Advanced Micro-Fuel Cell, designed for percent oxygen analysis. Several options are available.

Versatile analysis over a wide range of applications.

Microprocessor based electronics: 8-bit CMOS microprocessor with 32 kB RAM and 128 kB ROM.

Three user definable output ranges (from 0-1% through 0-100 %) allow best match to users process and equipment.

Air-calibration range for convenient spanning at 20.9 %.

Auto Ranging allows analyzer to automatically select the proper preset range for a given measurement. Manual override allows the user to lock onto a specific range of interest.

Two adjustable concentration alarms and a system failure alarm.

Extensive self-diagnostic testing, at startup and on demand, with continuous power-supply monitoring.

Two way RFI protection.

RS-232 serial digital port for use with a computer or other digital communication device.

Analog outputs for percent-of-range and for range identification. 0–1 V dc. (Isolated 4–20 mA dc optional)

Convenient and versatile, steel, flush-panel or rack-mountable case with slide-out electronics drawer.

1.4Model Designations

3000PA: Standard model.

3000PA-C:In addition to all standard features, this model also has separate ports for zero and span gases, and built-in control valves. The internal valves are entirely under the control of the 3000PA electronics, to automatically switch between gases in synchronization with the analyzer’s operations.

3000PA-M:This model has current output signals (4-20 mA) for percent- of-range and range ID, in addition to voltage outputs.

3000PA-S:A Stainless Steel Probe and Probe Holder are used in this model, for use where resistance to corrosion is important.

1-2

Teledyne Analytical Instruments

Image 8
Contents Model 3000PA Model 3000PA Teledyne Analytical InstrumentsInstrument Serial Number Includes the following options IiiPercent Oxygen Analyzer Specific Model Information Model 3000PA Table of Contents Introduction InstallationOperationalTheory OperationAppendix MaintenancePercent Oxygen Analyzer Combustible GAS Usage Warning Main Features of the Analyzer OverviewTypical Applications Percent Oxygen Analyzer IntroductionModel Designations Introduction Model 3000PAFront Panel Operator Interface Model 3000PA Front PanelIntroduction Model 3000PA Analog Outputs Recognizing Difference Between LCDRear Panel Equipment Interface RS-232 Port Remote ProbeNetwork OptionalOperational Theory Introduction Micro-Fuel Cell SensorPercent Oxygen Analyzer Operational Theory Principles of OperationOperational Theory Model 3000PA Anatomy of a Micro-Fuel CellElectrochemical Reactions + 2H O + 4e → 4OHCalibration Characteristics Effect of PressureClass A-5 Cell Micro-Fuel Cell ClassClass A-3 Cell Hydrogen and/or Helium Service Sample SystemClass B-1 Cell Class B-3 CellPiping Layout and Flow Diagram for Standard Model Electronics and Signal Processing Span Zero SampleBlock Diagram of the Model 3000P Electronics Operational Theory Model 3000PA Mounting the Analyzer Percent Oxygen Analyzer InstallationUnpacking the Analyzer Installation Model 3000PA Rear Panel ConnectionsGas Connections Rear Panel of the Model 3000PAElectrical Connections Percent Oxygen Analyzer Installation Teledyne Analytical Instruments Percent Oxygen Analyzer Installation Command Description Parameter Setting Remote Probe ConnectorInstalling the Micro-Fuel Cell Testing the SystemPercent Oxygen Analyzer Operation Auto Ranging onUsing the Data Entry and Function Buttons Operation Model 3000PASystem Function Hierarchy of Functions and SubfunctionsSetting the Display Percent Oxygen Analyzer Operation Setting up an Auto-Cal Password ProtectionEntering the Password Installing or Changing the Password Logout Version Screen Span Functions Cell FailureAuto Mode Spanning Span CalAlarms Function Manual Mode SpanningInstallation AL-1 AL-2 Choose Alarm Setting the Analog Output Ranges Range FunctionOperation Model 3000PA Autoranging Analysis Fixed Range AnalysisAnalyze Function Signal OutputVoltage Signal Current Signal Output V dc Output mA dc Range Voltage Current mA Routine Maintenance Cell ReplacementPercent Oxygen Analyzer Maintenance Storing and Handling Replacement CellsMaintenance Model 3000P When to Replace a CellIndex Removing the Micro-Fuel CellRemoving or Installing a Micro-Fuel Cell Cell Warranty Fuse Replacement System Self Diagnostic TestPower Major Internal ComponentsAnalog PreampCleaning Rear-Panel ScrewsPossible Cause TroubleshootingSolution Maintenance Model 3000P Teledyne Analytical Instruments Model 3000PA Specifications Percent Oxygen Analyzer AppendixAppendix Model 3000PA Recommended 2-Year Spare Parts List Qty Part Number DescriptionDrawing List 19-inch Relay Rack Panel MountSeries Analyzers Calibration GAS Conversions Zero Cal ZeroSettlingMan ENT To Begin