Gateway 312785C ProMix 2KS Modbus/TCP Variable Map EasyKey, Units Low Limit High Limit

Page 30

Modbus and I/O Data

ProMix 2KS Modbus/TCP Variable Map

Table 4: ProMix 2KS Modbus/TCP Variable Map

 

EasyKey

 

 

 

 

 

* Read/Write

Modbus

 

 

 

 

 

Status

Register

Description

Size

Units

Low Limit

High Limit

 

 

 

 

 

 

 

Read Only

40003

Current flow rate

16 Bit

cc/min

0

5000

Read Only

40004

Actual ratio

16 Bit

none

0

9999

Read Only

40005

Active recipe

16 Bit

none

0

60

Read Only

40006

Potlife 1 remaining

16 Bit

sec

0

9999

Read/Write

40007

Job complete

16 Bit

none

0

0xFFFF

Read/Write

40008

Reset job total

16 Bit

none

0

9

Read Only

40009

Potlife 2 remaining

16 Bit

sec

0

9999

Read Only

40010

Active fault

32 Bit

none

0

0xffffffff

Read Only

40032

Control version

32 Bit

none

0

0xffffffff

Read/Write

40040

Robot digital input

16 Bit

none

0x0000

0xFFFF

Read Only

40041

Robot digital output

16 Bit

none

0x0000

0xFFFF

Read/Write

40046

New recipe

16 Bit

none

0

60

Read Only

40048

Current fluid pressure

16 Bit

psi

0

5000

Read Only

40049

V/P percent output

16 Bit

%

0

100

Read Only

**40056

Actual ratio reducer

16 Bit

none

0

9999

Read Only

40114

Flow control option

16 Bit

0=proportioning only

0

4

 

 

 

 

1=1K flow control

 

 

 

 

 

 

(future)

 

 

 

 

 

 

2=2K flow control

 

 

 

 

 

 

3=pressure override

 

 

 

 

 

 

4=manual percent

 

 

 

 

 

 

override

 

 

Read/Write

40115

Flow setpoint data source

16 Bit

0=discrete

0

1

 

 

 

 

1=network

 

 

Read/Write

40120

Manual override percent

16 Bit

%

0

100

 

 

opening

 

 

 

 

Read/Write

40125

Flow control range

16 Bit

0=0-300 cc/min

0

2

 

 

 

 

1=0-600 cc/min

 

 

 

 

 

 

2=0-1200 cc/min

 

 

Read/Write

40126

Flow control tolerance

16 Bit

%

0

99

Read/Write

40127

Flow control proportional

16 Bit

default=400

0

9999

 

 

gain Kp

 

 

 

 

Read/Write

40128

Flow control integral gain

16 Bit

default=40

0

9999

 

 

Ki

 

 

 

 

Read/Write

40129

Flow control alarm time

16 Bit

sec

0

99

Read/Write

40137

Flow control setpoint

16 Bit

cc/min

0

1200

Read/Write

43123

Flow control override

16 Bit

0=off (normal)

0

2

 

 

mode

 

1=% open

 

 

 

 

 

 

2=pressure mode

 

 

Read/Write

43141

Flow control enable

16 Bit

0=off

0

1

 

 

 

 

1=on

 

 

*This column represents the rule that must be implemented by automation. Writing to Read Only registers must be avoided.

**For ProMix 3KS Systems only.

30

312785C

Image 30
Contents Important Safety Instructions Gateway Network Communication KitsContents Graco Gateway Kits Related ManualsComponent Manuals in English Description Fire and Explosion Hazard Location Install the Gateway Module HardwareGraco Gateway Overview MountingNON-HAZARDOUS Area Connect the Module to EasyKey Cabling ConnectionsGateway Module Wiring Diagrams onEasyKey Bottom View IG EasyKey and Module Cable Connection PointsPower Connector Expansion Port RS232/PGUSB/PG Ethernet Install CompactFlash Card Mount the Control on DIN RailInstall the GracoConfig Software System RequirementsSoftware Updates Load the SoftwareDownload the Preconfigured Database to the Gateway Module Set Communications Port to USBCommunications Button Graco Gateway Network Communications ConfigurationStartup GracoConfig Main Balloon HelpSetup the Database Preconfigured DatabaseRename PLC1 Map Data Mapping Gateway BlocksSetting Block Size Block Mapping Data Stop Mix Process Modbus and I/O DataStart Mix Process Color Change ProcessStart Mix Mode Process Flow Chart Mixing Mode Process Flow Chart Purge Mode Process Flow Chart Color Change Mode Process Flow Chart Alarm Processing Alarm Processing Flow ChartModbus and I/O Data ProMix 2KS Active Alarms Modbus Register ProMix 2KS Digital Outputs Modbus RegisterBit Digital Input Binary Name Details ProMix 2KS Active Alarms Modbus Register Modbus Status Register Description ProMix 2KS Modbus/TCP Variable MapProMix 2KS Modbus/TCP Variable Map EasyKey Units Low Limit High LimitProMix 2KS Recipe Bits ProMix 2KS Recipe BitsTroubleshooting General TroubleshootingCommunication Troubleshooting See Serial Communication TrouBleshooting page 36 or Ethernet Problem Cause Solution Graco Gateway Messages Troubleshooting Serial Communication Troubleshooting Ethernet Communication Troubleshooting User Communication Ports TX/RX LEDs LED FunctionsStatus STS LED Ethernet LEDsSystem Electrical Schematic Non-Hazardous AreaParts Part No. Description QtyWiring Diagrams 417Introduction Appendix a DeviceNet Slave CommunicationOverview DeviceNet Port ProtocolsDeviceNet Port Pin Outs and PLC Connection About DeviceNet Predefined Master/Slave Connection SetLevel of Support Gateway Configuration Configure the Gateway DeviceNet Option CardHardware Select DeviceNet Server Device Settings Create Gateway Blocks Add a Gateway BlockSelect Data Type Word as Long DeviceNet Block Mapping Automatic Update of the EDS File Automatic EDS UpdateConfigure the RSNetWorx for DeviceNet Software EDS ValidationReview EDS Registration Apply and Save Configure the Allen Bradley ControlLogix PLC Create Valid DeviceNet ScannerWire the DeviceNet Network Main Task TreeAppendix B Profibus DP Slave Communication Profibus Port ProtocolsAlso see Appendix B Profibus DP Slave Communi- cation on About Profibus DP DP MasterSetup the PLC Install the GSD fileBrowse to GSD File Setup the Profibus Network DP Properties WindowOpen Profibus Properties Set Transmission Rate Add the Graco Gateway to the Profibus Network Add Graco Gateway to Profibus NetworkConfigure Data Blocks Graco Gateway Setup Setup the Profibus CommunicationSelect Profibus Server Setup Tags Create a VariableSelect Block Type How Addressing Works PLC Addressing SchemeUseful Formulas PLCAppendix C Graco Gateway to ControlLogix via Ethernet IP Ethernet PLC ConnectionControlLogix Configuration Ethernet Module PropertiesPort Configuration Window Ethernet Module Properties Ethernet Configuration Data Graco Gateway Configuration Ethernet Block SettingsAppendix C Graco Gateway to ControlLogix via Ethernet IP Dimensions Dimensions Technical Data Graco Standard Warranty Graco Information