JVC VN-C205 Alarm 1/Alarm, Detect Mode, Alarm Output, Message Packet, Available, Alarm FTP

Page 22

Settings (Step 2 Network Settings)

2-4 Other Settings Using the "VN-C205U Setup Tool" (4. Alarm Setting) (Continued)

 Alarm Input

 

Item

 

Function/Set Value

Initial Value

1 Alarm 1/Alarm 2

This section describes setting procedures for alarm input.

 

Mode

For selecting whether to enable or disable the input signals.

Not Available

 

 

Set Values : Available, Not Available

 

 

Detect Mode

For selecting the method for detecting input signals.

Make

 

 

Make : Detect input signals at the "Make" contact point.

 

 

 

Break : Detect input signals during "Break".

 

 

 

Toggle : Detect input signals at both "Make" and "Break".

 

 

Alarm Output

For selecting whether to output from the alarm output terminal

Not Available

 

 

when there is alarm input.

 

 

 

Not Available : Do not output from the alarm output terminal.

 

 

 

Alarm Output 1 : Send output from the Alarm Output 1 terminal.

 

 

 

Alarm Output 2 : Send output from the Alarm Output 2 terminal.

 

 

 

Note

 

 

 

 

Unless the alarm output in the "Alarm Output" tab is enabled,

 

 

 

this function will not be activated even if alarm output is

 

 

 

selected in the alarm input settings. (Page 44)

 

 

 

 

 

 

Message Packet

For setting whether to send alarm packets to the PC when there

Not Available

 

 

is alarm input.

 

 

 

 

Not Available : Do not send alarm packets.

 

 

 

Available

: Send alarm packets.

 

 

Alarm FTP

For operation according to the [Alarm FTP] in the FTP Client

Not Available

 

 

feature when there is alarm input. Please refer to FTP Client

 

 

 

Settings (Page 50) for details on alarm FTP.

 

 

 

Set Values: Available, Not Available

 

 

Shutdown

Set to "Available" to quit all operations upon alarm input. Using

Not Available

 

 

this Shutdown function enables operations of this camera to

 

 

 

end safely even during recording into CF cards.

 

 

 

Not Available : Do not shut down.

 

 

 

Available

: Shut down.

 

Note

When this is set to "Available", all alarm input except alarm output and message packets will be disabled.

Item

Function/Set Value

Initial Value

2 Relay Alarm

Set here to enable the relay alarm function, which is activated

Not Available

 

when 2 alarms are received within a preset time interval.

 

 

The sequence and time interval for the alarm input can be specified.

 

 

When [Alarm Output] is selected, alarm signal output will be

 

 

sent to the alarm output terminal on the ceiling mount accord-

 

 

ing to the output port settings.

 

Notes

A second alarm input enables this relay alarm function, and alarm will not be activated for this second input.

Unless the alarm output in the "Alarm Output" tab is

enabled, this function will not be activated even if alarm output is selected in the alarm input settings. (Page 44)

Alarm Output * Please refer to the [Alarm 1/2] item for details on the set val- *Please

Message Packet

ues.

refer to

• Alarm FTP

 

the [Alarm

• Shutdown

 

1/2] item

 

 

for the

 

 

initial

 

 

values.

 

 

 

3 Retry (1 to 3)

For setting the no. of times alarm notification is to be sent to

1

 

the "V.Networks Controller". (Set Value: 1 to 3)

 

 

Note

 

 

• Alarm notification may fail, depending on the LAN

 

 

environment in use. If it fails, set the value for alarm

 

 

notification to "3". In this case, alarm by the "V.Networks

 

 

Controller" itself is set off only once.

 

 

 

 

4 List

Press here to display the IP address of the PCs to which an

 

alarm notification is sent. ("Distribution Address List" Screen)

 

 

To delete a distribution address, select the IP address to de-

 

 

lete, followed by pressing the Delete button.

 

Notes

The list allows setting of up to 10 addresses.

Message packets will not be sent out when there are 11 or more addresses.

42

 

 

 

43

Image 22
Contents VN-C205INSTRUCTIONS VN-C205Not apply to all appliances Information for USAPreparation Settings SettingsContents Introduction OperationOperating Precautions CharacteristicsIntroduction Latest Updates Operating Environment Name and Function of PartsVideo setting switch Preparation Procedure Connection ExamplesAdjustment of the camera’s angle of view Flowchart of installation work for camera Getting StartedInstallation PreparationMounting the Camera to the Ceiling Preparation Connection/InstallationPreparations Preparations  Connection to Alarm Input/Output Terminal  Inserting the CF cardConnect the LAN cable Connect the alarm terminalConnect the input power supply cable Point the camera in the direction you wish to captureAdjusting the iris level Adjusting the focus When installing the Camera to the electrical boxAdjusting the focal length Settings related to videoPull out the cables aside and mount Installing the SoftwareWhite-spot correction Click Setting PCs IP Address Windows XPSettings Network Settings Select Internet Protocol TCP/IP and click PropertiesSelect Settings and click Properties Setting PCs IP Address WindowsFor Windows 2000, set according to the following procedure Set IP address toFor other settings, next This VN-C205U Setup Tool only allows connection of VN-C205Check settings Click Start up the V.Networks Controller.All operations using the V.Networks Controller Other Settings Using the VN-C205U Setup ToolAuthorization Level Allowed Access Viewing of motion images onlyOther Settings Using the VN-C205U Setup Tool 2. Multicast Perform area setting Alarm Input This section describes procedures for alarm settingOperation when an alarm input is activated Alarm Output Alarm 1/AlarmDetect Mode Alarm FTPOutput Set Values  Alarm Output Function/Set ValueOutput Output ValueRecording time Setting the Advance screenRecording files Start up the VN-C205U Setup Tool and select FTP Server Other Settings Using the VN-C205U Setup Tool 6. WebOther Settings Using the VN-C205U Setup Tool 7. FTP Server Displaying still images uploaded to the /user folderTransfer error PasswordError recovery Connection error Alarm FTP Upload SettingWhen NTP is used Start up the VN-C205U Setup Tool and select TimeStart up the VN-C205U Setup Tool and select Memory Info High Speed NormalConnect to VN-C205 Features that Allow Setting Using the V.Networks Controller Starting Up V.Networks ControllerMotion Detection Standby Settings Setting Using the V.Networks ControllerSelect View Specify Image Size and Upside Down settings Image Size and InversionOperations Setting Using the V.Networks Controller Image Quality SettingFrame Rate Alarm Setting When alteration is complete, click Select Setting and Time Stamp Perform settingSelect Setting and Property Perform setting Time StampRecord/Stop Play button Operations Operation Using the V.Networks ControllerPlayback Click Playback screen is displayedSnapshot Access Authorization Level Operating EnvironmentOperations Operating Using a Web Browser Setting Using the Web BrowserStarting Up the Web Browser Setting Using the Web Browser 1. Other Settings Setting Using the Web Browser 2. View Setting  Alarm Setting Using the Web Browser 3. Alarm SettingClick to apply settings and to save the set values  Alarm OutSetting Using the Web Browser 4. FTP Setting Operations Setting Using the Web BrowserViewing Still Images Viewing Live ImagesImage Link TroubleshootingSymptom Causes/Remedial Actions Displaying a still imageSpecifications OthersTemplate テンプレート 120