Barco R9001280 How to display a projector address?, How to program an address into the RCU?

Page 28

Controlling

switch value

11

22

34

48

516

632

764

8128

Example : address 83

DIP switch

1 2 3 4 5 6 7 8

setting

1 1 0 0 1 0 1 0

Summary : 1x1 + 1x2 + 0x4+ 0x8+ 1x16 + 0x32 + 1x64 + 0x128 = 83

b. How to control the projector or projectors.

The projector's address may be set to any value between 0 and 255. When the address is set, the projector can be controlled now :

-RCU for addresses between 0 and 9.

-computer, e.g. IBM PC (or compatible), Apple MAC, etc. for addresses between 0 and 255.

Note : A projector will respond to a RCU set to an address of '0' regardless of what address is set in the projector itself.

c. Using the RCU.

Before using the RCU, its is necessary to enter the projector address into the RCU (only when that address is between 1 and 9). The projector with the corresponding address will listen to that specific RCU.

When address 0, 'zero address' is programmed into the RCU, every projector, without exception will listen to the commands given by this RCU.

How to display a projector address?

Press the ADDRESS key (recessed key on the RCU) with a pencil. The projector's address will be displayed in a 'Text box'. This text box disappears after a few seconds. To continue using the RCU, it is necessary to enter the same address with the digit buttons (address between 0 and 9). For example : if the Address key displays projector address 003, then press "3" digit button on the RCU to set the RCU's address to match the projector's address. Do not press digit 003. This will address the remote to '0' and control all projectors in the room.

How to program an address into the RCU?

Press the ADDRESS key (recessed key on the RCU) with a pencil and enter the address with the digit buttons. That address can be any digit between 0 and 9.

When programming '0', zero address, the RCU will control any projector regardless of the projector's address. This feature allows multiple projectors with different addresses to be controlled by a single RCU.

Picture controls with direct access.

When an image control is pressed, a text box with a bar scale, icon and function name of the control, e.g. 'brightness...' appears on the screen (only if text is ON). See example screen. The length of the bar scale and the value of the numeric indication indicate the current memorized setting for this source. The bar scale changes as the + or - buttons of the control on the RCU are pressed or the + or - buttons on the local keypad.

PROJECTOR ADDRESS

001

 

BRIGHTNESS

0

63

7-2

 

5975348 BARCOVISION 8200 280497

 

Image 28
Contents Vision Page Barco Projection Systems Date Rev Art. No 280497 R5975348Barco nv/Projection Systems Noordlaan Kuurne BelgiumTable of Contents Service Mode Safety Instructions Installation instructionsGeneral safety instructions Mains lead AC Power cord with CEE 7 plugInstructions pour l’installation Remarque sur la SécuritéFédéral communication commission FCC statement Prescriptions de securite généralesOn Installation On CleaningOn Servicing On Repacking’Installation Entretien et RéparationNettoyage Ré-emballageUnpacking Projector dimensionsBarcovision Battery installation in the RCU Installation guidelines EnvironmentWhat about ambient light ? Which screen type?Where to install the projector? How to install a projection lens?Definitions of the Abbreviation on drawings Inputs and computer video format input compatibilityLocation and Functions of Control Front panel terminologyControl Panel Terminology Local keypadTerminology Remote controlRCU Installation SET UP System Settings Power mains cord connection Switching onConnections FusesInput connections Switching to stand-by Switching offInput module insertion into the projector Video/S-video input module Straps on module levelRGB analog input module RGB input selectionComponent input selection Component input moduleIndication on the input slot menu RGB3S/RG3sB input module Input selectionSet up of the baud rate for communication with a computer Connecting a Rcvds 05 to the projector Connecting a VS05 to the projectorConnecting an IR Remote Receiver 800 to the projector OFF OFF OFF On OFF OFF OFF on OFFHow to use the RCU? Hardware set up of the projector addressControlling Projector addressHow to display a projector address? How to program an address into the RCU?Picture controls with direct access How to control the projector or projectorsHow to get source information? How to get a summary of your projector? Software versionInstallation of the settings for a input source Source SET UPInput selection Edit file EnterEdit File Options Rename CopyDelete MoveOptions Source Set Up Video offset Signal operationsGain Gain adjustment per color SmoothnessStill video On/Off Sync Fast/SlowScreen operations Zoom/panMoves the window upwards Picture Compresses the picture in the horizontal direction Conversion ConfigureGeometry Picture Control in Adjustment Mode Service Mode How to activate the password function?Start up of the Service mode 10-1Convergence adjustment of the LCD panels 0000Green focusing Red on green convergenceBlue on green convergence Reset Lamp Run Time Modify passwordLamp Run Time History 10-6 Barcovision 8200 Standard Source SET UP Files Standard source set up filesStandard Source Set Up Files Battery Replacement in the RCU Battery replacement in the RCULens Cleaning Procedure Focusing the lensLenses Lenses Source Numbers 90 Source numbers 90Insert Card