Bushnell 201965, 201966 Trouble Shooting Table, If unit does not turn on VDT does not illuminate

Page 13

TROUBLE SHOOTING TABLE

If unit does not turn on VDT™ does not illuminate:

Depress power button.

Check and if necessary, replace battery. If unit does not respond to key presses, replace the battery with a good

quality CR2 3-volt Lithium battery.

Ensure the display is on the brightest setting while in sunlight. While pressing Power Button, cover the objective lenses to determine if the display is on. See the display brightness setting instructions on Page 11.

If unit powers down (display goes blank when attempting to power the laser):

• The battery is either weak or low quality. Replace the battery with a good quality 3 -volt lithium battery (CR2).

If target range cannot be obtained:

Make sure Display is illuminated.

Make sure that the power button is being depressed.

Make sure that nothing, such as your hand or finger, is blocking the objective lenses (lenses closest to the target) that emit and receive the laser pulses.

Make sure unit is held steady while depressing power button.

NOTE: The last range reading does not need to be cleared before ranging another target. Simply aim at the new target using the display reticle, depress the power button and hold until new range reading is displayed. Specifications, instructions, and the operation of these products are subject to change without notice.

FCC Note

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Shielded interface cable must be used with the equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.

Specifications and designs are subject to change without any notice or obligation on the part of the manufacturer.

FDA SAFETY

Class 1 laser product in accordance with IEC 60825-1:2007.

Complies with 21 CFR 1040.10 and 1040.11 for laser products except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007.

Caution: There are no user controls, adjustments or procedures. Performance of procedures other than those specified herein may result in access to invisible laser light.

