Barco R9001280 owner manual How to get a summary of your projector?, Software version

Page 30

Controlling

How to get a summary of your projector?

The Summary gives an overview of :

-type of projector

-soft version

-lamp run time

-projector run time

-address

-installation configuration

-baud rate

-projector serial number

-lamp serial number

To display the Summary on the screen, press ENTER to start up the Main menu. Push the control disk up or down to highlight System Settings and press ENTER to display the System Settings menu.

Push the control disk up or down to highlight Summary and press ENTER. The summary will be displayed on the screen.

The following information is displayed : - type of projector : BARCOVISION 8200

MAIN MENU

Picture Control

Audio Control

System Settings

File service

Service Mode

SYSTEM SETTINGS

Lamp Control: 1500W

Installation

Input slots

Summary

Color

-software version

-Address : to change the address of the projector, see Projector Address above in this chapter.

-Installation : possible installations :

*Front/Ceiling

*Front/Table

*Rear/Ceiling

*Rear/Table

SUMMARY

Type : BARCOVISION 8200

Soft version : 1.00

Address : 1

Installation : front/ table

Baudrate : 9600

Projector run time : 104 h

Lamp run Time : 104 h

Projector Serial Number : 1012123

Lamp Serial Number : 0111111

To change the installation configuration follow the instructions in chapter Installation Set Up.

-Baud rate : transfer speed for communication with a IBM PC (or compatible) or MAC. The baud rate of the projector must be the same as the baud rate of the connected computer. When there is a difference, consult Set up of the baud rate for communication with a computer in chapter Connections.

-Projector Run Time : gives the total run time since the first start up. All projectors leave the factory with a run time of approximately 24 hours.

-lamp run time : the total time the lamp has been used since it was installed in the projector.

Attention : the total lifetime of the lamp for a safe operation is 1000 hours maximum. Do not use it longer. Always replace the lamp with an original BARCO lamp kit.

-Projector Serial number : indicates the fabrication number of the projector. This number can be useful when calling for technical assistance.

-Lamp Serial number : indicates the fabrication number of the lamp. This number can be useful when calling for technical assistance.

7-4

 

5975348 BARCOVISION 8200 280497

 

Image 30
Contents Vision Page Barco Projection Systems Date Rev Art. No 280497 R5975348Barco nv/Projection Systems Noordlaan Kuurne BelgiumTable of Contents Service Mode General safety instructions Safety InstructionsInstallation instructions Mains lead AC Power cord with CEE 7 plugFédéral communication commission FCC statement Instructions pour l’installationRemarque sur la Sécurité Prescriptions de securite généralesOn Servicing On InstallationOn Cleaning On RepackingNettoyage ’InstallationEntretien et Réparation Ré-emballageProjector dimensions UnpackingBarcovision Battery installation in the RCU What about ambient light ? Installation guidelinesEnvironment Which screen type?Definitions of the Abbreviation on drawings Where to install the projector?How to install a projection lens? Inputs and computer video format input compatibilityControl Panel Terminology Location and Functions of ControlFront panel terminology Local keypadRemote control TerminologyRCU Installation SET UP System Settings Connections Power mains cord connectionSwitching on FusesSwitching to stand-by Switching off Input connectionsInput module insertion into the projector Video/S-video input module Straps on module levelRGB analog input module RGB input selectionComponent input module Component input selectionIndication on the input slot menu RGB3S/RG3sB input module Input selectionSet up of the baud rate for communication with a computer Connecting an IR Remote Receiver 800 to the projector Connecting a Rcvds 05 to the projectorConnecting a VS05 to the projector OFF OFF OFF On OFF OFF OFF on OFFControlling How to use the RCU?Hardware set up of the projector address Projector addressPicture controls with direct access How to display a projector address?How to program an address into the RCU? How to control the projector or projectorsHow to get source information? How to get a summary of your projector? Software versionSource SET UP Installation of the settings for a input sourceInput selection Edit file EnterEdit File Options Rename CopyMove DeleteOptions Source Set Up Signal operations Video offsetGain Still video On/Off Gain adjustment per colorSmoothness Sync Fast/SlowScreen operations Zoom/panMoves the window upwards Picture Compresses the picture in the horizontal direction Configure ConversionGeometry Picture Control in Adjustment Mode Start up of the Service mode Service ModeHow to activate the password function? 10-1Convergence adjustment of the LCD panels 0000Green focusing Red on green convergenceBlue on green convergence Modify password Reset Lamp Run TimeLamp Run Time History 10-6 Barcovision 8200 Standard Source SET UP Files Standard source set up filesStandard Source Set Up Files Battery Replacement in the RCU Battery replacement in the RCUFocusing the lens Lens Cleaning ProcedureLenses Lenses Source Numbers 90 Source numbers 90Insert Card