Preparation (Step 1 Connection/Installation)
1-4 Pull out the cables aside and mount
Settings (Step 2 Network Settings)
2-1 Installing the Software
2.
Plate for depressing cables
Power supply cable
Video signal cable
Wire clamp
4.
1.Follow steps 3 to 6 of mounting the
Camera to the Ceiling (Preparations) (☞ page 16)
2.Pass the input power cable and video signal output cable provided with the camera unit under the plate for depressing cables.
3.Follow steps 1 to 6 of mounting the
Camera to the Ceiling (Installation) (☞ page 20)
4.Bundle all the cables into the wire clamp
Bundle the cables coming out from the ceiling (Video signal cable, Input Power cable, LAN cable and alarm signal cable etc.) into the wire clamp.
5.Follow steps 7 to 8 of mounting the Camera to the Ceiling (Installation)
(☞ page 21)
6.Follow “Mounting the Camera to the
Ceiling (adjustment of the camera’s angle of view)”. (☞ page 23)
To operate this camera, you will have to install the necessary software according to
the following procedure from the
~~~~~~~~~~~~~~~~~~~
Installing the V.Networks Controller
1.Execute "Setup.exe" in the [JVC] folder.
2.Follow instructions on the screen to install the software.
3.If installation is successful, the † "V.Networks Controller" icon will be displayed in the [Start] †
[Programs] [V. NETWORKS] folder.
Installing the VN-C205U Setup Tool
1.Execute "Setup.exe". This is located inside the [Setup] folder of the [JVC] folder.
2.Follow instructions on the screen to install the software.
3.If installation is successful, the †
[Programs] [V. NETWORKS] folder.
1-5 White-spot correction
As a general characteristic unique to CCDs,
Switch on the camera power supply and wait for at least 30 minutes.
1. Remove the dome cover.
2. Cover the lens surface using a black sheet of paper, etc. so that light does not enter the lens.
3. Press and hold the SPOT CORRECTION button on the unit for more than 2 seconds.
*
Notes
•Maximum correction: less than 16 to 32 spots
•The
•When performing
•The result of
2627