JVC manual Normal, High Speed, Connect to VN-C205

Page 28

Settings (Step 2 Network Settings)

2-5 Registering Connected Camera Using the "V.Networks Controller"

The connected camera can be registered with the installed "V.Networks Controller".

1.Select [Start] [Programs] [V. NETWORKS] [V.Networks Controller] to start up the "V.Networks Controller".

2.Select [File] and [New].

3.The [New] screen will be displayed.

1 Enter the [IP Address].

Note

In a DHCP environment, enter the IP address that is assigned to this camera by the DHCP server.

2 Enter the [V.Networks Name]. Do so by using a name convenient for subsequent selection, such as the installation location or number. (1 to 40 characters)

3 A folder with the name entered in 2 will be created inside the folder specified here, and recorded files will be stored here.

4 Select the mode for acquiring images.

Normal :

Client will send requests for each image to VN-C205.

Set to Normal when using a narrow bandwidth network.

High Speed:

Images will be automatically sent from VN- C205 at the specified frame rate. A maximum transmission rate of 30 fps is possible for 640 x 480 images.

When sending out images to multiple clients at the same time, however, transmission at a rate of 30 fps for 640 x 480 images will not be possible.

Notes

Images are divided into IP fragments when set to "High Speed".

Images will be sent at the frame rate set at VN-C205. When setting the frame rate to "High Speed", do so upon ensuring that this does not impose excessive burden on the network. (Page 61)

Do not set to high speed for narrow bandwidth networks.

Maximum data transmission capacity is 8 Mbps. A maximum rate of 30 fps may not be possible for 640 x 480 images depending on the image size.

The MTU (Maximum Transmission Unit) sizes during image acquisition are as follows.

Transmission Mode

MTU Size (Bytes)

Normal

1430 Bytes

High Speed

1500 Bytes

4.Connect to VN-C205.

Note

To connect to a VN-C205 for which DHCP setting is possible, either one of the following environments will be required.

Environment where no DHCP server exists.

Environment with a DHCP server that clearly defines the IP and MAC addresses assigned to VN-C205.

54

 

 

 

55

Image 28
Contents VN-C205INSTRUCTIONS VN-C205Not apply to all appliances Information for USASettings Contents IntroductionPreparation Settings OperationOperating Precautions CharacteristicsIntroduction Latest Updates Operating Environment Name and Function of PartsVideo setting switch Preparation Procedure Connection ExamplesFlowchart of installation work for camera Getting Started InstallationAdjustment of the camera’s angle of view PreparationMounting the Camera to the Ceiling Preparation Connection/InstallationPreparations Preparations  Connection to Alarm Input/Output Terminal  Inserting the CF cardConnect the alarm terminal Connect the input power supply cableConnect the LAN cable Point the camera in the direction you wish to captureAdjusting the iris level When installing the Camera to the electrical box Adjusting the focal lengthAdjusting the focus Settings related to videoPull out the cables aside and mount Installing the SoftwareWhite-spot correction Setting PCs IP Address Windows XP Settings Network SettingsClick Select Internet Protocol TCP/IP and click PropertiesSetting PCs IP Address Windows For Windows 2000, set according to the following procedureSelect Settings and click Properties Set IP address toThis VN-C205U Setup Tool only allows connection of VN-C205 Check settingsFor other settings, next Click Start up the V.Networks Controller.Other Settings Using the VN-C205U Setup Tool Authorization Level Allowed AccessAll operations using the V.Networks Controller Viewing of motion images onlyOther Settings Using the VN-C205U Setup Tool 2. Multicast Perform area setting Alarm Input This section describes procedures for alarm settingOperation when an alarm input is activated Alarm 1/Alarm Detect ModeAlarm Output Alarm FTP Alarm Output Function/Set Value OutputOutput Set Values Output ValueRecording time Setting the Advance screenRecording files Other Settings Using the VN-C205U Setup Tool 6. Web Other Settings Using the VN-C205U Setup Tool 7. FTP ServerStart up the VN-C205U Setup Tool and select FTP Server Displaying still images uploaded to the /user folderPassword Error recovery Connection errorTransfer error Alarm FTP Upload SettingWhen NTP is used Start up the VN-C205U Setup Tool and select TimeStart up the VN-C205U Setup Tool and select Memory Info High Speed NormalConnect to VN-C205 Features that Allow Setting Using the V.Networks Controller Starting Up V.Networks ControllerSettings Setting Using the V.Networks Controller Select View Specify Image Size and Upside Down settingsMotion Detection Standby Image Size and InversionOperations Setting Using the V.Networks Controller Image Quality SettingFrame Rate Alarm Setting Select Setting and Time Stamp Perform setting Select Setting and Property Perform settingWhen alteration is complete, click Time StampRecord/Stop Operations Operation Using the V.Networks Controller PlaybackPlay button Click Playback screen is displayedSnapshot Access Authorization Level Operating EnvironmentOperations Operating Using a Web Browser Setting Using the Web BrowserStarting Up the Web Browser Setting Using the Web Browser 1. Other Settings Setting Using the Web Browser 2. View Setting Setting Using the Web Browser 3. Alarm Setting Click to apply settings and to save the set values Alarm  Alarm OutSetting Using the Web Browser 4. FTP Setting Operations Setting Using the Web BrowserViewing Still Images Viewing Live ImagesTroubleshooting Symptom Causes/Remedial ActionsImage Link Displaying a still imageSpecifications OthersTemplate テンプレート 120