Teledyne 3000PA operating instructions Major Internal Components, Power, Analog, Preamp

Page 57

Percent Oxygen Analyzer

Maintenance 5

 

 

 

 

 

 

 

 

 

Table 5-1: Self Test Failure Codes

Power

0OK

15 V Failure

215 V Failure

3Both Failed

Analog

0OK

1DAC A (0–1 V Concentration)

2DAC B (0–1 V Range ID)

3Both Failed

Preamp

0OK

1Zero too high

2Amplifier output doesn't match test input

3Both Failed

5.5Major Internal Components

The Micro-Fuel cell is accessed by unlatching and swinging open the front panel, as described earlier. Other internal components are accessed by removing the rear panel and sliding out the entire chassis. See Figure 5-4, below. The gas piping is illustrated in Figure 2-4, and the major electronic components locations are shown in Figure 2-5, in chapter 2.

WARNINGS: See warnings on the title page of this manual.

The 3000PA contains the following major components:

• Analysis Section

Micro Fuel Cell (B-1 standard—others available)

Nylon Probe and Holder

Sample System

Power Supply

Microprocessor

Displays

5 digit LED meter

2 line, 20 character, alphanumeric, VFD display

RS-232 Communications Port.

See the drawings in the Drawings section in back of this manual for details.

Teledyne Analytical Instruments

5-7

Image 57
Contents Model 3000PA Teledyne Analytical Instruments Model 3000PAIii Percent Oxygen Analyzer Specific Model InformationInstrument Serial Number Includes the following options Installation Model 3000PA Table of Contents IntroductionOperationalTheory OperationMaintenance Percent Oxygen AnalyzerAppendix Combustible GAS Usage Warning Overview Main Features of the AnalyzerTypical Applications Percent Oxygen Analyzer IntroductionIntroduction Model 3000PA Model DesignationsModel 3000PA Front Panel Front Panel Operator InterfaceIntroduction Model 3000PA Recognizing Difference Between LCD Rear Panel Equipment InterfaceAnalog Outputs Remote Probe RS-232 PortNetwork OptionalMicro-Fuel Cell Sensor Operational Theory IntroductionPercent Oxygen Analyzer Operational Theory Principles of OperationAnatomy of a Micro-Fuel Cell Operational Theory Model 3000PA+ 2H O + 4e → 4OH Electrochemical ReactionsEffect of Pressure Calibration CharacteristicsMicro-Fuel Cell Class Class A-3 CellClass A-5 Cell Sample System Hydrogen and/or Helium ServiceClass B-1 Cell Class B-3 CellPiping Layout and Flow Diagram for Standard Model Span Zero Sample Electronics and Signal ProcessingBlock Diagram of the Model 3000P Electronics Operational Theory Model 3000PA Percent Oxygen Analyzer Installation Unpacking the AnalyzerMounting the Analyzer Rear Panel Connections Installation Model 3000PARear Panel of the Model 3000PA Gas ConnectionsElectrical Connections Percent Oxygen Analyzer Installation Teledyne Analytical Instruments Percent Oxygen Analyzer Installation Command Description Remote Probe Connector Parameter SettingTesting the System Installing the Micro-Fuel CellAuto Ranging on Percent Oxygen Analyzer OperationOperation Model 3000PA Using the Data Entry and Function ButtonsHierarchy of Functions and Subfunctions System FunctionSetting the Display Password Protection Percent Oxygen Analyzer Operation Setting up an Auto-CalEntering the Password Installing or Changing the Password Logout Version Screen Cell Failure Span FunctionsSpan Cal Auto Mode SpanningManual Mode Spanning Alarms FunctionInstallation AL-1 AL-2 Choose Alarm Range Function Setting the Analog Output RangesFixed Range Analysis Operation Model 3000PA Autoranging AnalysisSignal Output Voltage Signal Current Signal Output V dc Output mA dcAnalyze Function Range Voltage Current mA Cell Replacement Routine MaintenancePercent Oxygen Analyzer Maintenance Storing and Handling Replacement CellsWhen to Replace a Cell Maintenance Model 3000PRemoving the Micro-Fuel Cell IndexRemoving or Installing a Micro-Fuel Cell Cell Warranty System Self Diagnostic Test Fuse ReplacementMajor Internal Components PowerAnalog PreampRear-Panel Screws CleaningTroubleshooting SolutionPossible Cause Maintenance Model 3000P Teledyne Analytical Instruments Percent Oxygen Analyzer Appendix Model 3000PA SpecificationsAppendix Model 3000PA Qty Part Number Description Recommended 2-Year Spare Parts List19-inch Relay Rack Panel Mount Drawing ListSeries Analyzers Calibration GAS Conversions Zero Cal ZeroSettlingMan ENT To Begin