JVC manual Other Settings Using the VN-C205U Setup Tool, Authorization Level Allowed Access

Page 18

Settings (Step 2 Network Settings)

2-4 Other Settings Using the "VN-C205U Setup Tool"

Perform setting of details other than the IP address using the "VN-C205U Setup Tool" that has been installed.

1.Select [Start] [Programs] [V.NETWORKS] [VN-C205U Setup Tool] to start up the "VN-C205U Setup Tool".

Page 35

Page 48

Page 49

Page 50

Page 52

Page 53

Page 45

Page 40

Page 38

Page 36

2.Refer to the relevant pages () for setting of other details.

2-4 Other Settings Using the "VN-C205U Setup Tool" (1. Password Setting)

PCs (users) connected to this camera are regulated via an access protection function which requires a password entry.

Passwords can be set or canceled using the "VN-C205U Setup Tool".

A different password can be set for each of the 3 authorization levels, namely user, operator and administrator.

Authorization Level

Allowed Access

User

Viewing of motion images only

Operator

All operations using the V.Networks Controller

Administrator

All of the above and all settings using the VN-C205U Setup Tool

 

 

Note

Do not forget the passwords as canceling or changing of passwords is not possible unless the current and correct password is entered.

1.Start up the "VN-C205U Setup Tool", followed by selecting [User], [Operator] or [Administrator] under [Password] setting.

1 Enter a password to set password protection or to change a password. Characters entered are displayed as *.

Enter the same password in both the upper and lower boxes.

Password must be alphanumeric and not longer than 8 characters.

Note

To cancel the password setting, leave the entry box blank and click OK.

2 Click .

2.The following confirmation screen will be displayed.

Click .

Notes

For a password-protected VN-C205, a password request screen will be displayed.

VN-C205 setup will not be possible unless the correct administrator password is entered.

Security level increases in the order from user to operator to administrator. Password protection will not be valid if a password is assigned only to a lower level but not to a higher one.

34

 

 

 

35

Image 18
Contents VN-C205INSTRUCTIONS VN-C205Not apply to all appliances Information for USAPreparation Settings SettingsContents Introduction OperationCharacteristics Operating PrecautionsIntroduction Latest Updates Operating Environment Name and Function of PartsVideo setting switch Preparation Procedure Connection ExamplesAdjustment of the camera’s angle of view Flowchart of installation work for camera Getting StartedInstallation PreparationPreparation Connection/Installation Mounting the Camera to the CeilingPreparations Preparations  Connection to Alarm Input/Output Terminal  Inserting the CF cardConnect the LAN cable Connect the alarm terminalConnect the input power supply cable Point the camera in the direction you wish to captureAdjusting the iris level Adjusting the focus When installing the Camera to the electrical boxAdjusting the focal length Settings related to videoInstalling the Software Pull out the cables aside and mountWhite-spot correction Click Setting PCs IP Address Windows XPSettings Network Settings Select Internet Protocol TCP/IP and click PropertiesSelect Settings and click Properties Setting PCs IP Address WindowsFor Windows 2000, set according to the following procedure Set IP address toFor other settings, next This VN-C205U Setup Tool only allows connection of VN-C205Check settings Click Start up the V.Networks Controller.All operations using the V.Networks Controller Other Settings Using the VN-C205U Setup ToolAuthorization Level Allowed Access Viewing of motion images onlyOther Settings Using the VN-C205U Setup Tool 2. Multicast Perform area setting This section describes procedures for alarm setting Alarm InputOperation when an alarm input is activated Alarm Output Alarm 1/AlarmDetect Mode Alarm FTPOutput Set Values  Alarm Output Function/Set ValueOutput Output ValueSetting the Advance screen Recording timeRecording files Start up the VN-C205U Setup Tool and select FTP Server Other Settings Using the VN-C205U Setup Tool 6. WebOther Settings Using the VN-C205U Setup Tool 7. FTP Server Displaying still images uploaded to the /user folderTransfer error PasswordError recovery Connection error Alarm FTP Upload SettingStart up the VN-C205U Setup Tool and select Time When NTP is usedStart up the VN-C205U Setup Tool and select Memory Info Normal High SpeedConnect to VN-C205 Features that Allow Setting Using the V.Networks Controller Starting Up V.Networks ControllerMotion Detection Standby Settings Setting Using the V.Networks ControllerSelect View Specify Image Size and Upside Down settings Image Size and InversionImage Quality Setting Operations Setting Using the V.Networks ControllerFrame Rate Alarm Setting When alteration is complete, click Select Setting and Time Stamp Perform settingSelect Setting and Property Perform setting Time StampRecord/Stop Play button Operations Operation Using the V.Networks ControllerPlayback Click Playback screen is displayedSnapshot Access Authorization Level Operating EnvironmentSetting Using the Web Browser Operations Operating Using a Web BrowserStarting Up the Web Browser Setting Using the Web Browser 1. Other Settings Setting Using the Web Browser 2. View Setting  Alarm Setting Using the Web Browser 3. Alarm SettingClick to apply settings and to save the set values  Alarm OutSetting Using the Web Browser 4. FTP Setting Operations Setting Using the Web BrowserViewing Still Images Viewing Live ImagesImage Link TroubleshootingSymptom Causes/Remedial Actions Displaying a still imageSpecifications OthersTemplate テンプレート 120