Panasonic WJ-RT416 manual Configure the alarm action settings Event Setup, Alarm Buzz, Default On

Page 58

Configure the alarm action settings [Event Setup]

Configure the settings relating to the alarm action that is to be taken at an event occurrence. Refer to page 27 for further information about the event type and the alarm action.

Event Setup

Common Setup Alarm Rec. Setup

q

w

q Configure the common settings for the alarm recording [Common Setup]

Configure the common settings relating to the alarm action that is to be taken when an event (terminal alarm, VMD alarm, com- mand alarm) occurred.

 

 

Common Setup

Alarm

Buzz

 

 

On

 

Alarm

Spot

 

On

 

Pre Alarm Recording

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

Cancel

 

 

 

 

 

 

 

 

 

Alarm Buzz

Select "On" or "Off" to determine whether or not to sound the buzzer at an event occurrence. The selected duration for "Alarm Duration" of "Alarm Rec. Setup" (page 59) will be applied as the sounding duration of the buzzer.

On: Sound the buzzer

Off: Do not sound the buzzer

Default: On

Alarm Spot

Select "On" or "Off" to determine whether or not to display images from the camera that is selected for "Alarm Spot Camera No." of "Alarm Rec. Setup (Advance)" (page 59) on a single screen at an event occurrence.

On: Display images from the selected camera.

Off: Do not display images from the selected camera.

Default: On

Note:

The screen that was displayed immediately before an event resumes after the event is finished.

Pre Alarm Recording

Select "On" or "Off" to determine whether or not to start recording from the specified seconds before an event occurrence (pre-alarm recording).

On: Start the pre-alarm recording.

Off: Do not start the pre-alarm recording.

Default: Off

Notes:

Maximum recording duration of the pre-alarm recording is approximately 5 seconds. Recording duration of the pre-alarm recording varies depending on the following settings.

I Frame Interval

Capture Resolution

Rec. Quality

Rec. Frame Rate

Audio is not recorded during pre-alarm recording.

58

Image 58
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Class 1 Laser Product Important Notice for U.S. fileds onlyDisclaimer of warranty Limitation of liabilityImportant safety instructions Contents Precautions Indication label CleaningProduct disposal/transfer MPEG-4 Visual patent portfolio licensePreface FeaturesVarious Recording Functions About these operating instructions Trademarks and registered trademarksMajor operating controls and their functions Front View6Stop button Stop 4Escape button ESC5Set button SET 7Play/Pause button PLAY/PAUSERear View 7Power cord inlet AC Connect the provided power cord to this inletImage display When displaying images on a 16-split screenExample When displaying images from camera channel 040000PMStartup Start up the recorder as followsDisplay the setup menu by pressing the Setup button Adjustment of the clock of the recorderSystem Setup window will be displayed To shut down the recorder, do the following When playing recorded images, stop playbackShutdown of the recorder Press the Stop buttonDisplay images on a single screen Available functions when displaying live imagesMonitor live images from the cameras Display images from cameras on a multi-screenSequential display on a single screen Sequential display on a 4-split screenRecording Timer recordingAlarm recording Manual recordingPlayback Available functions when playing imagesFast forward playback/Fast reverse playback Frame by frame forward playback PausingSkip playback Frame by frame reverse playbackCamera No Search and playStart Start/End Search and play with multiple search filtersSearched FilteringSearch result window will be displayed Alarm function Action at an event occurrence alarm actionRecords alarm logs Cancel the alarm actionStarts recording automatically Alarm recording Copying Duplicate Display the Copy window by pressing the Copy buttonCopy List window will be displayed Log out Log in as a different userUser Management window will be displayed Log Operation restriction differences between the user levelsCheck HDD information Maintenance window will be displayedDisk management Disk Management window will be displayedUsed CapacityHour Meter Format all the HDDs Format the HDDFormat only the selected HDD Display the Disk Management windowDisk Management window will be displayed again Stop power supply to the HDDWhen completing the HDD replacement, press the SET button Since the replace HDD is unformatted yet, format the HDDRestore HDD management information Functions and their descriptions Operate the recorder using a PCSystem requirements for a PC Installation InstallationHDD safety mode When completing the installation, press the SET buttonHDD replacement HDD additionRack mounting Connection Basic connectionConnection with RS485 cameras RS485 cable WV-CA48/50When connecting a single unit with a controller Connection with PS·Data systemsDIP switches Connect the recorder and a PC directly Connection with a PCAdd the recorder to the existing network Operation Accessible number Add the recorder to a broadband WAN Wide Area NetworkOFF Pin No Signal Operation Remark Audio IN/ALARM OUT terminalRS485 Camera port Alarm IN/CONTROL terminal Setup menu Setup menu chartBasic operation of the setup menu Configure the system settings System Setup Default Off Summer Time DST Table Auto Adjust TimeDefault Off Summer Time DST Default Search TimeConfigure the recording settings Recording Setup Configure the common recording settings Common SetupDefault Field Advanced SetupDefault 4 Sec Resolution Time Per FileConfigure the manual recording settings Manual Rec. Setup Configure the timer recording settings Timer Rec. SetupDefault On Alarm Spot Configure the alarm action settings Event SetupAlarm Buzz Default OnConfigure the alarm recording settings Alarm Rec. Setup Alarm Output Port VMD Area Setup Set the VMD areaDefault 030 sec Alarm Duration Alarm Spot Camera NoCamera Allocation Setup Configure the display settings Display SetupDefault All Status DisplayProtocol TypeCompensation Configure the network settings Network Setup Configure the RS485 settings RS485 Setup Configure the PS·Data settings PS.Data SetupAlarm Data Default None Stop BitDefault 1 bit Retry Timing Default 1 s Camera Number SetupRestrict the operable functions User Level Setup Refer to page 31 for how to log out of the recorder Set the password PasswordLogout of the recorder Logout Check the alarm log Alarm Log Maintenance functions MaintenanceCheck the Error Log Error Log Manage the HDDs Disk Management Current Temperature Highest TemperatureCheck the system information System Information Following can be checkedFollowing information will be displayed for Type Reset the current settings to the default Factory DefaultReboot the recorder Reboot System MonitorAccess Log User number 1 20, a Auto Login UserTC YYYY-MM-DD Hhmmss Restore Default Settings Check the detailed information Advanced InformationFirmware Update Operation using the system controller OperationWJ-RT416 WV-CU650Stop playback Available only when the search window isPlay Fast forward/slow playbackTroubleshooting Symptom13, 49 58-60 Symptom Input/Output SpecificationsGeneral FunctionStandard accessories Recording time lengthPanasonic Canada Inc Panasonic System Solutions CompanyFor business users in the European Union Panasonic Sales Company
Related manuals
Manual 59 pages 63.52 Kb