| TROUBLESHOOTING & REPAIR | |
| TROUBLESHOOTING GUIDE | Observe Safety Guidelines |
|
| detailed in the beginning of this manual. |
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | |
|
|
|
|
| OUTPUT PROBLEMS |
|
|
Low weld output and low auxiliary | 1. The generator brushes may be | 1. | Perform the Rotor Voltage |
output. | worn. See the Maintenance |
| Test. |
| section of this manual or con- | 2. | If the rotor voltage is low, the |
| tact your local Lincoln Electric | ||
|
| field capacitor (C1) or the field | |
| Authorized Field Service |
| |
|
| rectifier bridge (D1) may be | |
| Facility. |
| |
|
| faulty. Test or replace. | |
|
|
| |
| 2. The engine RPM may be low. | 3. | Check the rheostat (R1). |
|
| ||
|
|
| Normal resistance is 3.3 ohms. |
|
|
| See Wiring Diagram. |
|
| 4. | The rotor may be faulty. |
|
|
| Perform the Rotor Resistance |
|
|
| Test. |
|
| 5. | The engine RPM may be low. |
|
|
| Perform the Engine Throttle |
|
|
| Adjustment Test. |
|
| 6. | If the engine idle RPM is okay, |
|
|
| the engine may have lost |
|
|
| horsepower and be in need of |
|
|
| major repair. |
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
WELDANPOWER 125