EverFocus EPTZ 100 manual Backlight, Motion DET, Focus, Auto, Zoom Speed, Disp Zoom MAG

Page 28

 

 

some blue or reduce some red; if lighting is fluorescent or within white

 

 

spectrum, try to either add some red or reduce some blue.

 

 

Default values are 30 (for RED) and 40 (for BLUE); it is recommended

 

 

not to set the values too far away from these two default values.

BACKLIGHT

Back light compensation improves the image quality in scenes with extreme light behind the

 

object which usually washes out the image considerably. Back light function is used to

 

reduce, if necessary, both exposure time and video gain to avoid over-exposure.

 

Use the back light compensation for sceneries with back light only; under normal light

 

conditions, the BLC may impair the image quality.

 

OFF

BLC not active

 

LOW; MIDDLE; HIGH Levels of BLC gain. Set the level as low as possible to avoid

 

 

overmodulation.

MOTION DET

EPTZ 100 does not support this feature. Please leave the setting on OFF.

FOCUS

Submenu for setup of focus modes and features:

 

ONE_PUSH The one-push function focuses the lens after each pan / tilt / zoom

 

 

operation and turns autofocus off after focusing.

 

 

This mode is recommended for most applications.

 

AUTO

The AUTO mode enforces the lens to automatically adjust its

 

 

focusing when either the object moves or the scene has changed.

 

 

NOTE: The autofocus function requires adequate illumination of the

 

 

scenery. Especially in low lux environment, it is recommended to use

 

 

the "One Push" autofocus mode, not the "AUTO" mode.

MANUAL Manual mode to finetune and obtain the optimum focusing.

In certain conditions, such as weak contrast, dark sceneries etc., the autofocus function of the camera may not get the best focus position. In such case, the focus can be adjusted manually.

ZOOM TRK Zoom tracking - with setting ON, the lens tries to keep focus also during zoom in / zoom out operation.

Dependencies zoom modes:

 

Focus

 

One-Push

 

AUTO

 

Manual

 

 

Mode

 

 

 

 

 

 

 

 

ZOOM-TRK

ZOOM-TRK

ZOOM-TRK

 

 

 

 

Action

 

ON

off

ON

off

n/a

off

 

Change in scene

no action

no action

focusing

focusing

 

no action

 

 

 

 

 

 

 

 

 

 

Zooming

 

focusing

focusing

focusing

focusing

 

focusing

 

 

 

 

at stop

 

 

 

at stop

 

 

 

 

 

 

 

 

 

 

Pan/Tilt

 

focusing at

focusing

focusing

focusing

 

no action

 

& tilting

 

stop

at stop

 

 

 

 

 

Go to Preset

focusing at

focusing

focusing

focusing

 

no action

 

 

 

stop

at stop

 

 

 

 

ZOOM SPEED

Zoom speed setting: FAST or SLOW

 

 

D-ZOOM

Value for maximum digital zoom ratio LIMIT x2 ~ x10

DISP ZOOM MAG

ON: Overlay display of zoom position on the screen

28

EPTZ100_ma_en_rev03.doc

Image 28
Contents Eptz Safety Warnings WeeeTable of Contents Device Setting Camera Features Optional AccessoriesIntroduction Delivery ScopeSpecifications AlarmCamera CommunicationPower Physical / environmentDimensions with ceiling mount adapter DimensionsDimensions with recessed ceiling mount adapter Dimension Eptz 100 with wall mount bracket Eptz 100 WLM Dimensions wall bracket Eptz 100 WLMDimension Eptz 100 with ceiling pendant bracket Eptz 100 CPM Dimension ceiling pendant bracket Eptz 100 CPMMechanical InstallationCeiling mount Recessed ceiling mount Wall mount Ceiling pendant mount Electrical PowerVideo 3 RS-485 3.1 RS-485 installation with EKB 500 keyboard 3.2 RS-485 installation with EverFocus DVR Alarm Communication Settings Baud rate and Protocol2 RS-485 ID address EPTZ100maenrev03.doc OSD Menu Setup Operation in Setup MenuInitial Start 3 RS-485 bus terminationMenu Structure OSD Structure PartControl System info Main menuDisplay Advanced setting camera setup Main Setup CAM TitleCamera White BALBacklight Motion DETFocus AutoZoom POS Init Lens InitEND Exposure BrightnessUser Preset Uart Mode RET PKT EnableReset SpecialScan Tilt LevelGROUP1 Speed GROUP2GROUP1 Tour ScanPatrol Pattern RecordPreview DeleteControl Privacy Mask MASK1~4Initialize Operation with EKB 500 Keyboard General key descriptionEKB 500 Operation with Everfocus Protocol EVF-2 Operation outlinePreset positions Eptz 100 setup menuAutopan Preset tours Remote switching of Eptz 100 output relaySwitch Alarm Out 1-8 on Switch Alarm Out 1-8 OFF Pattern toursEKB 500 Operation with PELCO-D/P Protocol ALL Preset Tour Patrol TourGroup 1 Tour Group 2 TourSwitch relay on F4 1 Enter Switch relay OFF CLR + F4 1 Enter Switch Alarm OutCOM Port Setting RS-485 Interface Setting Appendix a Basic Settings AT EKB 500 KeyboardDevice Setting Camera Appendix B Basic Settings AT Everfocus DVR EDR / Edvr / Edsr Series Except EDSR100, EDSR100HEcor / Paragon Series System I/O Control menuRecovering Communication Settings of Camera Module General MalfunctionHead Office USA Subsidiary European Subsidiary China Subsidiary Japan Subsidiary