Gateway 312785C important safety instructions Modbus and I/O Data

Page 27

Modbus and I/O Data

Table 1: ProMix 2KS Digital Inputs (Modbus Register 40040)

Bit

Digital Input Binary

 

 

 

 

 

 

 

Name

Details

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0:5

0

0

0

0

0

0

0

0

0

0

X

X

X

X

X

X

Recipe

Binary bits for viewing discrete inputs only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

0

0

0

0

0

0

0

0

0

1

0

0

0

0

0

0

Color Change

Set bit to “1” to initiate Color Change (momentary)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(CC)

 

7

0

0

0

0

0

0

0

0

1

0

0

0

0

0

0

0

Mix

Set bit initiate Mix mode (maintain)

8

0

0

0

0

0

0

0

1

0

0

0

0

0

0

0

0

Purge

Set bit to “1” to initiate Purge sequence (maintained)

9

0

0

0

0

0

0

1

0

0

0

0

0

0

0

0

0

Job_Complete

Set bit to “1” to initiate Job Complete input (momen-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tary)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

0

0

0

0

0

1

0

0

0

0

0

0

0

0

0

0

External CC

Set bit to “1” to initiate External Color Change

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ready

(momentary)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

0

0

0

0

1

0

0

0

0

0

0

0

0

0

0

0

Not Used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

0

0

0

1

0

0

0

0

0

0

0

0

0

0

0

0

FC _Calibrate

Set bit to “1” to initiate a Flow Control Calibrate input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(momentary)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

0

0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

Gun_Trigger

Set bit to “1” to indicate the gun is actually triggered

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(maintain while gun is triggered, remove when gun is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

closed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Reset_Alarm

Set bit to “1” to clear an active Alarm (momentary)

15

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Remote Stop

Set bit to remotely stop unit (momentary)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Shaded cells relate to the flow charts on pages 23-26.

312785C

27

Image 27
Contents Gateway Network Communication Kits Important Safety InstructionsContents Graco Gateway Kits Related ManualsComponent Manuals in English Description Fire and Explosion Hazard Mounting Install the Gateway Module HardwareGraco Gateway Overview LocationNON-HAZARDOUS Area Cabling Connections Connect the Module to EasyKeyIG EasyKey and Module Cable Connection Points Wiring Diagrams onEasyKey Bottom View Gateway ModuleRS232/PG Power Connector Expansion PortUSB/PG Ethernet Mount the Control on DIN Rail Install CompactFlash CardSystem Requirements Install the GracoConfig SoftwareLoad the Software Software UpdatesSet Communications Port to USB Download the Preconfigured Database to the Gateway ModuleBalloon Help Graco Gateway Network Communications ConfigurationStartup GracoConfig Main Communications ButtonPreconfigured Database Setup the DatabaseRename PLC1 Mapping Gateway Blocks Map DataSetting Block Size Block Mapping Data Color Change Process Modbus and I/O DataStart Mix Process Stop Mix ProcessStart Mix Mode Process Flow Chart Mixing Mode Process Flow Chart Purge Mode Process Flow Chart Color Change Mode Process Flow Chart Alarm Processing Flow Chart Alarm ProcessingModbus and I/O Data ProMix 2KS Active Alarms Modbus Register ProMix 2KS Digital Outputs Modbus RegisterBit Digital Input Binary Name Details ProMix 2KS Active Alarms Modbus Register Units Low Limit High Limit ProMix 2KS Modbus/TCP Variable MapProMix 2KS Modbus/TCP Variable Map EasyKey Modbus Status Register DescriptionProMix 2KS Recipe Bits ProMix 2KS Recipe BitsGeneral Troubleshooting TroubleshootingCommunication Troubleshooting See Serial Communication TrouBleshooting page 36 or Ethernet Problem Cause Solution Graco Gateway Messages Troubleshooting Serial Communication Troubleshooting Ethernet Communication Troubleshooting Ethernet LEDs LED FunctionsStatus STS LED User Communication Ports TX/RX LEDsNon-Hazardous Area System Electrical SchematicPart No. Description Qty Parts417 Wiring DiagramsDeviceNet Port Protocols Appendix a DeviceNet Slave CommunicationOverview IntroductionDeviceNet Port Pin Outs and PLC Connection About DeviceNet Predefined Master/Slave Connection SetLevel of Support Gateway Configuration Configure the Gateway DeviceNet Option CardHardware Select DeviceNet Server Device Settings Add a Gateway Block Create Gateway BlocksSelect Data Type Word as Long DeviceNet Block Mapping Automatic EDS Update Automatic Update of the EDS FileEDS Validation Configure the RSNetWorx for DeviceNet SoftwareReview EDS Registration Apply and Save Create Valid DeviceNet Scanner Configure the Allen Bradley ControlLogix PLCMain Task Tree Wire the DeviceNet NetworkAppendix B Profibus DP Slave Communication Profibus Port ProtocolsAlso see Appendix B Profibus DP Slave Communi- cation on DP Master About Profibus DPInstall the GSD file Setup the PLCBrowse to GSD File DP Properties Window Setup the Profibus NetworkOpen Profibus Properties Set Transmission Rate Add Graco Gateway to Profibus Network Add the Graco Gateway to the Profibus NetworkConfigure Data Blocks Setup the Profibus Communication Graco Gateway SetupSelect Profibus Server Create a Variable Setup TagsSelect Block Type PLC Addressing Scheme How Addressing WorksPLC Useful FormulasEthernet PLC Connection Appendix C Graco Gateway to ControlLogix via Ethernet IPEthernet Module Properties ControlLogix ConfigurationPort Configuration Window Ethernet Module Properties Ethernet Configuration Data Ethernet Block Settings Graco Gateway ConfigurationAppendix C Graco Gateway to ControlLogix via Ethernet IP Dimensions Dimensions Technical Data Graco Information Graco Standard Warranty