Barco R9001280 owner manual Remote control, Terminology, Rcu

Page 16

Location and Functions of Control

b. Remote control

This remote control includes a battery powered infrared (IR) transmit-

 

ter that allows the user to control the projector remotely.

 

This remote control is used for source selection, control, adaptation

 

and set up. It includes automatic storing of :

Remote Control (RCU)

- picture controls (Brightness, Sharpness...)

 

- settings

 

15

Other functions of the remote control are :

-switching between standby and operational mode.

-switching to "pause" (blanked picture, full power for immediate restarting)

-direct access to all connected sources.

-variable adjustment speed : when pushing continuously on the control disk or the picture keys, the adjustment will be executed in an accelerated fashion.

1

14

Local keypad

9

0

STANDBY

 

EXIT

7

8

 

ENTER

 

5

6

TEXT

 

PAUSE

 

 

 

3

4

SHARPN

TINT

BRIGHTN

 

 

1

2

PHASE

COLOR

CONTRAST

 

 

15

4

14

13

12

5

10

8

9

7

2

3

4

5

6

7

ADJ

 

 

EXIT

 

 

 

ENTER

STBY

PAUSE

TEXT

FREEZ

 

HELP

-

+

 

?

PHASE

9

0

-

+

SHARPNESS

7

8

-

+

 

TINT

5

6

-

+

 

 

COLOR

3

4

-

+

 

 

BRIGHTNESS

1

2

-

+

 

 

CONTRAST

32a

13

12

11

10

9

8

Terminology

Back light key : when activated, all keys will be lighted up

1and visible in the dark.

ADJ. : ADJUST key, used to display on line help while in the

2adjustment mode.

Address key (sunk key), to enter the address of the projector

3(between 0 and 9). Press the sunk address key with a pencil, followed by pressing one digit button between 0 and 9.

STBY : stand by button - to start projection when the

4power switch is switched on.

-to switch off the projector without switching off the power switch.

5PAUSE : to stop projection for a short time, press 'PAUSE'. The image disappears but full power is retained for immedi- ate restarting.

6Help : on line help information

7

Digit buttons : direct input selection.

 

8

Picture controls : use these buttons to obtain the desired

picture analog level (see also 'Controlling').

 

9

PHASE : used to remove the instability of the image.

TEXT : when adjusting one of the image, e.g. controls during

10a meeting, the displayed bar scale can be removed by

pressing 'TEXT' key first. To re-display the bar scale on the screen, press 'TEXT' key again. 'TEXT' key only active in operational mode.

FREEZ : press to freeze the projected image.

11

12

ENTER : to start up the adjustment mode or to confirm an

adjustment or selection in the adjustment mode.

 

13

EXIT : to leave the adjustment mode or to scroll upwards

when in the adjustment mode.

 

 

 

14

Control disk (on RCU) or '+' and '-' keys (cursor keys): to

make menu selections when in the adjustment mode.

 

 

The control disk can move forward, backward, to the right or

 

to the left.

 

 

 

Comparision between control disk movement and the use of

 

the cursor keys on the local keypad :

 

RCU

=

local keypad

 

control disk up

=

'+' key up

 

control disk down

=

'-' key down

 

control disk to the right

=

'+' key right

 

control disk to the left

=

'-' key left

Use the '+' and '-' keys(cursor keys) : to increase or decrease the analog level of the image controls when they are first selected.

RC operating indication : lights up when a button on the

15remote control is pressed. (This is a visual indicator to check the operation of the remote control)

4-2

 

5975348 BARCOVISION 8200 210497

 

Image 16
Contents Vision Page Barco Projection Systems Date Rev Art. No 280497 R5975348Barco nv/Projection Systems Noordlaan Kuurne BelgiumTable of Contents Service Mode Safety Instructions Installation instructionsGeneral safety instructions Mains lead AC Power cord with CEE 7 plugInstructions pour l’installation Remarque sur la SécuritéFédéral communication commission FCC statement Prescriptions de securite généralesOn Installation On CleaningOn Servicing On Repacking’Installation Entretien et RéparationNettoyage Ré-emballageUnpacking Projector dimensionsBarcovision Battery installation in the RCU Installation guidelines Environment What about ambient light ? Which screen type?Where to install the projector? How to install a projection lens?Definitions of the Abbreviation on drawings Inputs and computer video format input compatibilityLocation and Functions of Control Front panel terminologyControl Panel Terminology Local keypadTerminology Remote controlRCU Installation SET UP System Settings Power mains cord connection Switching onConnections FusesInput connections Switching to stand-by Switching offInput module insertion into the projector Video/S-video input module Straps on module levelRGB analog input module RGB input selectionComponent input selection Component input moduleIndication on the input slot menu RGB3S/RG3sB input module Input selectionSet up of the baud rate for communication with a computer Connecting a Rcvds 05 to the projector Connecting a VS05 to the projectorConnecting an IR Remote Receiver 800 to the projector OFF OFF OFF On OFF OFF OFF on OFFHow to use the RCU? Hardware set up of the projector addressControlling Projector addressHow to display a projector address? How to program an address into the RCU?Picture controls with direct access How to control the projector or projectorsHow to get source information? How to get a summary of your projector? Software versionInstallation of the settings for a input source Source SET UPInput selection Edit file EnterEdit File Options Rename CopyDelete MoveOptions Source Set Up Video offset Signal operationsGain Gain adjustment per color SmoothnessStill video On/Off Sync Fast/SlowScreen operations Zoom/panMoves the window upwards Picture Compresses the picture in the horizontal direction Conversion ConfigureGeometry Picture Control in Adjustment Mode Service Mode How to activate the password function?Start up of the Service mode 10-1Convergence adjustment of the LCD panels 0000Green focusing Red on green convergenceBlue on green convergence Reset Lamp Run Time Modify passwordLamp Run Time History 10-6 Barcovision 8200 Standard Source SET UP Files Standard source set up filesStandard Source Set Up Files Battery Replacement in the RCU Battery replacement in the RCULens Cleaning Procedure Focusing the lensLenses Lenses Source Numbers 90 Source numbers 90Insert Card