DCS BFG-308S, BFG-308GD, BFG-30G manual Gas Hook-Up, GAS Requirement

Page 18

INSTALLATION

GAS HOOK-UP

GAS REQUIREMENT

Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the appliance rating plate agrees with that of the supply. The rating plate is located on the bottom of the outdoor appliance. Never connect an unregulated gas line to the appliance. You must use the gas regulator provided with the unit even if the supply is controlled.

An installer-supplied gas shut-off valve must be installed in an easily accessible location. All installer supplied parts must conform to local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CAN/CGA-B149.1 Natural Gas Installation Code or CAN/CGA-B149.2 Propane Installation Code.

All pipe sealants must be an approved type and resistant to the actions of LP gases. Never use pipe sealant on flare fittings. All gas connections should be made by a qualified technician and in accordance with local codes and ordinances. In the absence of local codes, the installation must comply with the National Fuel Gas Code, ANSI Z223.1. Gas conversion kits are available from the factory. When ordering gas conversion kits, have the model number, and the type of gas (natural or LP) from your outdoor appliance.

TOTAL GAS CONSUMPTION OF THE OUTDOOR APPLIANCE WITH ALL BURNERS ON HI/ SEAR:

BFG-30G - 50,000 Btu/hr

BFG-30BGD - 49,000 Btu/hr

BFG-30BS - 34,000 Btu/hr

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa.) The appliance must be iso- lated from the gas supply piping system by closing its individual manual shut-off valve during any pressure test- ing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa.). The installation of this appliance must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1. Installation in Canada must be in accordance with the Standard Can1-b149.1 and/or .2 (installation code for gas burning appliances and equipment) and

local codes.

NATURAL GAS HOOK UP: (THIS TYPE OF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTION SHOULD BE PERFORMED BY A

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED OR LICENSED TECHNICIAN ONLY.)

 

 

 

 

 

 

 

 

 

 

 

Connection: 1/2” NPT male with 3/8” flare adapter.

 

 

 

 

 

 

 

Bottom of unit

 

Operating pressure: 4.0” W.C. Supply pressure: 5”

 

 

 

 

 

 

 

 

 

 

Coupling

to 14” water column. If in excess of 14” W.C., a step-

 

 

 

 

 

Threading compound

 

 

 

 

 

 

down regulator is required. Check with your local

 

 

 

 

 

1/2” NPT x

 

 

 

 

 

must be resistant to LP gas

gas utility company or local codes for instructions on

 

 

 

 

 

 

 

 

 

 

2.0”

 

 

 

 

 

 

 

 

 

 

Nipple

installing gas supply lines. Be sure to check on type

 

 

 

 

 

 

 

 

 

 

Regulator

and size of run, and how deep to bury the line. If the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2” NPT x 5.0”

4.0" W.C.

gas line is too small, the outdoor appliance will not

 

 

 

 

 

 

 

 

 

 

 

Nipple

 

function properly. Any joint sealant used must be

 

 

 

 

 

 

 

 

 

 

Adapter 1/2” NPT

an approved type and be resistive to the actions of

Installer supplied shut-off

to 3/8” flare fitting

 

natural gases.

valve must be easily

Do not put threading

 

accessible*

compound on these

TO HOOK-UP THE FITTINGS SUPPLIED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

threads

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WITH THE OUTDOOR APPLIANCE:

 

 

 

 

 

*Installation must conform with local

 

 

 

 

 

 

 

 

 

 

Assemble as shown (Fig. 22). Use threading com-

 

 

 

 

 

codes or with the National Fuel Gas Code

pound on male threads only. Do not use threading

 

 

 

 

 

ANSI Z223.1 or the CAN/CGA-B149.2

 

 

 

 

 

Propane Installation Code

 

compound on the male end of the 1/2” NPT to 3/8

 

 

 

 

 

 

 

 

 

 

 

flare adapter. Use a second pipe wrench to hold the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

outdoor appliance inlet pipe to avoid shifting any

 

 

 

 

 

Fig. 22 Natural Gas

 

internal gas lines of the outdoor appliance. Ensure

 

 

 

 

 

 

 

 

 

 

 

that the regulator arrow points in the direction of gas

 

 

 

 

 

 

 

 

 

 

 

flow towards the unit, away from the supply. Do not forget to place the installer-supplied gas valve in an acces- sible location.

