3.1.4 Ceiling pendant mount

Ceiling pendant mount requires the optional adaptor EPTZ 100 CLM.

1)Assemble the connector board to the bracket adapter by 3 M4 screws. Follow the red arrow marks at board and ceiling adapter for correct position.

1

2)Mount the bracket adapter with the connector board to the EPTZ 100 CLM. For wiring, use the upper hole or side outlet of the tube.

3)Mount the EPTZ 100 CLM to the ceiling.

4)Plug the dome module in the ceiling adapter. Make sure that position of the camera module connector fits the correct position of the connector board.

5)After plug-in, turn the camera module some degrees clockwise to latch the camera module.

3

2

6

4

5

6) Use the hex key to fix the camera position with the locking screw.

14

EPTZ100_ma_en_rev03.doc

Image 14
Contents Eptz Safety Warnings WeeeTable of Contents Device Setting Camera Introduction FeaturesOptional Accessories Delivery ScopeCamera SpecificationsAlarm CommunicationPower Physical / environmentDimensions with recessed ceiling mount adapter DimensionsDimensions with ceiling mount adapter Dimension Eptz 100 with wall mount bracket Eptz 100 WLM Dimensions wall bracket Eptz 100 WLMDimension Eptz 100 with ceiling pendant bracket Eptz 100 CPM Dimension ceiling pendant bracket Eptz 100 CPMCeiling mount InstallationMechanical Recessed ceiling mount Wall mount Ceiling pendant mount Video PowerElectrical 3 RS-485 3.1 RS-485 installation with EKB 500 keyboard 3.2 RS-485 installation with EverFocus DVR Alarm Communication Settings Baud rate and Protocol2 RS-485 ID address EPTZ100maenrev03.doc Initial Start OSD Menu SetupOperation in Setup Menu 3 RS-485 bus terminationMenu Structure OSD Structure PartControl Display Main menuSystem info Camera Advanced setting camera setupMain Setup CAM Title White BALFocus BacklightMotion DET AutoEND Zoom POS InitLens Init Exposure BrightnessReset User PresetUart Mode RET PKT Enable SpecialScan GROUP1 Speed TiltLevel GROUP2Patrol Tour ScanGROUP1 Preview PatternRecord DeleteControl Privacy Mask MASK1~4Initialize Operation with EKB 500 Keyboard General key descriptionEKB 500 Operation with Everfocus Protocol EVF-2 Operation outlineAutopan Eptz 100 setup menuPreset positions Switch Alarm Out 1-8 on Switch Alarm Out 1-8 OFF Preset toursRemote switching of Eptz 100 output relay Pattern toursEKB 500 Operation with PELCO-D/P Protocol Group 1 Tour ALL Preset TourPatrol Tour Group 2 TourSwitch relay on F4 1 Enter Switch relay OFF CLR + F4 1 Enter Switch Alarm OutDevice Setting Camera Appendix a Basic Settings AT EKB 500 KeyboardCOM Port Setting RS-485 Interface Setting Ecor / Paragon Series Appendix B Basic Settings AT Everfocus DVREDR / Edvr / Edsr Series Except EDSR100, EDSR100H System I/O Control menuRecovering Communication Settings of Camera Module General MalfunctionHead Office USA Subsidiary European Subsidiary China Subsidiary Japan Subsidiary