Chapter 2: Devices and Services

neCluster",0,"","",0,"",3,0,0,1,"6076",5362499,1273883641,541,2954,487,2849,6,96 ,144,"03d4df7b-78ff-460e-a0bb- 43ccee36cc5f","Phones","StandAloneCluster","SEP00155832DDD5","MLQK=3.2000;MLQKav =3.3000;MLQKmn=1.4000;MLQKmx=3.9000;ICR=0.8200;CCR=0.7600;ICRmx=0.9800;CS=9;SCS= 2;MLQKvr=;z="

1,1,8590499,10263919,1273883642,1,0,760260611,"6058","termine",0,1,4,0,0,51,0,0,

0,0,0,0,0,"0","0",19835742,0,0,0,"6017","6017","",0,0,4,0,0,0,0,0,0,0,0,0,0,"0", "0",0,1273883642,"6001","593fa05e-bc1d-4dc5-9cca- 6c25184e7e98","","Phones","","",197,"SEP00155832DDD6","",13,0,0,0,0,0,0,"StandAl oneCluster",0,"","",0,"",3,0,0,1,"6058",10263919,1273883642,128,313,1784,1107,11 ,176,62,"03d4df7b-78ff-460e-a0bb- 43ccee36cc5f","Phones","StandAloneCluster","SEP00155832DDD5","MLQK=3.2000;MLQKav =3.3000;MLQKmn=1.4000;MLQKmx=3.9000;ICR=0.8200;CCR=0.7600;ICRmx=0.9800;CS=9;SCS= 2;MLQKvr=;z="

This example contains both the CDR and CMR data, with the CMR data concatenated to the end of the CDR line. This example is taken from the output file after the Cisco IP Telephony Technology Pack has processed the two inputs and created the CSV file for the UBA.

Bulk adaptor design files

Tivoli Netcool/Proviso supports several data formats for bulk input files, including CSV, XML, and binary. Each UBA technology pack provides a Bulk Adaptor Design File to define the data format supported by that technology pack. The Bulk Adaptor Design File, which is a JavaScript file, processes both inventory and statistics data from the same bulk input file. The Bulk Adaptor Design File provides a function that creates the bulk collection formula names. Some technology packs provide several Bulk Adaptor Design Files, each of which handles a specific bulk input file format.

The Cisco IP Telephony Technology Pack provides the following Bulk Adaptor Design Files:

