BATTERIES/CHARGING
PROCEDURE 4 | BATTERIES/CHARGING | |
|
|
|
WARNING
NEVER allow any of your tools and/or battery cables to contact BOTH terminal(s) post(s) at the same time. An electrical short may occur and injury or damage may occur.
The use of rubber gloves and chemical goggles is recommended when working with batteries.
CAUTION
When tightening the clamps, always use a box or a crescent wrench. Pliers will “round off” the nuts. NEVER wiggle the terminal when tighten- ing. The battery may become damaged.
1.Remove the batteries with cable assemblies from scooter. Refer to REMOVING/ INSTALLING THE BATTERIES WITH CABLES in this procedure of the manual.
2.If necessary, lift battery cable boot up off of the battery terminal.
3.For
4.For all other models, remove the hardware that secures the cable assembly to the battery terminals. Hardware for each model is as follows:
A.For LYNX
B.For LYNX
C.For PANTHER
5.Repeat STEPS 2 - 4 for opposite battery.
6.Position battery cables onto NEW battery terminals.
CAUTION
The positive (+) terminal MUST be connected to the positive (+) termi- nal/post, otherwise serious damage will occur to the electrical system.
WARNING
Always make black cable to negative terminal connection first. Other- wise,
injury may result.
A.BLACK Cable to NEGATIVE
B.RED Cable to POSITIVE (+) Terminal.
7.Secure battery cable to the battery terminals:
A.For
B.For LYNX
C.For LYNX
D.For PANTHER
Invacare Scooters | 28 | Part No. 1090132 Rev F |