Page 16 | AXIS 215 PTZ Installation Guide |
Connection diagram
AXIS 215 PTZ
12V
max. 100mA
1o
e.g. pushbutton
2o
z
3 o
4
o
LED indicators
LED | Color | Indication |
|
|
|
Network | Green | Steady for connection to a 100 Mbit/s network. Flashes for network activity. |
|
|
|
| Amber | Steady for connection to 10 Mbit/s network. Flashes for network activity. |
|
|
|
| Unlit | No network connection. |
|
|
|
Status | Green | Steady green for normal operation. |
|
|
|
| Amber | Steady during startup, during reset to factory default or when restoring settings. |
|
|
|
| Red | Slow flash for failed upgrade. |
|
|
|
Power | Green | Normal operation. |
|
|
|
| Amber | Flashes green/amber during firmware upgrade. |
|
|
|
Resetting to the Factory Default Settings
This will reset all parameters, including the IP address, to the factory default settings:
1.Disconnect power from the camera.
2.Press and hold the Control button and reconnect power.
3.Keep the Control button pressed until the Status indicator displays amber (this may take up to 15 seconds), then release the button.
4.When the Status indicator displays green (which can take up to 1 minute) the process is complete and the camera has been reset.
5.
It is also possible to reset parameters to the original factory default settings via the web interface. For more information, please see the online help or the user’s manual.