24

25

Image 13
Contents English Contents Introduction 201965/201966 Bushnell G-Force1300 ARC- Laser RangefinderHOW OUR Digital Technology Works Ranging AccuracyHoldover / Bullet-drop measure for Rifle Mode Operational Summary Vivid Display IndicatorsAngle Range Compensation Modes Targeting ModesInserting the Battery Battery Life IndicatorUnit of Measure Options Active LaserDisplay Brightness Flashing Setup menu Normal Operating MenuRifle Mode Example BOW Mode ExampleKnowing Which Ballistic Group to Select Regular ModePopular Caliber & Load Combinations What if your caliber is not listed? ExampleRainGuard HD CleaningNever directly on the lens Tripod Mount50827 Köln TWO-Year Limited WarrantyU.S.A. Send To Canada Send To FDA Safety Trouble Shooting TableIf unit does not turn on VDT does not illuminate If target range cannot be obtainedFrançais Fonctionnement DE Notre Technologie Numérique 201965/201966 Bushnell G-Force1300 ARC Télémètre LaserPrécision DE L’ÉVALUATION DES Distances Résumé DU Fonctionnement DE L’APPAREIL Mesure du taux de chute de balle/ report en mode fusilIndicateurs DU Vivid Display affichage Modes de compensation de la portée angulaireOptions DES Unités DE Mesure Mise EN Place DE LA PileLaser Actif Modes DE Visée Sélectifs Selective TargetingLuminosité DE L’AFFICHAGE En Mode normal Le mode TIR a L’ARC et le mode FusilExemple DE Mode TIR a L’ARC Menu Configuration Menu Fonctionnement NormalExemple DU Mode Fusil Savoir Quel Groupe Balistique Sélectionner Mode NormalCombinaisons populaires de calibre et de charge Et si votre calibre ne figure pas sur la liste? ExempleNettoyage RainGuard HD protection hydrophobeAdaptateur DE Trepied AUX ETATS-UNIS, envoyez à AU CANADA, envoyez à Garantie Limitée DE Deux ANSEn Europe, vous pouvez aussi contacter Bushnell à l’adresse Tél. +49 0 221 995 568Si la distance de la cible ne peut pas être obtenue Tableau DE DépannageSecurite FDA Español Introducción 201965/201966 Bushnell G-Force1300 ARC Telémetro LáserCómo Funciona Nuestra Tecnología Digital Precisión DE Medición DE DistanciaModos de compensación de la distancia angular Resumen Operativo Indicadores DE LA Pantalla VívidaModos de apuntar Modo de Ojo de buey Modo de MalezaOpciones DE Unidades DE Medida Inserción DE LA BateríaLáser Activo Modos DE Selective TargetingBrillo DE LA Pantalla FiguraModo de funcionamiento normal del menú de configuración CONFIGURACIÓNnormalSelección de rifle Parpadeará en la pantallaEjemplo DE Modo Rifle Ejemplo DE Modo ArcoCómo Saber QUÉ Grupo Balístico Seleccionar Modo regularCombinaciones habituales de calibre y carga ¿Qué pasa si su calibre no está listado? EjemploMenos de 20 cm Menos de 99 cmSoporte Para Trípode LimpiezaEn EE. UU., envíelo a En CANADÁ, envíelo a Garantía Limitada DE DOS AñosSi la unidad no se enciende, la pantalla VDT no se ilumina Tabla de solución de problemasSi no puede obtener el alcance del objetivo Observaciones FCCDeutsch UND SO Funktioniert Unsere Digitale Technologie EinleitungGenauigkeit DER Messung RainGuard HD-Beschichtung ausgestattetVivid DISPLAY-ANZEIGEN Zusammenfassung DER BedienungWinkel-Entfernungskompensations-Modi Ziel-ModiEinlegen DER Batterie BatterielebensdaueranzeigeAuswahl DER Messeinheit Aktiver LaserAnzeigehelligkeit AbbildungSETUP-Menü Normales Bedienungsmenü Symbol, während bei Anzeige einer Gewehr -Wahl das SymbolBlinken der Nachricht angezeigt wird Wenn angezeigt wird, blinkt die Meldung in der AnzeigeBeispiel Gewehrmodus Beispiel BogenmodusAuswahl DER Richtigen Ballistikgruppe Regulärer ModusKombinationen beliebter Kaliber und Ladungen Was, wenn Ihr Kaliber nicht aufgeführt ist? BeispielBei einem Yard 300 m 500 m STATIV-MONTAGE ReinigungOz g Beschränkte Zweijahresgarantie Servicezentrum für Europa Mathias-Brüggen-Straße 50827 KölnVersandadresse in den USA Tel. +49 0 221 995 568Wenn die Zieldistanz nicht erreicht werden kann Tabelle ZUR StörungsbehebungFCC Hinweis Sicherheit Gemäss FDAItaliano Introduzione 201965/201966 Bushnell G-Force1300 ARC Telemetro LaserDescrizione Della Tecnologia Digitale Impiegata Precisione Delle LettureModi di compensazione angolare della distanza Modalità D’USO Indicatori Vivid DisplayMisura della tenuta/caduta del proiettile nel modo Fucile Inserimento Della Pila Indicatore DI Carica BatteriaIndicazione DELL’UNITÀ DI Misura Laser Attivo107 Due modalità ARC sono la modalità Arco e la modalità Fucile Menu Setup Menu funzionamento normaleEsempio DI Modo Fucile Esempio DI Modo ArcoCome Selezionare IL Gruppo Balistico Appropriato Modo regolareCombinazioni popolari calibro e carico Il mio carico non è incluso nelle tabelle. Come fare? EsempioMeno di 20 cm Meno di 99 cmSostegno PER Treppiede PuliziaRecapito negli Stati Uniti Recapito in Canada Garanzia Limitata a DUE AnniSe il telemetro o VDT non si accende Guida Alla Soluzione DEI ProblemiSe non si riesce a misurare la distanza dal bersaglio Annotazioni FCCPortuguês Introdução 201965/201966 Bushnell G-Force1300 ARC Laser RangefinderComo Funciona a Nossa Tecnologia Digital Precisão DE MediçãoModos de Compensação de Medição em Ângulo Resumo Operacional Indicadores Vivid DisplayModos de Alvo Modo BullsEye Modo BrushInserir a Bateria Indicador do Nível DA BateriaOpções DAS Unidades DE Medida Laser ActivoFigura Luminosidade do Visor133 Exemplo EM Modo DE Arco Menu Setup Menu Operacional NormalExemplo EM Modo DE Carabina Determinar O Grupo Balístico a Seleccionar Modo NormalCombinações Populares de Calibre e Carga Se o seu calibre não se encontrar listado? ExemploMontagem Para Tripé LimpezaNos E.U.A. enviar para No Canadá enviar para Garantia Limitada DE Dois AnosCentro de serviço europeu Mathias-Brüggen-Straße 50827 Köln Telef. +49 0 221 995 568Se a unidade não ligar VDT não acende Tabela DE Resolução DE ProblemasSe não for possível obter a distância ao alvo Nota da FCCBushnell Outdoor Products 2011