EverFocus EPTZ 100 manual Safety Warnings, Weee

Page 2

1SAFETY WARNINGS

Do not place the device near to heaters, furnaces, other heat sources or under direct solar irradiation.

Operate the device only in locations providing the tolerable operating temperature range 0°C~40°C.

For cleaning, make sure the device is plugged off and only use a damp cloth without acid detergent.

Install the device only in dry and dustproof surroundings. Protect the device against any liquid’s penetration.

Avoid the penetration of any artefacts, e.g. through ventilation slots.

Do not open the device yourself. In case of malfunction, contact your local installer or dealer. Unauthorized opening of the device will annul the warranty claim!

Use the device only for purposes described in this manual.

Operate the device only with the power source indicated in this user manual.

ATTENTION! This is a class A product which may cause radio interference in a domestic environment; in this case, the user may be urged to take adequate measures.

This equipment has been tested and found to comply to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful

interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/ TV technician for help.

This Product is RoHS compliant.

 

 

 

Your EverFocus product is designed and

Ihr EverFocus Produkt wurde entwickelt und

 

 

 

manufactured with high quality materials and

hergestellt mit qualitativ hochwertigen Materialien

 

 

 

components which can be recycled and reused.

und Komponenten, die recycelt und wieder

 

 

 

WEEE

 

 

This symbol means that electrical and electronic

verwendet werden können.

 

 

equipment, at their end-of-life, should be

Dieses Symbol bedeutet, dass elektrische und

 

 

 

disposed of separately from your household

elektronische Geräte am Ende ihrer

 

 

 

waste.

Nutzungsdauer vom Hausmüll getrennt entsorgt

 

 

 

Please, dispose of this equipment at your local

werden sollen.

 

 

 

community waste collection/recycling centre.

Bitte entsorgen Sie dieses Gerät bei Ihrer örtlichen

 

 

 

In the European Union there are separate

kommunalen Sammelstelle oder im Recycling

 

 

 

collection systems for used electrical and

Centre.

 

 

 

electronic product.

Helfen Sie uns bitte, die Umwelt zu erhalten, in

 

 

 

 

 

 

Please, help us to conserve the environment we

der wir leben!

 

 

 

live in!

 

 

 

 

 

 

The information in this manual was current upon publication. The manufacturer reserves the right to revise and improve his products. Therefore, all specifications are subject to change without prior notice. Misprints reserved.

Please read this manual carefully before installing and using this unit. Be sure to keep it handy for later reference.

2

EPTZ100_ma_en_rev03.doc

Image 2
Contents Eptz Safety Warnings WeeeTable of Contents Device Setting Camera Introduction FeaturesOptional Accessories Delivery ScopeCamera SpecificationsAlarm CommunicationPower Physical / environmentDimensions with recessed ceiling mount adapter DimensionsDimensions with ceiling mount adapter Dimension Eptz 100 with wall mount bracket Eptz 100 WLM Dimensions wall bracket Eptz 100 WLMDimension Eptz 100 with ceiling pendant bracket Eptz 100 CPM Dimension ceiling pendant bracket Eptz 100 CPMCeiling mount InstallationMechanical Recessed ceiling mount Wall mount Ceiling pendant mount Video PowerElectrical 3 RS-485 3.1 RS-485 installation with EKB 500 keyboard 3.2 RS-485 installation with EverFocus DVR Alarm Communication Settings Baud rate and Protocol2 RS-485 ID address EPTZ100maenrev03.doc Initial Start OSD Menu SetupOperation in Setup Menu 3 RS-485 bus terminationMenu Structure OSD Structure PartControl Display Main menuSystem info Camera Advanced setting camera setupMain Setup CAM Title White BALFocus BacklightMotion DET AutoEND Zoom POS InitLens Init Exposure BrightnessReset User PresetUart Mode RET PKT Enable SpecialScan GROUP1 Speed TiltLevel GROUP2Patrol Tour ScanGROUP1 Preview PatternRecord DeleteControl Privacy Mask MASK1~4Initialize Operation with EKB 500 Keyboard General key descriptionEKB 500 Operation with Everfocus Protocol EVF-2 Operation outlineAutopan Eptz 100 setup menuPreset positions Switch Alarm Out 1-8 on Switch Alarm Out 1-8 OFF Preset toursRemote switching of Eptz 100 output relay Pattern toursEKB 500 Operation with PELCO-D/P Protocol Group 1 Tour ALL Preset TourPatrol Tour Group 2 TourSwitch relay on F4 1 Enter Switch relay OFF CLR + F4 1 Enter Switch Alarm OutDevice Setting Camera Appendix a Basic Settings AT EKB 500 KeyboardCOM Port Setting RS-485 Interface Setting Ecor / Paragon Series Appendix B Basic Settings AT Everfocus DVREDR / Edvr / Edsr Series Except EDSR100, EDSR100H System I/O Control menuRecovering Communication Settings of Camera Module General MalfunctionHead Office USA Subsidiary European Subsidiary China Subsidiary Japan Subsidiary