Gateway 312785C important safety instructions Fire and Explosion Hazard

Page 4

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

• Use equipment only in well ventilated area.

• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

ELECTRIC SHOCK HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu- facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

4

312785C

Image 4
Contents Important Safety Instructions Gateway Network Communication KitsContents Related Manuals Graco Gateway KitsComponent Manuals in English Description Fire and Explosion Hazard Install the Gateway Module Hardware Graco Gateway OverviewLocation MountingNON-HAZARDOUS Area Connect the Module to EasyKey Cabling ConnectionsWiring Diagrams on EasyKey Bottom ViewGateway Module IG EasyKey and Module Cable Connection PointsPower Connector Expansion Port RS232/PGUSB/PG Ethernet Install CompactFlash Card Mount the Control on DIN RailInstall the GracoConfig Software System RequirementsSoftware Updates Load the SoftwareDownload the Preconfigured Database to the Gateway Module Set Communications Port to USBGraco Gateway Network Communications Configuration Startup GracoConfig MainCommunications Button Balloon HelpSetup the Database Preconfigured DatabaseRename PLC1 Map Data Mapping Gateway BlocksSetting Block Size Block Mapping Data Modbus and I/O Data Start Mix ProcessStop Mix Process Color Change ProcessStart Mix Mode Process Flow Chart Mixing Mode Process Flow Chart Purge Mode Process Flow Chart Color Change Mode Process Flow Chart Alarm Processing Alarm Processing Flow ChartModbus and I/O Data ProMix 2KS Digital Outputs Modbus Register ProMix 2KS Active Alarms Modbus RegisterBit Digital Input Binary Name Details ProMix 2KS Active Alarms Modbus Register ProMix 2KS Modbus/TCP Variable Map ProMix 2KS Modbus/TCP Variable Map EasyKeyModbus Status Register Description Units Low Limit High LimitProMix 2KS Recipe Bits ProMix 2KS Recipe BitsTroubleshooting General TroubleshootingSee Serial Communication Trou Communication TroubleshootingBleshooting page 36 or Ethernet Problem Cause Solution Graco Gateway Messages Troubleshooting Serial Communication Troubleshooting Ethernet Communication Troubleshooting LED Functions Status STS LEDUser Communication Ports TX/RX LEDs Ethernet LEDsSystem Electrical Schematic Non-Hazardous AreaParts Part No. Description QtyWiring Diagrams 417Appendix a DeviceNet Slave Communication OverviewIntroduction DeviceNet Port ProtocolsDeviceNet Port Pin Outs and PLC Connection Predefined Master/Slave Connection Set About DeviceNetLevel of Support Configure the Gateway DeviceNet Option Card Gateway ConfigurationHardware Select DeviceNet Server Device Settings Create Gateway Blocks Add a Gateway BlockSelect Data Type Word as Long DeviceNet Block Mapping Automatic Update of the EDS File Automatic EDS UpdateConfigure the RSNetWorx for DeviceNet Software EDS ValidationReview EDS Registration Apply and Save Configure the Allen Bradley ControlLogix PLC Create Valid DeviceNet ScannerWire the DeviceNet Network Main Task TreeProfibus Port Protocols Appendix B Profibus DP Slave CommunicationAlso see Appendix B Profibus DP Slave Communi- cation on About Profibus DP DP MasterSetup the PLC Install the GSD fileBrowse to GSD File Setup the Profibus Network DP Properties WindowOpen Profibus Properties Set Transmission Rate Add the Graco Gateway to the Profibus Network Add Graco Gateway to Profibus NetworkConfigure Data Blocks Graco Gateway Setup Setup the Profibus CommunicationSelect Profibus Server Setup Tags Create a VariableSelect Block Type How Addressing Works PLC Addressing SchemeUseful Formulas PLCAppendix C Graco Gateway to ControlLogix via Ethernet IP Ethernet PLC ConnectionControlLogix Configuration Ethernet Module PropertiesPort Configuration Window Ethernet Module Properties Ethernet Configuration Data Graco Gateway Configuration Ethernet Block SettingsAppendix C Graco Gateway to ControlLogix via Ethernet IP Dimensions Dimensions Technical Data Graco Standard Warranty Graco Information