5.2 RECORD TIMER

The unit provides a weekly table, consisting of two periods of time each day for scheduled recording. This option allows you to set the time each day that the unit will start and stop recording.

MAIN MENU

TIME/ TITLE

RECORD TIMER

RECORD

ALARM

COMMUNICATION

DISK

SYSTEM

GO TO TIMER PAGE

REC ENABLE :

RECORD TIMER

REC ENABLE

: OFF

TIMER

: SET

MAIN PAGE

TIMER REC ENABLE

The rec enable option is used to enable / disable the programmed scheduled recording. ON: Enables the scheduled recording.

OFF: Disables the scheduled recording.

TIMER :

This option is used to set the time that the unit will start and stop recording each day in a weekly format. There are two time periods each day available for scheduling. The time is displayed in a 24-hour clock format. If there is a time overlap between two continual time period settings, the device will automatically combine the two time-period settings into one combined time period setting.

REC SCHEDULE

START END

START END

S :06:00-16:00

12:00-18:00

REC SCHEDULE

START END

START END

S :06:00-18:00

00:00-00:00

32

Image 33
Contents Installation Operating Manual Table of Contents Limited Warranty SpecificationsMain Menu Apendix 4. -- Network ViewingFCC Notice Safety PrecautionsManufacturer’s instruction Important Safety Instructions Graphic symbol definitions Symbol MeaningIndication definitions Meaning Disclaimer Observe the following when installingDaily or weekly Maintenance Important PrecautionsCopyrights Save Original Packing MaterialsProduct Features Product FeaturesProduct Introduction Front View Description of the FRONT/REAR ViewIndicator of Timer Recording Mode Indicator of Alarm Recording ModeIndicator of Hard Disk Status Power IndicatorRear View Terminal Block Connecting with a Single Camera or a Quad Processor InstallationConnecting with a Multiplexer Basic ConnectionQuality High Ntsc System InformationRate 6 HR Size POSUpdating System Software Video format NTSC/PAL selection Set up the REC Time Mode when a multiplexer is connected Configuring Recording SettingsBasic Operations Ntsc SystemRecording Operations Manual RecordingPAL System Start END Timer RecordingMain SET REC Timer REC Schedule Start END TIMER---------------------------- SETREC Enable Timer Main Timer REC EnableAlarm Recording Externally triggered Recording60F/S Place Playback Operations Operation StatusFast Forward/Reverse Play Back Picture-by-picture Slow Forward/ReverseSearch Operations Play Back Recorded Video from a HDD of the mobile rackFull List Search Search Full List Alarm List Time Search MM DD Year HH MM Alarm list SearchTime Search SearchBackup Operations Data BackupSystem GO to Disk Disk Setting Reformat HD 3 Usage Main Backup ALL to HDDisk Setting Reformat HD 3 Usage Alarm Select Main Backup Alarm to HDMain Backup Part to HD Total 41 M Ready to GO OK Cancel Save ENTER/SAVE buttonKey Lock Operation Archive Clips into Floppy DiskSave to J0001.JPG Save to J0002.JPG Save to J000N.JPG Right/Left buttons Main MenuTitle Setting Time SettingTIME/ Title Title StampTimer Record TimerREC Schedule Start END 0600-1600 1200-1800REC Setting 60 F/SREC Quality Alarm Setting 30SEC, 1 MIN, 5 MIN, 10 MIN, and NON-STOP NET Enable OFF NET Setting SET Main SET RS232 Comm SettingCommunication RS232Backup Full Disk REFORMAT/CLEAR Disk SettingFlicker Reduction SystemHD3 Situation StatusSpecifications Ntsc PALJpeg Setup General Command FormatCommunication Protocol Command Types Keys and signalsCommand Main Category=0x02 Handshake Second Category=0x01 Request Time Second Category=0x02Set Time Second Category=0x02 Set Setup Values Second Category=0x04Request State Second Category=0x05 Description of System StateAppendix 2. -- System Default Slave Backup Complete Battery LOWNo Entry for Backup Backup IncompleteApendix 4. -- Network Viewing Connecting KV-HD01 to your networkSystem Requirements KV-HD01ARJ-45 PIN configuration for Ethernet Install the browsing software to your PCPhysical specification for Ethernet Open Network ViewerPicture B Picture aViewing Image System status indicatorsPlay List PgUp & PgUpChanging Record Properties Changing The Record & Timer propertiesRate QualityArchive Images to the computer Change the Timer propertiesNumber of Saving Save Abort ExitOpen the Image Viewer Quit Viewing a still JPEG-imagePrint StopDigital Video Recorder