Gateway 312785C Graco Gateway Network Communications Configuration, Startup GracoConfig Main

Page 15

Graco Gateway Network Communications Configuration

Graco Gateway Network Communications Configuration

Startup

GracoConfig Main Page

To run GracoConfig, select the icon

from the

Graco folder on the Programs section of your Start Menu. The main page will appear, showing the Commu- nications button.

Communications Button

FIG. 17: Communications Button

Communications Button

The Communications button provides access to screens used to configure your system and setup parameters, allowing you to:

Specify which protocols are to be used on the Gate- way serial ports and on the Ethernet port.

If using master protocols (ie., protocols by which the Gateway initiates data transfer to and from a remote device), you can specify one or more devices to be accessed.

If using slave protocols (i.e., protocols by which the Gateway receives and responds to requests from remote devices or computer systems), you can set read or write access for specific data items.

Move data between one remote device and another.

Balloon Help

The Balloon Help feature allows you to see help infor- mation for each icon in the main menu, or for each field

in a dialog box or window. It is controlled via the

icon at the right-hand edge of the toolbar. Balloon Help has three user-selectable modes:

Do Not Display disables balloon help

When Mouse Over displays help when the mouse pointer is held over a particular field for a certain period of time

When Selected displays help constantly for the cur- rently selected field.

312785C

15

Image 15
Contents Gateway Network Communication Kits Important Safety InstructionsContents Graco Gateway Kits Related ManualsComponent Manuals in English Description Fire and Explosion Hazard Mounting Install the Gateway Module HardwareGraco Gateway Overview LocationNON-HAZARDOUS Area Cabling Connections Connect the Module to EasyKeyIG EasyKey and Module Cable Connection Points Wiring Diagrams onEasyKey Bottom View Gateway ModuleRS232/PG Power Connector Expansion PortUSB/PG Ethernet Mount the Control on DIN Rail Install CompactFlash CardSystem Requirements Install the GracoConfig SoftwareLoad the Software Software UpdatesSet Communications Port to USB Download the Preconfigured Database to the Gateway ModuleBalloon Help Graco Gateway Network Communications ConfigurationStartup GracoConfig Main Communications ButtonPreconfigured Database Setup the DatabaseRename PLC1 Mapping Gateway Blocks Map DataSetting Block Size Block Mapping Data Color Change Process Modbus and I/O DataStart Mix Process Stop Mix ProcessStart Mix Mode Process Flow Chart Mixing Mode Process Flow Chart Purge Mode Process Flow Chart Color Change Mode Process Flow Chart Alarm Processing Flow Chart Alarm ProcessingModbus and I/O Data ProMix 2KS Active Alarms Modbus Register ProMix 2KS Digital Outputs Modbus RegisterBit Digital Input Binary Name Details ProMix 2KS Active Alarms Modbus Register Units Low Limit High Limit ProMix 2KS Modbus/TCP Variable MapProMix 2KS Modbus/TCP Variable Map EasyKey Modbus Status Register DescriptionProMix 2KS Recipe Bits ProMix 2KS Recipe BitsGeneral Troubleshooting TroubleshootingCommunication Troubleshooting See Serial Communication TrouBleshooting page 36 or Ethernet Problem Cause Solution Graco Gateway Messages Troubleshooting Serial Communication Troubleshooting Ethernet Communication Troubleshooting Ethernet LEDs LED FunctionsStatus STS LED User Communication Ports TX/RX LEDsNon-Hazardous Area System Electrical SchematicPart No. Description Qty Parts417 Wiring DiagramsDeviceNet Port Protocols Appendix a DeviceNet Slave CommunicationOverview IntroductionDeviceNet Port Pin Outs and PLC Connection About DeviceNet Predefined Master/Slave Connection SetLevel of Support Gateway Configuration Configure the Gateway DeviceNet Option CardHardware Select DeviceNet Server Device Settings Add a Gateway Block Create Gateway BlocksSelect Data Type Word as Long DeviceNet Block Mapping Automatic EDS Update Automatic Update of the EDS FileEDS Validation Configure the RSNetWorx for DeviceNet SoftwareReview EDS Registration Apply and Save Create Valid DeviceNet Scanner Configure the Allen Bradley ControlLogix PLCMain Task Tree Wire the DeviceNet NetworkAppendix B Profibus DP Slave Communication Profibus Port ProtocolsAlso see Appendix B Profibus DP Slave Communi- cation on DP Master About Profibus DPInstall the GSD file Setup the PLCBrowse to GSD File DP Properties Window Setup the Profibus NetworkOpen Profibus Properties Set Transmission Rate Add Graco Gateway to Profibus Network Add the Graco Gateway to the Profibus NetworkConfigure Data Blocks Setup the Profibus Communication Graco Gateway SetupSelect Profibus Server Create a Variable Setup TagsSelect Block Type PLC Addressing Scheme How Addressing WorksPLC Useful FormulasEthernet PLC Connection Appendix C Graco Gateway to ControlLogix via Ethernet IPEthernet Module Properties ControlLogix ConfigurationPort Configuration Window Ethernet Module Properties Ethernet Configuration Data Ethernet Block Settings Graco Gateway ConfigurationAppendix C Graco Gateway to ControlLogix via Ethernet IP Dimensions Dimensions Technical Data Graco Information Graco Standard Warranty