Important Safety Instructions

IMPORTANT: READ AND SAVE THIS OWNERS GUIDE FOR FUTURE

REFERENCE.

This chapter contains important safety instructions when operating the Freedom Sequence Intelligent Power Manager. Each time, before using the Freedom Sequence Intelligent Power Manager, READ ALL instructions and cautionary markings on or provided with the power manager and all appropriate sections of this guide.

NOTE: The Freedom Sequence Intelligent Power Manager contains no user- serviceable parts. For obtaining service, see “Warranty and Return Information” on page 41 for guidance.

NOTE: The Freedom Sequence Intelligent Power Manager must be provided with grounding conductors connected to the AC input/output connections.

ELECTRICAL SHOCK HAZARD

Do not expose the power manager to rain, snow, spray, or bilge water.

Do not operate the power manager if it has received a sharp blow, been dropped, has cracks or openings in the enclosure, or will not close, or otherwise damaged in any other way.

Do not disassemble the power manager.

Disconnect both AC and DC power from the power manager before attempting any maintenance or cleaning or working on any circuits connected to the power manager. See note below.

Do not operate the power manager with damaged or substandard wiring. Make sure that all wiring is in good condition and is not undersized. Use copper conductors only.

Failure to follow these instructions will result in death or serious injury.

NOTE: The power manager has no on/off switch. Circuits are always live when DC and AC input are present.

 

 

iv

 

Freedom Sequence Intelligent Power Manager Owner’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 6
Contents Freedom Sequence Page Contact Information About This Guide Purpose Conventions UsedRelated Information Important Safety Instructions ReferencePrecautions When Placing the Power Manager Explosion HazardRisk of Damage to the Power Manager FCC Information to the UserContents Page Standard Features IntroductionMaterial List Compatible Products and Accessories1 Product/Accessory Product NumberTypical Xanbus System Diagram Xanbus SystemMechanical Features Ports and TerminalsTypical RV Wiring Typical RV Wiring Diagram With Freedom SequencePower Manager Configuration EnterFuncPower Manager Configuration Circuit Status Circuit StatusCont Circuit Status Basic Configuration Settings List of configurable settings includesConfig List of circuit configurable settings includes Circuit ConfigPriority Mode To change the Mode from the Device Status screenMode OperatingAuto Shore Breaker ModeSHR BKR Mode Manual30.0A Breaker RatingsShore Breaker Rating 25.0ARestore Defaults To Restore Defaults from the Device Status screenRestore Defaults Circuit Configuration Config CircuitCircuit Priority To change the priority setting from the Device Status screen Config Circuit ConfigTo change the Load Shed from the Device Status screen EnabledLoad Shed Load ShedAdvanced Settings Improper Configuration DUE to Lack of ExperienceList of advanced settings include Advanced SettingsBKR Derating Config Advanced Settings Breaker DeratingGenerator Breaker Rating Generator Warmup DelayGEN Warmup Delay ScreenConnect Sequence Delay Connect Seq Delay10sec AC Disqualification Priority AC Disc PriorityDC Voltage Setting Nom DC Voltage12.0V Circuit Level Advanced Settings Circuit2Circuit Name AC Relay Settings DC Relay SettingsCircuit Name Circuit3Circuit Type AC LinePriority Generator Soft StartBattery Voltage Triggers Reconnect MarginAuto-Detection of AC Input Source Type 1-Ph/2-Ph Freedom Sequence Operational ConceptsAuto-Detection of AC Input Source Shore/Gen Loading of Shore/Generator Breaker RatingsAC Load Shedding LINE1 L1 LINE2 L2 Using DC Relay to control AC load circuits DC Load SheddingPriority Swapping Between Circuits Override the AC Circuit Load Shedding Freedom Sequence Interaction with Other Xanbus Devices Battery Voltage MeasurementGenerator Run Detection B+ Signal Freedom SW Interactive Charger De-rating ICDFreedom Sequence SCP Menu Map Specifications Warranty and Return Information WarrantyWarranty and Return Information Disclaimer ProductReturn Material Authorization Policy Out of Warranty ServiceReturn Procedure Information About Your System Page Xantrex Technology USA Inc