EverFocus EPTZ 100 manual Electrical, Video, Power

Page 15

3.2ELECTRICAL

3.2.1 Video

EPTZ 100 provides a composite 1 Vp-p video output PAL/NTSC (video system depending on ordered version) with a BNC cable socket.

Cameras and video displaying or processing equipment (DVRs, switchers etc.) require cabling with 75 Ohm video cable, e.g. RG-59, RG-12, and suitable BNC plugs.

Due to inappropriate absorbability, 50 Ohm coax cable (e.g. RG58), antenna cable and further types of coax cable are not suitable.

Make sure that the video input of the connected video device is terminated with 75 Ohm.

When interconnecting transmission lines (twisted pair, fibre optics, radio) to the speed dome, ensure the accurate receiver calibration.

3.2.2 Power

EPTZ 100 is powered by 24 VAC voltage. Connector is a 5.5 mm power cable socket.

Make sure that the used power supply complies with the power requirements of the speed dome (19 W max.). 24 VAC / 1 A power source (or higher current) is recommended.

NOTE: If the power supply is not located near the dome camera, make sure that the installation cables have sufficient diameter, otherwise the voltage drop over the power line will cause malfunction of the speed dome (min. 21.4 VAC at speed dome power input with active PTZ motors is required).

NOTE: Do not connect the power until all installation steps are done!

15

EPTZ100_ma_en_rev03.doc

Image 15
Contents Eptz Weee Safety WarningsTable of Contents Device Setting Camera Delivery Scope FeaturesOptional Accessories IntroductionCommunication SpecificationsAlarm CameraPhysical / environment PowerDimensions Dimensions with ceiling mount adapterDimensions with recessed ceiling mount adapter Dimensions wall bracket Eptz 100 WLM Dimension Eptz 100 with wall mount bracket Eptz 100 WLMDimension ceiling pendant bracket Eptz 100 CPM Dimension Eptz 100 with ceiling pendant bracket Eptz 100 CPMInstallation MechanicalCeiling mount Recessed ceiling mount Wall mount Ceiling pendant mount Power ElectricalVideo 3 RS-485 3.1 RS-485 installation with EKB 500 keyboard 3.2 RS-485 installation with EverFocus DVR Alarm Baud rate and Protocol Communication Settings2 RS-485 ID address EPTZ100maenrev03.doc 3 RS-485 bus termination OSD Menu SetupOperation in Setup Menu Initial StartOSD Structure Part Menu StructureControl Main menu System infoDisplay White BAL Advanced setting camera setupMain Setup CAM Title CameraAuto BacklightMotion DET FocusExposure Brightness Zoom POS InitLens Init ENDSpecial User PresetUart Mode RET PKT Enable ResetScan GROUP2 TiltLevel GROUP1 SpeedTour Scan GROUP1Patrol Delete PatternRecord PreviewControl MASK1~4 Privacy MaskInitialize General key description Operation with EKB 500 KeyboardOperation outline EKB 500 Operation with Everfocus Protocol EVF-2Eptz 100 setup menu Preset positionsAutopan Pattern tours Preset toursRemote switching of Eptz 100 output relay Switch Alarm Out 1-8 on Switch Alarm Out 1-8 OFFEKB 500 Operation with PELCO-D/P Protocol Group 2 Tour ALL Preset TourPatrol Tour Group 1 TourSwitch relay OFF CLR + F4 1 Enter Switch Alarm Out Switch relay on F4 1 EnterAppendix a Basic Settings AT EKB 500 Keyboard COM Port Setting RS-485 Interface SettingDevice Setting Camera System I/O Control menu Appendix B Basic Settings AT Everfocus DVREDR / Edvr / Edsr Series Except EDSR100, EDSR100H Ecor / Paragon SeriesGeneral Malfunction Recovering Communication Settings of Camera ModuleChina Subsidiary Japan Subsidiary Head Office USA Subsidiary European Subsidiary