7 APPENDIX B: BASIC SETTINGS AT EVERFOCUS DVR

The following settings are required to establish RS-485 communication between DVR and speed dome:

7.1EDR / EDVR / EDSR SERIES (EXCEPT EDSR100, EDSR100H)

1.CAMERA menu: enter the correct RS-485 ID (address) at the speed dome camera channel.

2.CONTROL menu: under "RS485" :

BAUD RATE:

set value identical to camera baud rate

PARITY:

NONE

DATA BIT:

8

STOP BIT:

1

PROTOCOL:

set protocol identical to speed dome protocol

NOTE: The RS-485 ID in CONTROL menu is not related to speed dome control. This RS-485 ID is used for controlling DVR by external keyboard only.

7.2ECOR / PARAGON SERIES

1.CAMERA menu: enter the correct RS-485 ID (address) at the speed dome camera channel.

2.SYSTEM > I/O CONTROL menu:

BAUD RATE:

set value identical to camera baud rate

PARITY:

NONE

DATA BIT:

8

STOP BIT:

1

PROTOCOL:

set protocol identical to speed dome protocol

NOTE: The RS-485 ID in menu I/O CONTROL menu is not related to speed dome control. This RS-485 ID is used for controlling DVR by external keyboard only.

46

EPTZ100_ma_en_rev03.doc

Image 46
Contents Eptz Safety Warnings WeeeTable of Contents Device Setting Camera Introduction FeaturesOptional Accessories Delivery ScopeCamera SpecificationsAlarm CommunicationPower Physical / environmentDimensions with ceiling mount adapter DimensionsDimensions with recessed ceiling mount adapter Dimension Eptz 100 with wall mount bracket Eptz 100 WLM Dimensions wall bracket Eptz 100 WLMDimension Eptz 100 with ceiling pendant bracket Eptz 100 CPM Dimension ceiling pendant bracket Eptz 100 CPMMechanical InstallationCeiling mount Recessed ceiling mount Wall mount Ceiling pendant mount Electrical PowerVideo 3 RS-485 3.1 RS-485 installation with EKB 500 keyboard 3.2 RS-485 installation with EverFocus DVR Alarm Communication Settings Baud rate and Protocol2 RS-485 ID address EPTZ100maenrev03.doc Initial Start OSD Menu SetupOperation in Setup Menu 3 RS-485 bus terminationMenu Structure OSD Structure PartControl System info Main menuDisplay Camera Advanced setting camera setupMain Setup CAM Title White BALFocus BacklightMotion DET AutoEND Zoom POS InitLens Init Exposure BrightnessReset User PresetUart Mode RET PKT Enable SpecialScan GROUP1 Speed TiltLevel GROUP2GROUP1 Tour ScanPatrol Preview PatternRecord DeleteControl Privacy Mask MASK1~4Initialize Operation with EKB 500 Keyboard General key descriptionEKB 500 Operation with Everfocus Protocol EVF-2 Operation outlinePreset positions Eptz 100 setup menuAutopan Switch Alarm Out 1-8 on Switch Alarm Out 1-8 OFF Preset toursRemote switching of Eptz 100 output relay Pattern toursEKB 500 Operation with PELCO-D/P Protocol Group 1 Tour ALL Preset TourPatrol Tour Group 2 TourSwitch relay on F4 1 Enter Switch relay OFF CLR + F4 1 Enter Switch Alarm OutCOM Port Setting RS-485 Interface Setting Appendix a Basic Settings AT EKB 500 KeyboardDevice Setting Camera Ecor / Paragon Series Appendix B Basic Settings AT Everfocus DVREDR / Edvr / Edsr Series Except EDSR100, EDSR100H System I/O Control menuRecovering Communication Settings of Camera Module General MalfunctionHead Office USA Subsidiary European Subsidiary China Subsidiary Japan Subsidiary