16

Image 18
Contents Professional Liberty Collection Page Message to OUR Customers Please Retain this Manual for Future ReferenceContents Safety Practices & Precautions Important Safety NoticeOutdoor Appliance Placement Safety Practices & Precautions Outdoor Appliance Models Before Using Your Appliance BFG-30G All-GrillInstallation Locating Outdoor APPLIANCE/BUILT-IN ClearancesLocation Locating BUILT-IN Clearances GeneralInsulated Jacket BUILT-IN Construction Details Standard layout for non-combustible enclosureCart Assembly Instructions Locating the CartStep Outdoor Appliance Head Preparation Pinch Point Gas Hookup LP Cover HangerGAS HOOK-UP GAS RequirementLP GAS Hook UP Type 1 or QCC1 Regulator LP Tank RequirementsLP Tank Restraint for BUILT-IN Installation 18 maxStep Leak Testing GRILL/GRIDDLE Unit Before TestingBurner Efficiency and Flame Characteristics Leak Testing Side BurnerBurner Adjustment Side Burner Flame HeightBurner Adjustment GRILL/GRIDDLE Unit LOW Setting AdjustmentOutdoor Appliance Burner Flame Height Radiant Assembly Radiant Assembly InstallationFaucet Installation Sink InstallationSink Side Shelf Optional accessory Check List These InstructionsUsing the Grill Lighting InstructionsUSE of the Grill Important Using the Grill Grilling HintsUsing the Side Burner Match LightingThermocouple Using the GriddleBefore Using the Griddle for the First Time or To RE-SEASON USE of the GriddleUsing the Griddle Using the Sink Regulator and Hose Replacement Care and MaintenanceBattery Replacement Cleaning Grill GratesStainless Steel Grill Burner CleaningCeramic Rods Grill BurnerOrifice Cleaning Side Burner GrateSide Burners Side Burner Electrodes Control KnobsSink Troubleshooting Outdoor Appliance Before Calling for ServiceProblem What to do Troubleshooting Side Burner Service HOW to Obtain ServiceHOW Long does the Limited Warranty LAST? WarrantyLimited Warranty This Warranty does not CoverHOW to GET Service Commercial USENo Other Warranties Page LA Collection Professionnelle Liberty ’INTENTION DE NOS Clients Veuillez Conserver CE Manuel À Titre DE RéférenceTable DES Matières Utilisation DE LA Plaque ChauffantePage Mesures DE Sécurité ET DE Précaution Emplacement ’APPAREIL D’EXTÉRIEUR Hauteur deRemaque Modèles D’APPAREILS D’EXTÉRIEUR Avant D’UTILISER L’APPAREIL BFG-30G Tout grilEmplacement DE L’APPAREIL D’EXTÉRIEUR ET DES Dégagements EmplacementEmplacement DES Dégagements GénéralitésEnveloppe Isolée Détails D’UNE Construction Intégrée Disposition standard pour une enceinte non combustiblePlacement DE LA Desserte Instructions DE Montage DE ChariotÉtape Préparation de la tête de l’appareil d’extérieur Points DE Pincement Branchement du gaz Propane AccrochezBranchement DU GAZ Exigences Concernant LE GAZPour Connecter LES Raccords Fournis Avec LE Gril Branchement DU Propane Régulateur DE Type 1 OU QCC1 Exigences Concernant LA Bouteille DE Propane45,7 cm 18 po Max Placez le dispositif de retenue de bouteille dans l’îlot Fig Avant la vérification Brûleurs Test DE Détection DES Fuites Brûleur LatérauxRéglage DES Brûleur Brûleur Latéraux Efficacité DES Brûleurs ET Caractéristiques DE LA FlammeHauteur DES Flammes DU Brûleur DU Gril Réglages Pour Niveau BASInstallation DE L’ENSEMBLE DU Radiant Installation DE L’ENSEMBLE DU RadiantInstallation DES Robinets Installation DE L’ÉVIERÉvier Tablette Latérale accessoire en option Liste DE Contrôle DE L’INSTALLATEUR Veuillez LaisUtilisation DU Gril Utilisation DU GrilInstructions D’ALLUMAGE Important Utilisation du gril Conseils AU Sujet DU GrilUtilisation DU Drûleur Latéral Allumage À L’ALLUMETTEUtilisation DE LA Plaque Chauffante Utilisation DE LA Plaque ChauffanteTableau DE Cuisson DE LA Plaque Chauffante Utilisation DE LA Plaque Chauffante Utilisation DE L’ÉVIER Entretien ET Nettoyage Remplacement DE LA PileRemplacement DU Régulateur ET DU Tuyau Nettoyage DES Grilles DU GrilAcier Inoxydable Entretien ET MaintenanceTiges EN Céramique Brûleur DU GrilNettoyage DE L’ORIFICE Grille DU Brûleur LatéralBoutons DE Réglage Électrodes DE Brûleurs LatérauxPlaque Chauffante ÉvierAvant D’APPELER LE Service Technique Problème SolutionDépannage Appareil D’EXTÉRIEUR Dépannage Brûleur Latéral Pour L’OBTENTION DU Service DE Garantie Fisher & Paykel S’ENGAGE À GarantieGarantie Limitée Quelle EST LA Durée DE LA Garantie LIMITÉE?Pour Obtenir DES Réparations Utilisation CommercialeAucune Autre Garantie Remarque Remarque Remarque Page Litho in USA 09/2001