Service Mode

Two possibilities :

1)distance between red lines is smaller than distance between green lines.

Turn screw 5 and 6 clockwise until distance between lines 5 and 6 is the same for the red and green lines.

2)distance between red lines is greater than distance between green lines.

Turn screw 5 and 6 counter clockwise until distance between lines 5 and 6 is the same for the red and green lines.

Due to this movement the lines 1, 2, 3 and 4 may be out of convergence. Repeat the above mentioned steps for the respective lines.

If all lines are correctly converged, press EXIT to return to the Test pattern menu.

Blue on green convergence.

Use the control disk to highlight Blue on green and press ENTER to display the Blue on green test pattern.

Repeat the same procedure as for Red on green lines but read blue when red is indicated.

To check the result of the convergence adjustments, highlight Hatch and press ENTER. A hatch pattern will be displayed on the screen.

ENTER : displays a hatch pattern.

EXIT : returns to the service menu.

All lines must be displayed in white, if not so repeat the convergence adjustment procedure.

 

4

 

1

6

5

3

2

 

4

 

1

6

5

3

2

CONVERGENCE

Green

Blue on Green

Red on Green

Hatch

879c

CONVERGENCE

Green

Blue on Green

Red on Green

Hatch

879d

10-4

 

5975348 BARCOVISION 8200 210497

 

Image 48
Contents Vision Page Barco Projection Systems Date Rev Art. No 280497 R5975348Barco nv/Projection Systems Noordlaan Kuurne BelgiumTable of Contents Service Mode Safety Instructions Installation instructionsGeneral safety instructions Mains lead AC Power cord with CEE 7 plugInstructions pour l’installation Remarque sur la SécuritéFédéral communication commission FCC statement Prescriptions de securite généralesOn Installation On CleaningOn Servicing On Repacking’Installation Entretien et RéparationNettoyage Ré-emballageProjector dimensions UnpackingBarcovision Battery installation in the RCU Installation guidelines EnvironmentWhat about ambient light ? Which screen type?Where to install the projector? How to install a projection lens?Definitions of the Abbreviation on drawings Inputs and computer video format input compatibilityLocation and Functions of Control Front panel terminologyControl Panel Terminology Local keypadRemote control TerminologyRCU Installation SET UP System Settings Power mains cord connection Switching onConnections FusesSwitching to stand-by Switching off Input connectionsInput module insertion into the projector Video/S-video input module Straps on module levelRGB analog input module RGB input selectionComponent input module Component input selectionIndication on the input slot menu RGB3S/RG3sB input module Input selectionSet up of the baud rate for communication with a computer Connecting a Rcvds 05 to the projector Connecting a VS05 to the projectorConnecting an IR Remote Receiver 800 to the projector OFF OFF OFF On OFF OFF OFF on OFFHow to use the RCU? Hardware set up of the projector addressControlling Projector addressHow to display a projector address? How to program an address into the RCU?Picture controls with direct access How to control the projector or projectorsHow to get source information? How to get a summary of your projector? Software versionSource SET UP Installation of the settings for a input sourceInput selection Edit file EnterEdit File Options Rename CopyMove DeleteOptions Source Set Up Signal operations Video offsetGain Gain adjustment per color SmoothnessStill video On/Off Sync Fast/SlowScreen operations Zoom/panMoves the window upwards Picture Compresses the picture in the horizontal direction Configure ConversionGeometry Picture Control in Adjustment Mode Service Mode How to activate the password function? Start up of the Service mode 10-1Convergence adjustment of the LCD panels 0000Green focusing Red on green convergenceBlue on green convergence Modify password Reset Lamp Run TimeLamp Run Time History 10-6 Barcovision 8200 Standard Source SET UP Files Standard source set up filesStandard Source Set Up Files Battery Replacement in the RCU Battery replacement in the RCUFocusing the lens Lens Cleaning ProcedureLenses Lenses Source Numbers 90 Source numbers 90Insert Card