Mode selection DIP switch:

1 2

The dip switch positions are defined by the attribute of the unit connected to the system’s DATA terminal.

Machine connected to the DATA port

DIP switch 1

DIP switch 2

 

 

 

Controller

OFF

ON

 

 

 

System Device

ON

OFF

 

 

 

48

Image 48
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Class 1 Laser Product Important Notice for U.S. fileds onlyDisclaimer of warranty Limitation of liabilityImportant safety instructions Contents Precautions Cleaning Product disposal/transferIndication label MPEG-4 Visual patent portfolio licenseFeatures PrefaceVarious Recording Functions About these operating instructions Trademarks and registered trademarksMajor operating controls and their functions Front View4Escape button ESC 5Set button SET6Stop button Stop 7Play/Pause button PLAY/PAUSERear View 7Power cord inlet AC Connect the provided power cord to this inletWhen displaying images on a 16-split screen Example When displaying images from camera channelImage display 040000PMStartup Start up the recorder as followsAdjustment of the clock of the recorder Display the setup menu by pressing the Setup buttonSystem Setup window will be displayed When playing recorded images, stop playback Shutdown of the recorderTo shut down the recorder, do the following Press the Stop buttonAvailable functions when displaying live images Monitor live images from the camerasDisplay images on a single screen Display images from cameras on a multi-screenSequential display on a single screen Sequential display on a 4-split screenTimer recording Alarm recordingRecording Manual recordingAvailable functions when playing images PlaybackFast forward playback/Fast reverse playback Pausing Skip playbackFrame by frame forward playback Frame by frame reverse playbackSearch and play Camera NoStart Search and play with multiple search filters SearchedStart/End FilteringSearch result window will be displayed Alarm function Action at an event occurrence alarm actionCancel the alarm action Records alarm logsStarts recording automatically Alarm recording Copying Duplicate Display the Copy window by pressing the Copy buttonCopy List window will be displayed Log in as a different user Log outUser Management window will be displayed Log Operation restriction differences between the user levelsMaintenance window will be displayed Disk managementCheck HDD information Disk Management window will be displayedCapacity UsedHour Meter Format the HDD Format only the selected HDDFormat all the HDDs Display the Disk Management windowStop power supply to the HDD When completing the HDD replacement, press the SET buttonDisk Management window will be displayed again Since the replace HDD is unformatted yet, format the HDDRestore HDD management information Operate the recorder using a PC Functions and their descriptionsSystem requirements for a PC Installation HDD safety modeInstallation When completing the installation, press the SET buttonHDD replacement HDD additionRack mounting Connection Basic connectionConnection with RS485 cameras RS485 cable WV-CA48/50When connecting a single unit with a controller Connection with PS·Data systemsDIP switches Connection with a PC Connect the recorder and a PC directlyAdd the recorder to the existing network Operation Accessible number Add the recorder to a broadband WAN Wide Area NetworkOFF Audio IN/ALARM OUT terminal Pin No Signal Operation RemarkRS485 Camera port Alarm IN/CONTROL terminal Setup menu Setup menu chartBasic operation of the setup menu Configure the system settings System Setup Auto Adjust Time Default Off Summer Time DSTDefault Off Summer Time DST Table Default Search TimeConfigure the recording settings Recording Setup Configure the common recording settings Common SetupAdvanced Setup Default 4 Sec ResolutionDefault Field Time Per FileConfigure the manual recording settings Manual Rec. Setup Configure the timer recording settings Timer Rec. SetupConfigure the alarm action settings Event Setup Alarm BuzzDefault On Alarm Spot Default OnConfigure the alarm recording settings Alarm Rec. Setup VMD Area Setup Set the VMD area Default 030 sec Alarm DurationAlarm Output Port Alarm Spot Camera NoConfigure the display settings Display Setup Default AllCamera Allocation Setup Status DisplayType ProtocolCompensation Configure the network settings Network Setup Configure the RS485 settings RS485 Setup Configure the PS·Data settings PS.Data SetupDefault None Stop Bit Default 1 bit Retry TimingAlarm Data Default 1 s Camera Number SetupRestrict the operable functions User Level Setup Set the password Password Refer to page 31 for how to log out of the recorderLogout of the recorder Logout Maintenance functions Maintenance Check the alarm log Alarm LogCheck the Error Log Error Log Current Temperature Highest Temperature Check the system information System InformationManage the HDDs Disk Management Following can be checkedReset the current settings to the default Factory Default Reboot the recorder Reboot SystemFollowing information will be displayed for Type MonitorUser number 1 20, a Auto Login User TC YYYY-MM-DD Hhmmss Restore Default SettingsAccess Log Check the detailed information Advanced InformationFirmware Update Operation using the system controller OperationWJ-RT416 WV-CU650Available only when the search window is PlayStop playback Fast forward/slow playbackTroubleshooting Symptom13, 49 58-60 Symptom Specifications GeneralInput/Output FunctionStandard accessories Recording time lengthPanasonic System Solutions Company For business users in the European UnionPanasonic Canada Inc Panasonic Sales Company
Related manuals
Manual 59 pages 63.52 Kb