Alarm function

The recorder will take the alarm action according to the settings when the following events occur.

Terminal alarm: When a signal is supplied from an external device such as a door sensor to the ALARM IN/CONTROL ter- minal, this is stated as an event of a terminal alarm.

VMD (Video motion detection) alarm: When motion is detected by the VMD function, this is stated as an event of a VMD alarm.

Command alarm reception: When a command alarm is supplied from the DATA port and the RS485 port, this is stated as an event of a command alarm reception.

Notes:

VMD (Video motion detection) function

When motion (luminance change) is detected in the set VMD area, it will be regarded as a VMD alarm occurrence. It is possible to configure to record images from the camera to which a VMD alarm has occurred.

Action at an event occurrence (alarm action)

The recorder will take the following alarm action according to the settings at an alarm occurrence.

• The ALARM indicator on the front of the recorder blinks red

ALARM indicator

 

HDD

SEQUENCE

 

 

 

1

 

1

2

ERROR

 

 

 

 

2

 

 

 

 

ALARM

 

MULTI

5

6

3

 

SCREEN

 

 

TIMER

4

9 10/0

5ALARM

OPERATE

RESET

 

6

13

14

Sounds the buzzer

Refer to page 58 for how to set the buzzer to sound at an event occurrence.

Provides notification to the connected system device at an event occurrence (Alarm output)

Outputs an alarm signal from the ALARM IN/CONTROL terminal on the rear of the recorder in order to activate an alarming device (when installed).

Refer to page 60 for how to configure the alarm output port settings.

Displays images from the camera to which an event has occurred on a single screen (Alarm spot) Refer to page 58 for how to configure the alarm spot settings.

Notes:

The alarm spot action will not be taken when the setup menu or a dialogue box (message window) is displayed or in the process of copying.

When an event occurred during playback, playback will automatically stop and the alarm spot action will be taken.

Moves a camera to the preset position

The camera will move to the preset position registered in advance at an event occurrence. Refer to page 60 for how to configure the settings.

Refer to the operating instructions of the connected camera for the descriptions of how to register the preset position.

Transmits alarm information to a PC via a network

Refer to the operating instructions (PDF) of the monitoring software on the provided CD-ROM for further information.

27

Image 27
Contents WJ-RT416V For Your Safety Please Read the Following Text CARE- Fully Important Notice for U.S. fileds only Class 1 Laser ProductLimitation of liability Disclaimer of warrantyImportant safety instructions Contents Precautions MPEG-4 Visual patent portfolio license CleaningProduct disposal/transfer Indication labelFeatures PrefaceVarious Recording Functions Trademarks and registered trademarks About these operating instructionsFront View Major operating controls and their functions7Play/Pause button PLAY/PAUSE 4Escape button ESC5Set button SET 6Stop button StopRear View Connect the provided power cord to this inlet 7Power cord inlet AC040000PM When displaying images on a 16-split screenExample When displaying images from camera channel Image displayStart up the recorder as follows StartupAdjustment of the clock of the recorder Display the setup menu by pressing the Setup buttonSystem Setup window will be displayed Press the Stop button When playing recorded images, stop playbackShutdown of the recorder To shut down the recorder, do the followingDisplay images from cameras on a multi-screen Available functions when displaying live imagesMonitor live images from the cameras Display images on a single screenSequential display on a 4-split screen Sequential display on a single screenManual recording Timer recordingAlarm recording RecordingAvailable functions when playing images PlaybackFast forward playback/Fast reverse playback Frame by frame reverse playback PausingSkip playback Frame by frame forward playbackSearch and play Camera NoStart Filtering Search and play with multiple search filtersSearched Start/EndSearch result window will be displayed Action at an event occurrence alarm action Alarm functionCancel the alarm action Records alarm logsStarts recording automatically Alarm recording Display the Copy window by pressing the Copy button Copying DuplicateCopy List window will be displayed Log in as a different user Log outUser Management window will be displayed Operation restriction differences between the user levels LogDisk Management window will be displayed Maintenance window will be displayedDisk management Check HDD informationCapacity UsedHour Meter Display the Disk Management window Format the HDDFormat only the selected HDD Format all the HDDsSince the replace HDD is unformatted yet, format the HDD Stop power supply to the HDDWhen completing the HDD replacement, press the SET button Disk Management window will be displayed againRestore HDD management information Operate the recorder using a PC Functions and their descriptionsSystem requirements for a PC When completing the installation, press the SET button InstallationHDD safety mode InstallationHDD addition HDD replacementRack mounting Basic connection ConnectionRS485 cable WV-CA48/50 Connection with RS485 camerasConnection with PS·Data systems When connecting a single unit with a controllerDIP switches Connection with a PC Connect the recorder and a PC directlyAdd the recorder to the existing network Add the recorder to a broadband WAN Wide Area Network Operation Accessible numberOFF Audio IN/ALARM OUT terminal Pin No Signal Operation RemarkRS485 Camera port Alarm IN/CONTROL terminal Setup menu chart Setup menuBasic operation of the setup menu Configure the system settings System Setup Default Search Time Auto Adjust TimeDefault Off Summer Time DST Default Off Summer Time DST TableConfigure the common recording settings Common Setup Configure the recording settings Recording SetupTime Per File Advanced SetupDefault 4 Sec Resolution Default FieldConfigure the timer recording settings Timer Rec. Setup Configure the manual recording settings Manual Rec. SetupDefault On Configure the alarm action settings Event SetupAlarm Buzz Default On Alarm SpotConfigure the alarm recording settings Alarm Rec. Setup Alarm Spot Camera No VMD Area Setup Set the VMD areaDefault 030 sec Alarm Duration Alarm Output PortStatus Display Configure the display settings Display SetupDefault All Camera Allocation SetupType ProtocolCompensation Configure the network settings Network Setup Configure the PS·Data settings PS.Data Setup Configure the RS485 settings RS485 SetupDefault 1 s Camera Number Setup Default None Stop BitDefault 1 bit Retry Timing Alarm DataRestrict the operable functions User Level Setup Set the password Password Refer to page 31 for how to log out of the recorderLogout of the recorder Logout Maintenance functions Maintenance Check the alarm log Alarm LogCheck the Error Log Error Log Following can be checked Current Temperature Highest TemperatureCheck the system information System Information Manage the HDDs Disk ManagementMonitor Reset the current settings to the default Factory DefaultReboot the recorder Reboot System Following information will be displayed for TypeCheck the detailed information Advanced Information User number 1 20, a Auto Login UserTC YYYY-MM-DD Hhmmss Restore Default Settings Access LogFirmware Update OperationWJ-RT416 WV-CU650 Operation using the system controllerFast forward/slow playback Available only when the search window isPlay Stop playbackSymptom Troubleshooting13, 49 58-60 Symptom Function SpecificationsGeneral Input/OutputRecording time length Standard accessoriesPanasonic Sales Company Panasonic System Solutions CompanyFor business users in the European Union Panasonic Canada Inc