Xantrex Technology 809-0912 manual Typical Xanbus System Diagram

Page 14

FSequence IPM Owners Guide.book Page 4 Thursday, October 6, 2011 3:33 PM

Introduction

Xanbus System

The Xanbus system includes the Freedom SW Series Inverter/Charger and other Xanbus-enabled devices. The inverter/charger is the device in a Xanbus system that typically provides network power—500 mA at 12 volts DC. When Freedom Sequence is present in the network, it can also provide the power for the whole Xanbus network. All of the Xanbus-enabled devices, such as Freedom Sequence, the SCP, and the AGS are able to communicate their settings and activity to each other. See Figure 1.

The Xanbus-enabled designation (see below) means that this product works on a Xanbus network. Xanbus-enabled products are:

Simple to operate and routine tasks are automated,

Controlled by software that eliminates analog signalling errors,

Less susceptible to interference and line loss, and

Upgradable through new software releases.

Shore

Power

SystemAutomatic

ControlGenerator

PanelStart

Freedom Sequence

AC Panel

 

BATTERY

 

3012

 

SW

 

FREEDOM

Freedom SW Inverter/Charger

Inverter

Load Panel

 

For detailed instructions and a complete list of Xanbus-enabled devices, visit www.xantrex.com.

network

terminator

Generator

AC Loads

network

terminator

Figure 1 Typical Xanbus System Diagram

 

 

4

 

 

Freedom Sequence Intelligent Power Manager Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 14
Contents Freedom Sequence Page Contact Information About This Guide Purpose Conventions UsedRelated Information Important Safety Instructions ReferencePrecautions When Placing the Power Manager Explosion HazardRisk of Damage to the Power Manager FCC Information to the UserContents Page Standard Features IntroductionMaterial List Compatible Products and Accessories1 Product/Accessory Product NumberTypical Xanbus System Diagram Xanbus SystemMechanical Features Ports and TerminalsTypical RV Wiring Typical RV Wiring Diagram With Freedom SequencePower Manager Configuration EnterFuncPower Manager Configuration Cont Circuit StatusCircuit Status Circuit Status Config Basic Configuration SettingsList of configurable settings includes Priority List of circuit configurable settings includesCircuit Config Mode To change the Mode from the Device Status screenMode OperatingAuto Shore Breaker ModeSHR BKR Mode Manual30.0A Breaker RatingsShore Breaker Rating 25.0ARestore Defaults Restore DefaultsTo Restore Defaults from the Device Status screen Circuit Priority Circuit ConfigurationConfig Circuit To change the priority setting from the Device Status screen Config Circuit ConfigTo change the Load Shed from the Device Status screen EnabledLoad Shed Load ShedAdvanced Settings Improper Configuration DUE to Lack of ExperienceBKR Derating List of advanced settings includeAdvanced Settings Config Advanced Settings Breaker DeratingGenerator Breaker Rating Generator Warmup DelayGEN Warmup Delay Screen10sec Connect Sequence DelayConnect Seq Delay AC Disqualification Priority AC Disc Priority12.0V DC Voltage SettingNom DC Voltage Circuit Name Circuit Level Advanced SettingsCircuit2 AC Relay Settings DC Relay SettingsCircuit Name Circuit3Circuit Type AC LinePriority Generator Soft StartBattery Voltage Triggers Reconnect MarginAuto-Detection of AC Input Source Type 1-Ph/2-Ph Freedom Sequence Operational ConceptsAuto-Detection of AC Input Source Shore/Gen Loading of Shore/Generator Breaker RatingsAC Load Shedding LINE1 L1 LINE2 L2 Using DC Relay to control AC load circuits DC Load SheddingPriority Swapping Between Circuits Override the AC Circuit Load Shedding Freedom Sequence Interaction with Other Xanbus Devices Battery Voltage MeasurementGenerator Run Detection B+ Signal Freedom SW Interactive Charger De-rating ICDFreedom Sequence SCP Menu Map Specifications Warranty and Return Information WarrantyWarranty and Return Information Disclaimer ProductReturn Procedure Return Material Authorization PolicyOut of Warranty Service Information About Your System Page Xantrex Technology USA Inc