CCMAdaptor.js

CCMConfig.js

CCMSupport.js

CUCMAdaptor.js

CUCMConfig.js

CUCMPerfmonAdaptor.js

CUCMSupport.js

IBM Tivoli Netcool/Proviso Cisco IP Telephony 2.4.0.0 Technology Pack

11

Image 15
Contents IBM Copyright IBM Corp Contents Contents Organization AudienceTivoli Netcool/Proviso documentation Tivoli Netcool/Proviso product suiteSummary of Device Technology OverviewCategories of Service Reporting Source of Collected Data Collection Type Sources of Collected DataPort for SQL Access Troubleshooting Note for SQL RequestsDevices and Services Prerequisites Snmp AccessBulk input file formats Supported MIBsBulk input file name Bulk input file schemaBulk adaptor design files Devices and Services Reporter sets Supported Reports and KPIsReporter set summary Reporter set tree Reporter set contents Cluster Quality Resource Cluster Call Distribution ResourceCluster Call Distribution Group Top 10 Cluster Call Completion Cluster Quality GroupCluster Utilization Group Cluster IP vs Legacy Resource Top 10 Cluster Number of ErrorsTop 10 Cluster Number of Calls Cluster VoiceMail Usage ResourceCDR Quality Resource Cluster Utilization MLH ResourceCluster Erlang-B Group Extension CDR Utilization ResourceTop 10 CDR Number of Errors CDR Call Distribution ResourceTop 10 CDR Number of Calls CDR Quality Group CDR VoiceMail Usage ResourceTop 10 CDR Call Completion Top 10 CDR Call DurationCDR Call Distribution Group Factor Factor ResourceFactor Group Top 10 CDR K-Factor Codec Errors on Cluster by CodecCallManager Server CCM Server Quality Resource CCM Sql Server ResourceCCM Sql Server Group Device Pstn Gateway Device Quality Resource Pstn Gateway Interface Top 10 E1/T1 Utilization ResourcePstn Gateway E1/T1Availability Resource Pstn Gateway E1/T1 Interface Utilization ResourceMedia Device Group Pstn Gateway Availability ResourceDSP Card Pstn Gateway DSP Card Resource Media Devices Media Device ResourceGatekeeper Device Quality Resource Gatekeeper Availability Resource Gatekeeper Availability Resource Detail ChartPerfmon Perfmon Active Calls Resource Gatekeeper Interface Utilization Resource Detail ChartGatekeeper Interface Availability Resource Gatekeeper Interface Utilization ResourcePerfmon Active Calls Group Perfmon Security GroupPerfmon Security Resource Perfmon MOH Group Perfmon Pstn ResourcePerfmon Pstn Group Perfmon MOH ResourceKey performance indicators Key performance indicatorsCCR Supported Reports and KPIs Key performance indicators ClusterLocalCall Key performance indicators ICR Unknown or unsupported protocol Mlqk MOS SCS Key performance indicators Before you begin Configuring the technology packCd /opt/datamart Configure the technology packOpt/datamart/dataMart.env Pvm YourDataSource1 Driver=PVmsss20.so Generates output from a CDR file and its associated CMR file If true, ProvisoCUCM requests CDR and CMR data from the Cucm Request DataChannel host that requested them Report navigation by customer Name you pass to the object Tivoli Netcool/Proviso v4.4.3 and later Where Datachannelhome Specifies the channel number for example, 1 that you Success message Meaning Syntax item Verifying resources Device.instance.schema.parametername Value InstancesDescription ComponentVoipciscoipt Instances VOIPCISCOIPT.CCMINPUT.DELETEONACQUIRE VOIPCISCOIPT.CCMINPUT.URI VOIPCISCOIPT.CDRINPUT.DELETEONACQUIRE VOIPCISCOIPT.CDRINPUT.URI VOIPCISCOIPT.DESIGNFILE VOIPCISCOIPT.DESIGNFILE VOIPCISCOIPT.INPUTDIRECTORY VOIPCISCOIPT.INPUTDIRECTORY VOIPCISCOIPT.INPUTFTPPASSWORD VOIPCISCOIPT.INPUTFTPUSERNAME VOIPCISCOIPT.INPUTHOST VOIPCISCOIPT.INPUTHOST VOIPCISCOIPT.INPUTUSESECUREFTP VOIPCISCOIPT.INPUTUSESECUREFTP VOIPCISCOIPTPERFMON.DESIGNFILE VOIPCISCOIPTPERFMON.INPUTDIRECTORY VOIPCISCOIPTPERFMON.INPUTFTPPASSWORD VOIPCISCOIPTPERFMON.INPUTFTPUSERNAME VOIPCISCOIPTPERFMON.INPUTHOST VOIPCISCOIPTPERFMON.INPUTUSESECUREFTP VOIPCISCOIPTPERFMON.PERFMON.DELETEONACQUIRE VOIPCISCOIPTPERFMON.PERFMON.URI Pack-specific UBA parameters Template file name and locationUBA Parameter Value Meaning Additional information about UBA parametersDbusername URIExample UBA.1.101.VOIPCISCOIPT.CCMINPUT.DELETEONACQUIRE=false Page Page Trademarks Copyright IBM Corp Page Tcl 8.3.3, Combat/TCL 0.7.3, Combat/TCL 0.7.5, TclX 8.3, TK Additional Copyright InformationAdditional Copyright information Scotty 2.8, incrTCL 3.0, incr TCL BLT 2.4uUCD Snmp Regex 1.1a JdomXwpick Page IBM