Appendix B: ProfibusDP Slave Communication

The option card appeared in the communication tree. Select the Profibus Interface and click the Edit button to select a driver. Click OK to pick the Profibus DP driver. FIG. 60.

FIG. 60: Select Profibus Server

Graco Gateway now displays the driver settings where the Station Address can be changed. This address is the Gateway address on the Profibus network. In our example, this address is 5 as setup in the PLC earlier.

NOTE: There are no Baud Rate settings as the Profibus option card detects the transmission rate automatically.

A device called PLC1 is now displayed under the Profi- bus Interface. This device represents the Profibus Mas- ter and can be renamed to fit the application. In this example, the name PLC1 remains. FIG. 61.

FIG. 61: Block Settings

312785C

67

Image 67
Contents Gateway Network Communication Kits Important Safety InstructionsContents Related Manuals Graco Gateway KitsComponent Manuals in English Description Fire and Explosion Hazard Mounting Install the Gateway Module HardwareGraco Gateway Overview LocationNON-HAZARDOUS Area Cabling Connections Connect the Module to EasyKeyIG EasyKey and Module Cable Connection Points Wiring Diagrams onEasyKey Bottom View Gateway ModuleRS232/PG Power Connector Expansion PortUSB/PG Ethernet Mount the Control on DIN Rail Install CompactFlash CardSystem Requirements Install the GracoConfig SoftwareLoad the Software Software UpdatesSet Communications Port to USB Download the Preconfigured Database to the Gateway ModuleBalloon Help Graco Gateway Network Communications ConfigurationStartup GracoConfig Main Communications ButtonPreconfigured Database Setup the DatabaseRename PLC1 Mapping Gateway Blocks Map DataSetting Block Size Block Mapping Data Color Change Process Modbus and I/O DataStart Mix Process Stop Mix ProcessStart Mix Mode Process Flow Chart Mixing Mode Process Flow Chart Purge Mode Process Flow Chart Color Change Mode Process Flow Chart Alarm Processing Flow Chart Alarm ProcessingModbus and I/O Data ProMix 2KS Digital Outputs Modbus Register ProMix 2KS Active Alarms Modbus RegisterBit Digital Input Binary Name Details ProMix 2KS Active Alarms Modbus Register Units Low Limit High Limit ProMix 2KS Modbus/TCP Variable MapProMix 2KS Modbus/TCP Variable Map EasyKey Modbus Status Register DescriptionProMix 2KS Recipe Bits ProMix 2KS Recipe BitsGeneral Troubleshooting TroubleshootingSee Serial Communication Trou Communication TroubleshootingBleshooting page 36 or Ethernet Problem Cause Solution Graco Gateway Messages Troubleshooting Serial Communication Troubleshooting Ethernet Communication Troubleshooting Ethernet LEDs LED FunctionsStatus STS LED User Communication Ports TX/RX LEDsNon-Hazardous Area System Electrical SchematicPart No. Description Qty Parts417 Wiring DiagramsDeviceNet Port Protocols Appendix a DeviceNet Slave CommunicationOverview IntroductionDeviceNet Port Pin Outs and PLC Connection Predefined Master/Slave Connection Set About DeviceNetLevel of Support Configure the Gateway DeviceNet Option Card Gateway ConfigurationHardware Select DeviceNet Server Device Settings Add a Gateway Block Create Gateway BlocksSelect Data Type Word as Long DeviceNet Block Mapping Automatic EDS Update Automatic Update of the EDS FileEDS Validation Configure the RSNetWorx for DeviceNet SoftwareReview EDS Registration Apply and Save Create Valid DeviceNet Scanner Configure the Allen Bradley ControlLogix PLCMain Task Tree Wire the DeviceNet NetworkProfibus Port Protocols Appendix B Profibus DP Slave CommunicationAlso see Appendix B Profibus DP Slave Communi- cation on DP Master About Profibus DPInstall the GSD file Setup the PLCBrowse to GSD File DP Properties Window Setup the Profibus NetworkOpen Profibus Properties Set Transmission Rate Add Graco Gateway to Profibus Network Add the Graco Gateway to the Profibus NetworkConfigure Data Blocks Setup the Profibus Communication Graco Gateway SetupSelect Profibus Server Create a Variable Setup TagsSelect Block Type PLC Addressing Scheme How Addressing WorksPLC Useful FormulasEthernet PLC Connection Appendix C Graco Gateway to ControlLogix via Ethernet IPEthernet Module Properties ControlLogix ConfigurationPort Configuration Window Ethernet Module Properties Ethernet Configuration Data Ethernet Block Settings Graco Gateway ConfigurationAppendix C Graco Gateway to ControlLogix via Ethernet IP Dimensions Dimensions Technical Data Graco Information Graco Standard Warranty