ZOOM POS INIT

Defines a zoom position after powering up the camera,

 

 

range is x1 ~ x10

 

LENS INIT

Reset of the autofocus lens in case of malfunction

 

END

Return to CAMERA ADVANCED SETTING page

EXPOSURE

BRIGHTNESS

Image brightness setting, range 1~100

 

IRIS

Mode of the lens iris:

 

 

AUTO:

automatic iris mode

 

 

MANUAL:

manual iris operation

SHUTTER

Electronic exposure control

 

ESC: Electronic auto shutter, the shutter speed is

 

automatically adapted to light conditions

 

NOTE: This mode item is only available for setup

 

if IRIS mode is set to "MANUAL"

 

MANUAL: Manual setup of shutter speed

 

A.FLK: Flickerless mode. Useful in sceneries with light

 

sources powered with a frequency different

 

from the camera

AGC

Automatic Gain Control, gains video signal under low light

 

conditions.

 

HIGH: AGC ON, high gain

 

NORMAL: AGC ON, normal gain

 

OFF: AGC off (SSNR and SENS-UP are not available in

 

this mode)

SSNR

Signal noise reduction. This feature improves the signal-

 

noise ratio under low-light conditions.

 

OFF: no noise reduction

 

LOW, MID, HIGH: level of noise reduction

 

NOTE: this feature requires setting AGC: NORMAL or

 

HIGH

SENS-UP

The SENS-UP function increases the light sensitivity by

 

interpolation of several images.

 

AUTO: SENS-UP function active. Enter the submenu to

 

enter the number of maximum interpolated

 

pictures (2 ~ 128)

 

NOTE: Please consider that a higher value

 

creates brighter pictures, but due to the

 

longer calculation time moving objects

 

may appear distorted in the picture.

 

(effect similar to longer exposure time at

 

photo cameras)

 

OFF: no SENS-UP function

 

NOTE: this feature requires setting AGC: NORMAL or

 

HIGH

END

Return to CAMERA ADVANCED SETTING page

29

EPTZ100_ma_en_rev03.doc

Image 29
Contents Eptz Weee Safety WarningsTable of Contents Device Setting Camera Optional Accessories FeaturesIntroduction Delivery ScopeAlarm SpecificationsCamera CommunicationPhysical / environment PowerDimensions with recessed ceiling mount adapter DimensionsDimensions with ceiling mount adapter Dimensions wall bracket Eptz 100 WLM Dimension Eptz 100 with wall mount bracket Eptz 100 WLMDimension ceiling pendant bracket Eptz 100 CPM Dimension Eptz 100 with ceiling pendant bracket Eptz 100 CPMCeiling mount InstallationMechanical Recessed ceiling mount Wall mount Ceiling pendant mount Video PowerElectrical 3 RS-485 3.1 RS-485 installation with EKB 500 keyboard 3.2 RS-485 installation with EverFocus DVR Alarm Baud rate and Protocol Communication Settings2 RS-485 ID address EPTZ100maenrev03.doc Operation in Setup Menu OSD Menu SetupInitial Start 3 RS-485 bus terminationOSD Structure Part Menu StructureControl Display Main menuSystem info Main Setup CAM Title Advanced setting camera setupCamera White BALMotion DET BacklightFocus AutoLens Init Zoom POS InitEND Exposure BrightnessUart Mode RET PKT Enable User PresetReset SpecialScan Level TiltGROUP1 Speed GROUP2Patrol Tour ScanGROUP1 Record PatternPreview DeleteControl MASK1~4 Privacy MaskInitialize General key description Operation with EKB 500 KeyboardOperation outline EKB 500 Operation with Everfocus Protocol EVF-2Autopan Eptz 100 setup menuPreset positions Remote switching of Eptz 100 output relay Preset toursSwitch Alarm Out 1-8 on Switch Alarm Out 1-8 OFF Pattern toursEKB 500 Operation with PELCO-D/P Protocol Patrol Tour ALL Preset TourGroup 1 Tour Group 2 TourSwitch relay OFF CLR + F4 1 Enter Switch Alarm Out Switch relay on F4 1 EnterDevice Setting Camera Appendix a Basic Settings AT EKB 500 KeyboardCOM Port Setting RS-485 Interface Setting EDR / Edvr / Edsr Series Except EDSR100, EDSR100H Appendix B Basic Settings AT Everfocus DVREcor / Paragon Series System I/O Control menuGeneral Malfunction Recovering Communication Settings of Camera ModuleChina Subsidiary Japan Subsidiary Head Office USA Subsidiary European Subsidiary