Connections
RGB analog input module.
RGB analog input terminals with separate Horizontal and Vertical sync
Always use an interface when a computer and local monitor have to be connected to the projector. Interfaces to be applied :
DIAGNOSTICS
RS232 OUT
Universal analog interface.
Order number : R9826100.
RGB 120 MHz analog interface.
Order number : R9826570.
VGA interface
Order number 120V : R9828079.
Order number 230V : R9828070
MAC interface
Order number 120V : R9828059
Order number 230V : R9828050
MAGIK interface
Order number 120V : R9828129
Order number 230V : R9828120
RGBS/RGsB analog : 5 x BNC Red : 0.7 Vpp ± 3 dB
Blue : 0.7 Vpp ± 3 dB
Green : 0.7 Vpp ± 3 dB
1 Vpp ± 3 dB if sync on green Vert. sync : 1 Vpp to 4 Vpp ± 3 dB Hor. sync / Composite sync :
1 Vpp to 4 Vpp ± 3 dB
All input signals are always 75 ohm terminated, even in the "not selected" mode.
RGB input selection :
Key in the corresponding slot number on the RCU or the local keypad.
Straps on module level :
Floating or
Red : | J3 | : strap "yes" : non floating | strap "no" : floating |
Green : J4 : strap "yes" : non floating | strap "no" : floating | ||
Blue : | J5 : strap "yes" : non floating | strap "no" : floating | |
H/C : | J6 : strap "yes" : non floating | strap "no" : floating | |
V : | J7 : strap "yes" : non floating | strap "no" : floating |
Factory preset : strap "yes", non floating input
Sync selection : strap on module level.
J8 : see drawing
Factory preset : separate sync.
Sync selection on the Input Slots menu.
The horizontal sync input can be set as separate sync input or as separate sync + video input. To change this setting, press ENTER key to start up the Adjustment mode..
ANALOG INTERFACE 120 MHz |
|
| |
ON | INPUT |
|
|
| B | H | V |
OFF |
|
|
|
R | G | INP | INP |
H / C
On
RGB ANALOG INPUT
Vert. sync
Hor. sync or Composite
sync
Blue
Green
Red
J8 Sync selection
Separate sync | Sync on green |
J3 | J4 | J5 | J6 | J7 |
Floating
Floating or non floating input
| 5975348 BARCOVISION 8200 280497 | |
|