IBM R2E2 manual Specifies the channel number for example, 1 that you

Page 63

Chapter 4: Configuring the technology pack

15.Ensure that the bulk input files can be read.

To verify that the UBA application can read the bulk input files, follow these steps:

15-a. Place a bulk input file at the source input location.

(Tivoli Netcool/Proviso v4.4.3 and later) The source input location for bulk input files is specified using the URI parameter from the pack XSD file, which you can view using the Topology Editor.

(Tivoli Netcool/Proviso pre-v4.4.3 only) using the URI parameter from the template

The source input location for bulk input files is specified file, which you added to the dc.cfg file in a previous step.

Within the configured file retrieval interval (typically, five minutes), the UBA application retrieves the bulk input file and copies it to the following directory:

DATA_CHANNEL_HOME/UBA.<channel>.<collector>/<instance>/do/

where:

Variable

Meaning

DATA_CHANNEL_HOME

Is /opt/datachannel, by default.

 

 

<channel>

Specifies the channel number (for example, 1) that you

 

specified when configuring this DataChannel.

 

 

<collector>

Specifies the collector number (for example, 100) that you

 

specified when configuring this UBA bulk collector.

 

 

<instance> (Tivoli Netcool/Proviso v4.4.3 and later)

Specifies the string for the INSTANCES parameter in the

 

pack XSD file. Typically, this string represents the name of

 

the pack and is read-only. You can view the string specified

 

for INSTANCES by using the Topology Editor.

 

 

<instance> (Tivoli Netcool/Proviso pre-v4.4.3 only)

Specifies the string for the INSTANCES parameter in the

 

pack template file. You were instructed to copy this

 

parameter to the dc.cfg file in a previous step.

The UBA application then processes the bulk input file according to the instructions in the Bulk Adaptor Design File.

Note: The first time that the UBA processes a bulk input file, it passes a metric to the CME. The CME rejects this metric as a BAD_METRIC because the metric does not have an associated grouped subelement prior to the time this metric is recorded. This is expected behavior. The CME accepts metrics from the bulk input files after the inventory is run.

15-b. Ensure that the UBA application can successfully read the bulk input file that you copied into the source input location, by issuing a tail command similar to the following example:

tail -f DATA_CHANNEL_HOME/log/proviso.log grep UBA.<channel>.<collector>- more

The following table identifies the success messages that you should look for.

IBM Tivoli Netcool/Proviso Cisco IP Telephony 2.4.0.0 Technology Pack

59

Image 63
Contents IBM Copyright IBM Corp Contents Contents Organization AudienceTivoli Netcool/Proviso documentation Tivoli Netcool/Proviso product suiteSummary of Device Technology OverviewCategories of Service Reporting Source of Collected Data Collection Type Sources of Collected DataPort for SQL Access Troubleshooting Note for SQL RequestsDevices and Services Prerequisites Snmp AccessBulk input file formats Supported MIBsBulk input file name Bulk input file schemaBulk adaptor design files Devices and Services Reporter sets Supported Reports and KPIsReporter set summary Reporter set tree Reporter set contents Cluster Quality Resource Cluster Call Distribution ResourceCluster Call Distribution Group Top 10 Cluster Call Completion Cluster Quality GroupCluster Utilization Group Cluster IP vs Legacy Resource Top 10 Cluster Number of ErrorsTop 10 Cluster Number of Calls Cluster VoiceMail Usage ResourceCDR Quality Resource Cluster Utilization MLH ResourceCluster Erlang-B Group Extension CDR Utilization ResourceTop 10 CDR Number of Errors CDR Call Distribution ResourceTop 10 CDR Number of Calls CDR Quality Group CDR VoiceMail Usage ResourceTop 10 CDR Call Completion Top 10 CDR Call DurationCDR Call Distribution Group Factor Factor ResourceFactor Group Top 10 CDR K-Factor Codec Errors on Cluster by CodecCallManager Server CCM Server Quality Resource CCM Sql Server ResourceCCM Sql Server Group Device Pstn Gateway Device Quality Resource Pstn Gateway Interface Top 10 E1/T1 Utilization ResourcePstn Gateway E1/T1Availability Resource Pstn Gateway E1/T1 Interface Utilization ResourceMedia Device Group Pstn Gateway Availability ResourceDSP Card Pstn Gateway DSP Card Resource Media Devices Media Device ResourceGatekeeper Device Quality Resource Gatekeeper Availability Resource Gatekeeper Availability Resource Detail ChartPerfmon Perfmon Active Calls Resource Gatekeeper Interface Utilization Resource Detail ChartGatekeeper Interface Availability Resource Gatekeeper Interface Utilization ResourcePerfmon Active Calls Group Perfmon Security GroupPerfmon Security Resource Perfmon MOH Group Perfmon Pstn ResourcePerfmon Pstn Group Perfmon MOH ResourceKey performance indicators Key performance indicatorsCCR Supported Reports and KPIs Key performance indicators ClusterLocalCall Key performance indicators ICR Unknown or unsupported protocol Mlqk MOS SCS Key performance indicators Before you begin Configuring the technology packCd /opt/datamart Configure the technology packOpt/datamart/dataMart.env Pvm YourDataSource1 Driver=PVmsss20.so Generates output from a CDR file and its associated CMR file If true, ProvisoCUCM requests CDR and CMR data from the Cucm Request DataChannel host that requested them Report navigation by customer Name you pass to the object Tivoli Netcool/Proviso v4.4.3 and later Where Datachannelhome Specifies the channel number for example, 1 that you Success message Meaning Syntax item Verifying resources Device.instance.schema.parametername Value InstancesDescription ComponentVoipciscoipt Instances VOIPCISCOIPT.CCMINPUT.DELETEONACQUIRE VOIPCISCOIPT.CCMINPUT.URI VOIPCISCOIPT.CDRINPUT.DELETEONACQUIRE VOIPCISCOIPT.CDRINPUT.URI VOIPCISCOIPT.DESIGNFILE VOIPCISCOIPT.DESIGNFILE VOIPCISCOIPT.INPUTDIRECTORY VOIPCISCOIPT.INPUTDIRECTORY VOIPCISCOIPT.INPUTFTPPASSWORD VOIPCISCOIPT.INPUTFTPUSERNAME VOIPCISCOIPT.INPUTHOST VOIPCISCOIPT.INPUTHOST VOIPCISCOIPT.INPUTUSESECUREFTP VOIPCISCOIPT.INPUTUSESECUREFTP VOIPCISCOIPTPERFMON.DESIGNFILE VOIPCISCOIPTPERFMON.INPUTDIRECTORY VOIPCISCOIPTPERFMON.INPUTFTPPASSWORD VOIPCISCOIPTPERFMON.INPUTFTPUSERNAME VOIPCISCOIPTPERFMON.INPUTHOST VOIPCISCOIPTPERFMON.INPUTUSESECUREFTP VOIPCISCOIPTPERFMON.PERFMON.DELETEONACQUIRE VOIPCISCOIPTPERFMON.PERFMON.URI Pack-specific UBA parameters Template file name and locationUBA Parameter Value Meaning Additional information about UBA parametersDbusername URIExample UBA.1.101.VOIPCISCOIPT.CCMINPUT.DELETEONACQUIRE=false Page Page Trademarks Copyright IBM Corp Page Tcl 8.3.3, Combat/TCL 0.7.3, Combat/TCL 0.7.5, TclX 8.3, TK Additional Copyright InformationAdditional Copyright information Scotty 2.8, incrTCL 3.0, incr TCL BLT 2.4uUCD Snmp Regex 1.1a JdomXwpick Page IBM