Freedom Sequence Operational Concepts

Override the AC Circuit Load Shedding

The Freedom Sequence power manager provides a feature to override the load shed priority (Load Shed setting) for an AC load circuit that was disconnected by either an AC relay or a DC relay. This allows the user the flexibility to force an AC load to turn On for just a few minutes without the need to change the priority order of all AC load circuits. When an AC load circuit’s Load Shed setting is Disabled, the power manager will skip this circuit from the load shed sequence and treat it as a non-controlled AC load on the system.

IMPORTANT: When reprogramming default circuit priority settings, always consult a professional installer from your RV dealership.

 

 

38

 

Freedom Sequence Intelligent Power Manager Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 48
Contents Freedom Sequence Page Contact Information About This Guide Purpose Conventions UsedRelated Information Important Safety Instructions ReferencePrecautions When Placing the Power Manager Explosion HazardRisk of Damage to the Power Manager FCC Information to the UserContents Page Standard Features IntroductionMaterial List Compatible Products and Accessories1 Product/Accessory Product NumberTypical Xanbus System Diagram Xanbus SystemMechanical Features Ports and TerminalsTypical RV Wiring Typical RV Wiring Diagram With Freedom SequencePower Manager Configuration EnterFuncPower Manager Configuration Circuit Status Circuit StatusCont Circuit Status Basic Configuration Settings List of configurable settings includesConfig List of circuit configurable settings includes Circuit ConfigPriority To change the Mode from the Device Status screen ModeMode OperatingShore Breaker Mode SHR BKR ModeAuto ManualBreaker Ratings Shore Breaker Rating30.0A 25.0ARestore Defaults To Restore Defaults from the Device Status screenRestore Defaults Circuit Configuration Config CircuitCircuit Priority To change the priority setting from the Device Status screen Config Circuit ConfigEnabled Load ShedTo change the Load Shed from the Device Status screen Load ShedAdvanced Settings Improper Configuration DUE to Lack of ExperienceList of advanced settings include Advanced SettingsBKR Derating Config Advanced Settings Breaker DeratingGenerator Warmup Delay GEN Warmup DelayGenerator Breaker Rating ScreenConnect Sequence Delay Connect Seq Delay10sec AC Disqualification Priority AC Disc PriorityDC Voltage Setting Nom DC Voltage12.0V Circuit Level Advanced Settings Circuit2Circuit Name AC Relay Settings DC Relay SettingsCircuit Name Circuit3Circuit Type AC LinePriority Generator Soft StartBattery Voltage Triggers Reconnect MarginFreedom Sequence Operational Concepts Auto-Detection of AC Input Source Shore/GenAuto-Detection of AC Input Source Type 1-Ph/2-Ph Loading of Shore/Generator Breaker RatingsAC Load Shedding LINE1 L1 LINE2 L2 Using DC Relay to control AC load circuits DC Load SheddingPriority Swapping Between Circuits Override the AC Circuit Load Shedding Battery Voltage Measurement Generator Run Detection B+ SignalFreedom Sequence Interaction with Other Xanbus Devices Freedom SW Interactive Charger De-rating ICDFreedom Sequence SCP Menu Map Specifications Warranty and Return Information WarrantyWarranty and Return Information Disclaimer ProductReturn Material Authorization Policy Out of Warranty ServiceReturn Procedure Information About Your System Page Xantrex Technology USA Inc