Barco R9001280 Location and Functions of Control, Front panel terminology, Local keypad

Page 15

 

 

 

 

 

Location and Functions of Control

 

 

 

 

 

 

 

 

 

 

 

4

 

LOCATION AND FUNCTIONS OF CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front panel terminology

10 11

12 13

0 I

RS232 OUT

Th is d evice complies wit h Part 15 o f t he F CC rule s. Ope ration is subject to f ollo wing tw o co ndit ions :

(1 ) Th is device may not cau se harmful int erf eren ce

(2 ) Th is device must accept an y interference re ceived including inte rference tha t may cau se u ndesired ope ration

PROJECTOR MODE :

 

 

 

 

GREEN - OPERATION

DIAGNOSTICS

 

 

 

 

 

 

 

 

CODE

IR-RECEIVER

 

COMMUNICATION PORT

RED - STANDBY

IR-ACKNOWLEDGED

 

 

 

RS 232 IN

(800-PERIPHERALS)

REMOTE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IR-RECEIVED

1

RS232 IN : to allow communication with external compu-

1ter, e.g. IBM PC or compatible, Macintosh ...

RS232 OUT : used to connect to next projector, RS232IN

2plug (communication link for PC or MAC to the next projector).

Communication port : allows communication with the

3800 peripherals.

2

3

4

5

6

7

8

9

IR-Received :IR signals are received but not recognized

7by the projector.

Diagnostics code : a) source number

8b) error code : a two digits error code is displayed when something goes wrong inside the projector.

IR receiver : receiver for control signals transmitted from

9the RCU.

4Remote : remote input for wired remote control.

Projector mode indication : indicates the status of the

5projector.

no lighting up : power switch is not pressed.

red lighting up : power switch is pressed, projector in stand by mode.

green lighting up : projector in operational mode.

6IR-Acknowledged :IR signals are recognized.

Control Panel Terminology

a. Local keypad

10

11

12

13

Power switch : '1' = on, '0' = off

Power input : autoranging from 100 to 240 Vac.

Identification plate : name, serial number, art. number.

Voltage identification plate

Gaining access

The keypad is located behind a door, screened with the name of the projector.

To open the door, push once on the indicated side of the door and turn it to the front side of the projector.

3

4

1

2

5975348 BARCOVISION 8200 210497

 

4-1

 

Image 15
Contents Vision Page Date Rev Art. No 280497 R5975348 Barco Projection SystemsNoordlaan Kuurne Belgium Barco nv/Projection SystemsTable of Contents Service Mode Mains lead AC Power cord with CEE 7 plug Safety InstructionsInstallation instructions General safety instructionsPrescriptions de securite générales Instructions pour l’installationRemarque sur la Sécurité Fédéral communication commission FCC statementOn Repacking On InstallationOn Cleaning On ServicingRé-emballage ’InstallationEntretien et Réparation NettoyageProjector dimensions UnpackingBarcovision Battery installation in the RCU Which screen type? Installation guidelinesEnvironment What about ambient light ?Inputs and computer video format input compatibility Where to install the projector?How to install a projection lens? Definitions of the Abbreviation on drawingsLocal keypad Location and Functions of ControlFront panel terminology Control Panel TerminologyRemote control TerminologyRCU Installation SET UP System Settings Fuses Power mains cord connectionSwitching on ConnectionsSwitching to stand-by Switching off Input connectionsInput module insertion into the projector Straps on module level Video/S-video input moduleRGB input selection RGB analog input moduleComponent input module Component input selectionIndication on the input slot menu Input selection RGB3S/RG3sB input moduleSet up of the baud rate for communication with a computer OFF OFF OFF On OFF OFF OFF on OFF Connecting a Rcvds 05 to the projectorConnecting a VS05 to the projector Connecting an IR Remote Receiver 800 to the projectorProjector address How to use the RCU?Hardware set up of the projector address ControllingHow to control the projector or projectors How to display a projector address?How to program an address into the RCU? Picture controls with direct accessHow to get source information? Software version How to get a summary of your projector?Source SET UP Installation of the settings for a input sourceInput selection Enter Edit fileEdit File Options Copy RenameMove DeleteOptions Source Set Up Signal operations Video offsetGain Sync Fast/Slow Gain adjustment per colorSmoothness Still video On/OffZoom/pan Screen operationsMoves the window upwards Picture Compresses the picture in the horizontal direction Configure ConversionGeometry Picture Control in Adjustment Mode 10-1 Service ModeHow to activate the password function? Start up of the Service mode0000 Convergence adjustment of the LCD panelsRed on green convergence Green focusingBlue on green convergence Modify password Reset Lamp Run TimeLamp Run Time History 10-6 Barcovision 8200 Standard source set up files Standard Source SET UP FilesStandard Source Set Up Files Battery replacement in the RCU Battery Replacement in the RCUFocusing the lens Lens Cleaning ProcedureLenses Lenses Source numbers 90 Source Numbers 90Insert Card