5.0 DFS - 1 ERROR CODES
ERROR CODES FOR ON-BOARD DISPLAY
The
0 | All conditions nominal |
|
1 | Undervoltage trip | Line voltage dropped below minimum level |
2 | Overvoltage trip of drive | Bus voltage exceeded safe limit |
3 | Undervoltage timer tripped | Line voltage low for too long |
4 | Instantaneous overcurrent | Excessive transistor current |
5 | Loss of encoder signal | Encoder speed signals lost. |
|
| Encoder loss detection applies only when pulse |
|
| multiplier is set to 4X |
6 | Motor thermal tripped | Motor is too hot or thermal is disconnected |
7 | Commutation fault | Signals from position encoder lost |
8 | +24VDC lost at | Fuse FR1 overloaded |
9 | +24VDC lost at | Fuse FR2 overloaded |
A | +5VDC lost at | Fuse FR4 overloaded |
B | +24VDC lost at | Fuse FR3 overloaded |
C | Current limit | Drive is at maximum current output |
D | Timed Overload | Timed overcurrent has occured |
E | Display fault | Fault in display module |
F | Applications fault | Fault in applications program |
Revised 7/95 | Page 43 | |