY

 

 

 

2

 

 

 

 

 

 

 

 

 

ALARM

MULT

5

6

7

8

REV

FWD

 

SKIP

3

SCREEN

 

 

 

 

 

 

 

 

TIMER

 

 

 

 

 

 

 

+

4

 

9

10/0

11

12

 

 

 

 

 

 

 

 

 

 

5

ALARM

 

 

 

ESC

 

 

 

 

OPERATE

RESET

 

 

 

 

SET

 

 

 

6

 

13

14

15

16

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Disk Recorder WJ-RT416

IP address: 192.168.0.250

Subnet mask: 255.255.255.0

Gateway address: 192.168.0.1

LAN cable

(10BASE-T/100BASE-Tx, category 5, straight)

Hub/router

IP address: 192.168.0.1

Subnet mask: 255.255.255.0

LAN

PC

IP address: 192.168.0.x (except 0, 1, 250 and 255)

Subnet mask: 255.255.255.0

Gateway address: 192.168.0.1

PC

46

Image 46
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Class 1 Laser Product Important Notice for U.S. fileds onlyDisclaimer of warranty Limitation of liabilityImportant safety instructions Contents Precautions Indication label CleaningProduct disposal/transfer MPEG-4 Visual patent portfolio licensePreface FeaturesVarious Recording Functions About these operating instructions Trademarks and registered trademarksMajor operating controls and their functions Front View6Stop button Stop 4Escape button ESC5Set button SET 7Play/Pause button PLAY/PAUSERear View 7Power cord inlet AC Connect the provided power cord to this inletImage display When displaying images on a 16-split screenExample When displaying images from camera channel 040000PMStartup Start up the recorder as followsDisplay the setup menu by pressing the Setup button Adjustment of the clock of the recorderSystem Setup window will be displayed To shut down the recorder, do the following When playing recorded images, stop playbackShutdown of the recorder Press the Stop buttonDisplay images on a single screen Available functions when displaying live imagesMonitor live images from the cameras Display images from cameras on a multi-screenSequential display on a single screen Sequential display on a 4-split screenRecording Timer recordingAlarm recording Manual recordingPlayback Available functions when playing imagesFast forward playback/Fast reverse playback Frame by frame forward playback PausingSkip playback Frame by frame reverse playbackCamera No Search and playStart Start/End Search and play with multiple search filtersSearched FilteringSearch result window will be displayed Alarm function Action at an event occurrence alarm actionRecords alarm logs Cancel the alarm actionStarts recording automatically Alarm recording Copying Duplicate Display the Copy window by pressing the Copy buttonCopy List window will be displayed Log out Log in as a different userUser Management window will be displayed Log Operation restriction differences between the user levelsCheck HDD information Maintenance window will be displayedDisk management Disk Management window will be displayedUsed CapacityHour Meter Format all the HDDs Format the HDDFormat only the selected HDD Display the Disk Management windowDisk Management window will be displayed again Stop power supply to the HDDWhen completing the HDD replacement, press the SET button Since the replace HDD is unformatted yet, format the HDDRestore HDD management information Functions and their descriptions Operate the recorder using a PCSystem requirements for a PC Installation InstallationHDD safety mode When completing the installation, press the SET buttonHDD replacement HDD additionRack mounting Connection Basic connectionConnection with RS485 cameras RS485 cable WV-CA48/50When connecting a single unit with a controller Connection with PS·Data systemsDIP switches Connect the recorder and a PC directly Connection with a PCAdd the recorder to the existing network Operation Accessible number Add the recorder to a broadband WAN Wide Area NetworkOFF Pin No Signal Operation Remark Audio IN/ALARM OUT terminalRS485 Camera port Alarm IN/CONTROL terminal Setup menu Setup menu chartBasic operation of the setup menu Configure the system settings System Setup Default Off Summer Time DST Table Auto Adjust TimeDefault Off Summer Time DST Default Search TimeConfigure the recording settings Recording Setup Configure the common recording settings Common SetupDefault Field Advanced SetupDefault 4 Sec Resolution Time Per FileConfigure the manual recording settings Manual Rec. Setup Configure the timer recording settings Timer Rec. SetupDefault On Alarm Spot Configure the alarm action settings Event SetupAlarm Buzz Default OnConfigure the alarm recording settings Alarm Rec. Setup Alarm Output Port VMD Area Setup Set the VMD areaDefault 030 sec Alarm Duration Alarm Spot Camera NoCamera Allocation Setup Configure the display settings Display SetupDefault All Status DisplayProtocol TypeCompensation Configure the network settings Network Setup Configure the RS485 settings RS485 Setup Configure the PS·Data settings PS.Data SetupAlarm Data Default None Stop BitDefault 1 bit Retry Timing Default 1 s Camera Number SetupRestrict the operable functions User Level Setup Refer to page 31 for how to log out of the recorder Set the password PasswordLogout of the recorder Logout Check the alarm log Alarm Log Maintenance functions MaintenanceCheck the Error Log Error Log Manage the HDDs Disk Management Current Temperature Highest TemperatureCheck the system information System Information Following can be checkedFollowing information will be displayed for Type Reset the current settings to the default Factory DefaultReboot the recorder Reboot System MonitorAccess Log User number 1 20, a Auto Login UserTC YYYY-MM-DD Hhmmss Restore Default Settings Check the detailed information Advanced InformationFirmware Update Operation using the system controller OperationWJ-RT416 WV-CU650Stop playback Available only when the search window isPlay Fast forward/slow playbackTroubleshooting Symptom13, 49 58-60 Symptom Input/Output SpecificationsGeneral FunctionStandard accessories Recording time lengthPanasonic Canada Inc Panasonic System Solutions CompanyFor business users in the European Union Panasonic Sales Company