Modbus and I/O Data
Table 1: ProMix 2KS Digital Inputs (Modbus Register 40040)
Bit | Digital Input Binary |
|
|
|
|
|
|
| Name | Details | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0:5 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | X | X | X | X | X | X | Recipe | Binary bits for viewing discrete inputs only. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | Color Change | Set bit to “1” to initiate Color Change (momentary) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (CC) |
|
7 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Mix | Set bit initiate Mix mode (maintain) |
8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Purge | Set bit to “1” to initiate Purge sequence (maintained) |
9 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Job_Complete | Set bit to “1” to initiate Job Complete input (momen- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| tary) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | External CC | Set bit to “1” to initiate External Color Change |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ready | (momentary) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
11 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Not Used |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | FC _Calibrate | Set bit to “1” to initiate a Flow Control Calibrate input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (momentary) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
13 | 0 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Gun_Trigger | Set bit to “1” to indicate the gun is actually triggered |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (maintain while gun is triggered, remove when gun is |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| closed) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
14 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Reset_Alarm | Set bit to “1” to clear an active Alarm (momentary) |
15 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Remote Stop | Set bit to remotely stop unit (momentary) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: Shaded cells relate to the flow charts on pages
312785C | 27 |