Xantrex Technology 809-0912 manual Circuit Status, Cont

Page 19

FSequence IPM Owners Guide.book Page 9 Thursday, October 6, 2011 3:33 PM

Circuit Status

NOTE: This example shows screens for a Freedom

Sequence six-circuit model PN: 809-0912.

First five Circuit Status items.

Last five Circuit Status items.

FSPM 00: Status

 

 

 

FSPM 00: Circuit Status

L1

Amps

20.0A

 

 

1

ACLoad1

On

3.0A

L2

Amps

18.5A

 

 

1

Last

Shed Current

 

6.0A

Batt Voltage

12.0V

 

 

2

ACLoad2

On

4.5A

Circuit Status

 

 

 

 

2

Last

Shed Current

 

4.0A

 

 

 

 

 

 

 

 

 

 

 

Enter Func Enter Func

2

1

3

From the device Status screen, scroll

Display each item using the Up and

down (1) until Circuit Status is

Down buttons (3). The statuses of the

highlighted then, press Enter (2) to

first five circuits are displayed.

bring up the circuit status screen.

 

FSPM 00: Circuit Status

1

ACLoad1

On 3.0A

1

Last Shed Current

6.0A

2

ACLoad2

On 4.5A

2

Last Shed Current

4.0A

3

ACLoad3

On 2.5A

3

Last Shed Current

2.5A

4

ACLoad4

On 2.3A

4

Last She Current

2.0A

5

ACLoad5

On 3.7A

5

Last Shed Current

1.0A

Cont

FSPM 00: Circuit Status

4

Last

She Current

2.0A

5

ACLoad5

On 3.7A

5

Last

Shed Current

1.0A

Cont

EnterFunc

54

To display the statuses of the next set of circuits, scroll down (4) until Cont is highlighted then, press Enter (5) to bring up the second circuit status screen.

NOTE: Use the Func button to exit out of each screen.

FSPM 00: Circuit Status

6

ACLoad6

On 3.0A

6

Last Shed Current

 

4.0A

7

DCLoad1

 

On N/A

7

Last Shed Current

 

N/A

8

DCLoad2

 

On N/A

8

Last Shed Current

 

N/A

9

DCLoad3

 

On N/A

9

Last She Current

 

N/A

10 DCLoad4

 

On N/A

10 Last Shed Current

N/A

Figure 7 Freedom Sequence Circuit Status Screen

 

 

975-0593-01-01

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 19
Contents Freedom Sequence Page Contact Information Purpose Conventions Used About This GuideRelated Information Reference Important Safety InstructionsExplosion Hazard Precautions When Placing the Power ManagerFCC Information to the User Risk of Damage to the Power ManagerContents Page Introduction Standard FeaturesMaterial List Product/Accessory Product Number Compatible Products and Accessories1Xanbus System Typical Xanbus System DiagramPorts and Terminals Mechanical FeaturesTypical RV Wiring Diagram With Freedom Sequence Typical RV WiringEnterFunc Power Manager ConfigurationPower Manager Configuration Circuit Status Circuit StatusCont Circuit Status List of configurable settings includes Basic Configuration SettingsConfig Circuit Config List of circuit configurable settings includesPriority Operating To change the Mode from the Device Status screenMode ModeManual Shore Breaker ModeSHR BKR Mode Auto25.0A Breaker RatingsShore Breaker Rating 30.0ATo Restore Defaults from the Device Status screen Restore DefaultsRestore Defaults Config Circuit Circuit ConfigurationCircuit Priority Config Circuit Config To change the priority setting from the Device Status screenLoad Shed EnabledLoad Shed To change the Load Shed from the Device Status screenImproper Configuration DUE to Lack of Experience Advanced SettingsAdvanced Settings List of advanced settings includeBKR Derating Breaker Derating Config Advanced SettingsScreen Generator Warmup DelayGEN Warmup Delay Generator Breaker RatingConnect Seq Delay Connect Sequence Delay10sec AC Disc Priority AC Disqualification PriorityNom DC Voltage DC Voltage Setting12.0V Circuit2 Circuit Level Advanced SettingsCircuit Name DC Relay Settings AC Relay SettingsCircuit3 Circuit NameAC Line Circuit TypeGenerator Soft Start PriorityReconnect Margin Battery Voltage TriggersLoading of Shore/Generator Breaker Ratings Freedom Sequence Operational ConceptsAuto-Detection of AC Input Source Shore/Gen Auto-Detection of AC Input Source Type 1-Ph/2-PhAC Load Shedding LINE1 L1 LINE2 L2 DC Load Shedding Using DC Relay to control AC load circuitsPriority Swapping Between Circuits Override the AC Circuit Load Shedding Freedom SW Interactive Charger De-rating ICD Battery Voltage MeasurementGenerator Run Detection B+ Signal Freedom Sequence Interaction with Other Xanbus DevicesFreedom Sequence SCP Menu Map Specifications Warranty Warranty and Return InformationWarranty and Return Information Product DisclaimerOut of Warranty Service Return Material Authorization PolicyReturn Procedure Information About Your System Page Xantrex Technology USA Inc