4.1.10 Alarm
In this menu, the alarm reactions for input contacts are defined.
RELAY | OFF/ON | 
  | It is possible to switch the output relay remotely with  | 
  | 
  | 
  | this menu item for test purpose:  | 
  | 
  | 
  | ON: output relay switched  | 
  | 
  | 
  | OFF: output relay not active (off)  | 
INPUT1...3  | PRESET x | Assignment of the preset position which is linked to  | |
  | 
  | 
  | alarm input.  | 
  | 
  | 
  | Select preset position 1~32.  | 
OUTPUT | OFF/ON | 
  | ON: the camera will go to preset [assigned preset  | 
  | 
  | 
  | position in lines above] in case of alarm.  | 
  | 
  | 
  | In case of alarm, the camera moves to the  | 
  | 
  | 
  | defined preset and stays there until manual  | 
  | 
  | 
  | PTZ control or any programmed AUTO  | 
  | 
  | 
  | RESUME function is carried out  | 
  | 
  | 
  | OFF: no reaction in case of active alarm input  | 
RETURN  | 
  | 
  | Return to main menu.  | 
4.1.11 Initialize | 
  | 
  | 
  | 
POWER ON RESET  | 
  | 
  | ON: performs a PTZ initialization similar to power on  | 
  | 
  | 
  | OFF: returns to INITIALIZE menu  | 
CAMERA DEFAULT  | 
  | 
  | ON: reset of the camera module to factory settings  | 
  | 
  | 
  | OFF: returns to INITIALIZE menu  | 
FACTORY DEFAULT | 
  | 
  | ON: reset of the pan/tilt electronics module to factory  | 
  | 
  | 
  | settings  | 
  | 
  | 
  | OFF: returns to INITIALIZE menu  | 
LENS REFRESH x DAYS  | OFF,  | Frequent initialization of zoom lens for better stability  | |
  | 
  | 1...15  | and preset precision.  | 
  | 
  | 
  | OFF: no frequent initialization  | 
  | 
  | 
  | 1...15: interval in days for initialization  | 
CAMERA REFRESH x DAYS  | OFF,  | Frequent initialization of pan/tilt mechanism for better  | |
  | 
  | 1...15  | stability and preset precision.  | 
  | 
  | 
  | OFF: no frequent initialization  | 
  | 
  | 
  | 1...15: interval in days for initialization  | 
37  | EPTZ100_ma_en_rev03.doc |