Source Set Up

How finding the correct values for the displayed item?

During the installation of a file with LOAD, the horizontal period, the total number of vertical lines and the interlaced mode are automati- cally measured and filled in in the menu table. These values will be available when starting up the EDIT procedure of an active file.

Select first "Horizontal" and press ENTER to display a full image.

If the value for "Horizontal total pixels" is wrong, sampling mistakes (small vertical bars in the projected image) will be seen in the image. Select "Total" and adjust the pixel quantity. Adjust for zero bars (hint : if the number of bars increase, adjust in the other way).

The active pixels : determine the width of the window on the screen. This value is normally given in the source specifications. If not, adjust until full image is displayed (no missing pixels).

Horizontal shift : to shift the image on the screen.

Horizontal period : already filled in with the correct value when active file.

Press EXIT to return to the normal Edit file menu.

Select "Vertical" by pushing the control disk up or down and press ENTER. The full image is displayed.

The "Vertical Total lines" are already filled when an active file is selected to be edited.

The "Active lines" : number of horizontal lines determining the height of the projected image. This value is normally given in the specifica- tion of the source. If not, adjust until full image height is displayed (no missing lines)

Vertical shift : shift the image up and down (push joy stick forward or backward) on the screen until the correct image position is obtained.

Interlaced [On] or [Off] : this selection is automatically filled when active file has to be edited. If the image is wrong due to mismeasurement, use the ENTER key to toggle between [On] and [Off]. (for interlaced images, 1 frame contains 2 fields).

Read AMDS

AMDS = automatic mode detection & synchronisation

During the installation of a file with LOAD, the system measured automatically the horizontal period, the total vertical lines and the interlaced mode.

When selecting Read AMDS, the system remeasures the above indicated items.

Options

Source number : The source number of a non-active source can be changed to any other source number. This makes it possible to create already a file for future source numbers.

Clamping : the clamping determines the black level of the signal. default setting : arrow up 1

Arrow up : trailing edge of the sync pulse to start the clamp pulse.

Arrow down : leading edge of the sync pulse to start the clamp pulse

1 : narrow clamp pulse

2 : wide clamp pulse

Field polarity inverted : default [No]

This function is used for interlaced images. Both rasters of the image could be shifted in a wrong way (double lines are visible in the image). This can be corrected by inverting the field polarity to [yes].

5975348 BARCOVISION 8200 210497

EDIT FILE (Horizontal)

Total :

865 pixels

Active :

675 pixels

Shift :

116 pixels

Period :

63.7 µS

862

EDIT FILE (Horizontal)

Total :

865 pixels

Active :

675 pixels

Shift :

116 pixels

Period :

63.7 µS

863

EDIT FILE (Vertical field)

Total :

312 lines

Active :

278 lines

Shift :

+15 lines

Interlaced :

[On]

864

EDIT FILE OPTIONS

 

Source number

1

 

Clamping

[ 1]

 

Field polarity inverted

[no]

 

Vertical refresh

[sync]

 

Vertical sync polarity

[

]

 

 

858

8-3

Image 33
Contents Vision Page Date Rev Art. No 280497 R5975348 Barco Projection SystemsNoordlaan Kuurne Belgium Barco nv/Projection SystemsTable of Contents Service Mode Installation instructions Safety InstructionsGeneral safety instructions Mains lead AC Power cord with CEE 7 plugRemarque sur la Sécurité Instructions pour l’installationFédéral communication commission FCC statement Prescriptions de securite généralesOn Cleaning On InstallationOn Servicing On RepackingEntretien et Réparation ’InstallationNettoyage Ré-emballageProjector dimensions UnpackingBarcovision Battery installation in the RCU Environment Installation guidelinesWhat about ambient light ? Which screen type?How to install a projection lens? Where to install the projector?Definitions of the Abbreviation on drawings Inputs and computer video format input compatibilityFront panel terminology Location and Functions of ControlControl Panel Terminology Local keypadRemote control TerminologyRCU Installation SET UP System Settings Switching on Power mains cord connectionConnections FusesSwitching to stand-by Switching off Input connectionsInput module insertion into the projector Straps on module level Video/S-video input moduleRGB input selection RGB analog input moduleComponent input module Component input selectionIndication on the input slot menu Input selection RGB3S/RG3sB input moduleSet up of the baud rate for communication with a computer Connecting a VS05 to the projector Connecting a Rcvds 05 to the projectorConnecting an IR Remote Receiver 800 to the projector OFF OFF OFF On OFF OFF OFF on OFFHardware set up of the projector address How to use the RCU?Controlling Projector addressHow to program an address into the RCU? How to display a projector address?Picture controls with direct access How to control the projector or projectorsHow to get source information? Software version How to get a summary of your projector?Source SET UP Installation of the settings for a input sourceInput selection Enter Edit fileEdit File Options Copy RenameMove DeleteOptions Source Set Up Signal operations Video offsetGain Smoothness Gain adjustment per colorStill video On/Off Sync Fast/SlowZoom/pan Screen operationsMoves the window upwards Picture Compresses the picture in the horizontal direction Configure ConversionGeometry Picture Control in Adjustment Mode How to activate the password function? Service ModeStart up of the Service mode 10-10000 Convergence adjustment of the LCD panelsRed on green convergence Green focusingBlue on green convergence Modify password Reset Lamp Run TimeLamp Run Time History 10-6 Barcovision 8200 Standard source set up files Standard Source SET UP FilesStandard Source Set Up Files Battery replacement in the RCU Battery Replacement in the RCUFocusing the lens Lens Cleaning ProcedureLenses Lenses Source numbers 90 Source Numbers 90Insert Card