Sterling 6017 series installation manual Identifying System Status Board Indicators, Alarm Silence

Page 41

Alarm Silence

Press the ALARM SILENCE button to silence the audible alarm on the console.

!CAUTION

After you silence the alarm, make sure you locate and correct the alarm condition before continuing with unit operation.

5-5 Identifying System Status Board Indicators

The system status board is located next to the controller panel. It displays indicator lights to show current operation status, letting you analyze system performance.

Figure 6

System Status Board Indicators

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM STATUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PUMP OVERLOAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER ON

 

 

 

 

 

PUMP REVERSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

PUMP FORWARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BYPASS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELIEF VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DELIVERY

 

 

 

 

 

PRESSURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAFETY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STRAINER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXCHANGER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN

 

 

 

 

LEVEL

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SOLENOID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FILL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

 

 

 

VENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRAIN

 

 

 

RES.

LEVEL

 

 

SOLENOID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TANK

6017 Series Hot Oil Large Temperature Control Units

Page 41

Image 41
Contents $30.00 Series Large Hot Oil Temperature Control UnitsSeries Hot Oil Large Temperature Control Units Safety Considerations Table of Contents Startup Preparations Charts and Figures Necessary Documents IntroductionModels Covered Standard FeaturesImmersion Heaters Feature DescriptionsAvailable Options Ful-Flo Valve Heater TankPump Optional CoolingConnection Lines Electrical System Controls Air Purge Electrical Panel and System ComponentsReservoir Tank Pressure SwitchSafety Thermostat Series Hot Oil Large Temperature Control Units 50 kW 100 kW 150 kW 200 kW 90 gpm 150 gpm 200 gpm Lbs Event of Shipping Damages Unpacking and InspectionReturns If the Shipment is Not CompleteIf the Shipment is Not Correct Work Rules Installation RequirementsInstallation Location Considerations Connecting Piping Customer is responsible for conversions to metric standards Piping Considerations for Mobile InstallationsConnecting Vent Piping Connecting Process PipingConnecting Cooling Water Piping Series Hot Oil Large Temperature Control Units Typical Flow Schematic Custom Process Piping Making Electrical Connections Series Hot Oil Large Temperature Control Units Series Hot Oil Large Temperature Control Units Starting the Unit Startup PreparationsUnit START-UP with Autovent Solenoid Series Hot Oil Large Temperature Control Units Returning Fluid to the Tank Shutting Down the UnitSeries Hot Oil Large Temperature Control Units Microprocessor Controller Using Controls and IndicatorsDisplay Indicators Status IndicatorsIdentifying M2B Controller Panel Components Screen DisplaysAlarm Indicators Motor Fail Indicator Using M2B Controller KeysSET Point Key UP Arrow KeyEnter Key Index Key Alarm HI Alarm Key Alarm LO Alarm KeyDigital Flow Screen Identifying Control Panel SwitchesDisplay Key Pump Start Mode SelectPump Stop Vent Cycle Start optionalAlarm Silence Identifying System Status Board IndicatorsMode Indicator Lights Status Indicator LightsAuto Mode Indicator Light Fault Indicator LightsPump Overload Indicator Light Low Pressure Indicator LightLow Level Indicator Light High Level Indicator LightSeries Hot Oil Large Temperature Control Units Making Monthly Checks Periodic ChecksMaking Daily Checks Making Six-Month Checks Routine ServicingMaking Quarterly Checks Servicing the Unit Every Three Months Servicing the Unit Monthly or Every 500 HoursMotor Lubrication Procedure Pumps and Seals Corrective MaintenanceSeries Hot Oil Large Temperature Control Units Troubleshooting Check the heater output with an Service Notes Service Notes Service Notes Parts Department Technical Assistance