Xantrex Technology 809-0912 manual To change the priority setting from the Device Status screen

Page 28

FSequence IPM Owners Guide.book Page 18 Thursday, October 6, 2011 3:33 PM

Basic Configuration Settings

AC Relays

To change the priority setting from the Device Status screen:

By default, each AC load circuit is assigned a priority number in the factory

 

 

FSPM 00: Config

 

(ACLoad1 = 1 up to ACLoad6 = 61), which can be changed via SCP on the

FSPM 00: Status

 

 

Circuit Config screen. The priority order is then automatically swapped

L2 Amps

On 0.0A

Mode

[Operating]

 

as explained in “Priority Swapping Between Circuits” on page 37.

Batt Voltage

12.8V

SHR BKR Mode

[Manual]

Circuit Status

 

SHR BKR Rating

[25.0A]

How the power manager uses the priority number to determine the load-

Config

 

Circuit Config

 

 

 

 

 

shedding order of AC circuits is explained in “AC Load Shedding” on page

 

 

 

 

34.

 

 

 

 

 

2 Press to activate

1 Press down until the

4 Press to display 3 Scroll down until Circuit

 

the screen.

field is selected.

the screen.

Config is selected.

DC Relays

DC Relays are not assigned a priority, but if a DC relay is associated to either Line1 or Line2, it will assume the lowest priority ranking in the system.

If association of a DC Relay is changed from Line1 or Line2 to Batt1, it will lose any priority value and the power manager will re-organize the priority numbers for the rest of the relays.

FSPM 00: Circuit ConfigFSPM 00: Circuit Config

1

ACLoad1

 

1

ACLoad1

 

1

Priority

[1]

1

Priority

[*1]

1

Load Shed

[Disabled]

1

Load Shed

[Disabled]

2

ACLoad2

 

2

ACLoad2

 

 

6 Press to

5 Scroll up or down to select a

 

8 Press to

7 Scroll up and down to

 

change.

circuit priority setting.

 

confirm the

choose a value.

 

 

 

selected value.

FSPM 00: Circuit Config

 

 

 

1

ACLoad1

 

 

 

 

1

Priority

[2]

 

 

 

1

Load Shed

[Disabled]

 

 

 

2

ACLoad2

 

 

 

 

1.For the four-circuit Freedom Sequence model, AC circuits are ACLoad1 up to ACLoad4. DC circuits are from DCLoad1 up to DCLoad4.

 

 

18

 

Freedom Sequence Intelligent Power Manager Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 28
Contents Freedom Sequence Page Contact Information About This Guide Purpose Conventions UsedRelated Information Important Safety Instructions ReferencePrecautions When Placing the Power Manager Explosion HazardRisk of Damage to the Power Manager FCC Information to the UserContents Page Standard Features IntroductionMaterial List Compatible Products and Accessories1 Product/Accessory Product NumberTypical Xanbus System Diagram Xanbus SystemMechanical Features Ports and TerminalsTypical RV Wiring Typical RV Wiring Diagram With Freedom SequencePower Manager Configuration EnterFuncPower Manager Configuration Circuit Status Circuit StatusCont Circuit Status List of configurable settings includes Basic Configuration SettingsConfig Circuit Config List of circuit configurable settings includesPriority To change the Mode from the Device Status screen ModeMode OperatingShore Breaker Mode SHR BKR ModeAuto ManualBreaker Ratings Shore Breaker Rating30.0A 25.0ATo Restore Defaults from the Device Status screen Restore DefaultsRestore Defaults Config Circuit Circuit ConfigurationCircuit Priority To change the priority setting from the Device Status screen Config Circuit ConfigEnabled Load ShedTo change the Load Shed from the Device Status screen Load ShedAdvanced Settings Improper Configuration DUE to Lack of ExperienceAdvanced Settings List of advanced settings includeBKR Derating Config Advanced Settings Breaker DeratingGenerator Warmup Delay GEN Warmup DelayGenerator Breaker Rating ScreenConnect Seq Delay Connect Sequence Delay10sec AC Disqualification Priority AC Disc PriorityNom DC Voltage DC Voltage Setting12.0V Circuit2 Circuit Level Advanced SettingsCircuit Name AC Relay Settings DC Relay SettingsCircuit Name Circuit3Circuit Type AC LinePriority Generator Soft StartBattery Voltage Triggers Reconnect MarginFreedom Sequence Operational Concepts Auto-Detection of AC Input Source Shore/GenAuto-Detection of AC Input Source Type 1-Ph/2-Ph Loading of Shore/Generator Breaker RatingsAC Load Shedding LINE1 L1 LINE2 L2 Using DC Relay to control AC load circuits DC Load SheddingPriority Swapping Between Circuits Override the AC Circuit Load Shedding Battery Voltage Measurement Generator Run Detection B+ SignalFreedom Sequence Interaction with Other Xanbus Devices Freedom SW Interactive Charger De-rating ICDFreedom Sequence SCP Menu Map Specifications Warranty and Return Information WarrantyWarranty and Return Information Disclaimer ProductOut of Warranty Service Return Material Authorization PolicyReturn Procedure Information About Your System Page Xantrex Technology USA Inc