Advanced Settings
FSPM 00: Status
L2 Amps | 0.0A | |
Batt Voltage | 12.8V | |
Circuit Status |
| |
|
| |
Config |
|
|
Enter | Func |
| 1 |
To enable the selection of Advanced Settings, press the Enter, Up, and Down arrow buttons (1) simultaneously from the Device Status screen.
FSPM 00: Status
Batt Voltage | 12.8V |
Circuit Status
Config
Advanced Settings
EnterFunc
32
Once the Advanced Settings item appears from the Device Status screen, scroll down (2) until Advanced Settings is highlighted then, Press Enter (3) to bring up the Advanced Settings screen.
FSPM 00: Advanced Settings
|
|
|
BKR Derating |
| [Enabled] |
GEN BKR Rating |
| [30.0A] |
GEN Warmup Delay | [0sec] |
Connect Seq Delay [10sec]
EnterFunc
4
To activate a specific Advanced Settings item, move through each item using the Up and Down buttons (4). When a selection is made, press the Enter button to activate the highlighted advanced setting.
Complete list of Advanced Settings items.
FSPM 00: Advanced Settings
BKR Derating | [Enabled] |
GEN BKR Rating | [30.0A] |
GEN Warmup Delay | [0sec] |
Connect Seq Delay | [10sec] |
AC Disq Priority | [2] |
Nom DC Voltage | [12.0V] |
Circuit1 |
|
Circuit2 |
|
Circuit3 |
|
Circuit4 |
|
Circuit5 |
|
Circuit6 |
|
Circuit7 |
|
Circuit8 |
|
Circuit9 |
|
Circuit10 |
|
Figure 10 Freedom Sequence Advanced Settings Screen
List of advanced settings include:
1.BKR Derating – sets the breaker derating to 80% or 100%.
2.GEN BKR Rating – sets the breaker rating for the generator.
3.GEN Warmup Delay – sets the generator warmup delay from 0 to 240 seconds.
4.Connect Sequence Delay – sets the reconnect delay from 4 to 60 seconds.
5.AC Disq Priority– sets a priority number from 1 (high) to 10 (low).
6.Nom DC Voltage – sets a DC voltage rating of 12.0 V or 24.0 V.
7.Circuit1 to Circuit10 – changes circuit level settings.
Circuit5 to Circuit8.
|