Appendix B: ProfibusDP Slave Communication

In the popup window, select the block type required. Two

• Select the data offset, which points the address to

choices are available:

read or write in the block. Select the data type to

 

read or write. This defines how many bytes to

• Input block: The terminology input is from the Sie-

access in the block to get the correct data. In this

mens perspective. Therefore this will be a block the

example we choose output block, with data offset 0

Gateway will write to. The tag mapped to an input

(Which points to 256 in the PLC) and as a Word.

block has to be set up as Write Only.

FIG. 64.

• Output block: The terminology output is from the

 

Siemens perspective. Therefore this will be a block

 

the Gateway will read from. The tag mapped to an

 

output block has to be set up as Read Only.

 

FIG. 64: Select Block Type

NOTE: Since the output block is a reading block from the Gateway standpoint, this variable should be set up as Read Only as shown in Fig. 19. The same rule applies if the block is an input block, it should be set up as Write Only.

To avoid mistakes, the mapping shows with an R or W for output or input block respectively. FIG. 65.

FIG. 65: Properties of Variable

312785C

69

Image 69
Contents Gateway Network Communication Kits Important Safety InstructionsContents Graco Gateway Kits Related ManualsComponent Manuals in English Description Fire and Explosion Hazard Graco Gateway Overview Install the Gateway Module HardwareLocation MountingNON-HAZARDOUS Area Cabling Connections Connect the Module to EasyKeyEasyKey Bottom View Wiring Diagrams onGateway Module IG EasyKey and Module Cable Connection PointsRS232/PG Power Connector Expansion PortUSB/PG Ethernet Mount the Control on DIN Rail Install CompactFlash CardSystem Requirements Install the GracoConfig SoftwareLoad the Software Software UpdatesSet Communications Port to USB Download the Preconfigured Database to the Gateway ModuleStartup GracoConfig Main Graco Gateway Network Communications ConfigurationCommunications Button Balloon HelpPreconfigured Database Setup the DatabaseRename PLC1 Mapping Gateway Blocks Map DataSetting Block Size Block Mapping Data Start Mix Process Modbus and I/O DataStop Mix Process Color Change ProcessStart Mix Mode Process Flow Chart Mixing Mode Process Flow Chart Purge Mode Process Flow Chart Color Change Mode Process Flow Chart Alarm Processing Flow Chart Alarm ProcessingModbus and I/O Data ProMix 2KS Active Alarms Modbus Register ProMix 2KS Digital Outputs Modbus RegisterBit Digital Input Binary Name Details ProMix 2KS Active Alarms Modbus Register ProMix 2KS Modbus/TCP Variable Map EasyKey ProMix 2KS Modbus/TCP Variable MapModbus Status Register Description Units Low Limit High LimitProMix 2KS Recipe Bits ProMix 2KS Recipe BitsGeneral Troubleshooting TroubleshootingCommunication Troubleshooting See Serial Communication TrouBleshooting page 36 or Ethernet Problem Cause Solution Graco Gateway Messages Troubleshooting Serial Communication Troubleshooting Ethernet Communication Troubleshooting Status STS LED LED FunctionsUser Communication Ports TX/RX LEDs Ethernet LEDsNon-Hazardous Area System Electrical SchematicPart No. Description Qty Parts417 Wiring DiagramsOverview Appendix a DeviceNet Slave CommunicationIntroduction DeviceNet Port ProtocolsDeviceNet Port Pin Outs and PLC Connection About DeviceNet Predefined Master/Slave Connection SetLevel of Support Gateway Configuration Configure the Gateway DeviceNet Option CardHardware Select DeviceNet Server Device Settings Add a Gateway Block Create Gateway BlocksSelect Data Type Word as Long DeviceNet Block Mapping Automatic EDS Update Automatic Update of the EDS FileEDS Validation Configure the RSNetWorx for DeviceNet SoftwareReview EDS Registration Apply and Save Create Valid DeviceNet Scanner Configure the Allen Bradley ControlLogix PLCMain Task Tree Wire the DeviceNet NetworkAppendix B Profibus DP Slave Communication Profibus Port ProtocolsAlso see Appendix B Profibus DP Slave Communi- cation on DP Master About Profibus DPInstall the GSD file Setup the PLCBrowse to GSD File DP Properties Window Setup the Profibus NetworkOpen Profibus Properties Set Transmission Rate Add Graco Gateway to Profibus Network Add the Graco Gateway to the Profibus NetworkConfigure Data Blocks Setup the Profibus Communication Graco Gateway SetupSelect Profibus Server Create a Variable Setup TagsSelect Block Type PLC Addressing Scheme How Addressing WorksPLC Useful FormulasEthernet PLC Connection Appendix C Graco Gateway to ControlLogix via Ethernet IPEthernet Module Properties ControlLogix ConfigurationPort Configuration Window Ethernet Module Properties Ethernet Configuration Data Ethernet Block Settings Graco Gateway ConfigurationAppendix C Graco Gateway to ControlLogix via Ethernet IP Dimensions Dimensions Technical Data Graco Information Graco Standard Warranty