| TROUBLESHOOTING & REPAIR |
| |
| TROUBLESHOOTING GUIDE | Observe Safety Guidelines | |
|
| detailed in the beginning of this manual. |
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
| ||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
| ||
|
|
|
|
| |
| ENGINE PROBLEMS |
|
|
| |
Engine will not go to high idle when | 1. Make sure the welding cables | 1. Make sure the #W1 lead is | |||
attempting to weld. Welding output | and connections are tight. | looped through | the | current | |
is normal when the idler control |
| transformer. | See | Wiring | |
switch is in the “HIGH” position. |
| Diagram. |
|
| |
Automatic idle function works |
| 2. Check for loose or faulty con- | |||
properly when the auxiliary power |
| ||||
| nections on the heavy current | ||||
is loaded. |
| ||||
| carrying leads connected to the | ||||
|
| ||||
|
| output terminals, the choke (L1) | |||
|
| and the output rectifier bridge | |||
|
| (D2). |
|
| |
|
|
| |||
Engine will not go to high idle when | 1. Make sure that the auxiliary | 1. Make sure that leads #3A and | |||
using the auxiliary power. Auxiliary | load is more than 100 watts. | #6A are looped through the cur- | |||
power output is normal when the | 2. Check for loose or faulty con- | rent transformer | in the | proper | |
idler control switch is in the “HIGH” | direction. See Wiring Diagram. | ||||
nections at the auxiliary output | |||||
position. Automatic idle function |
|
|
| ||
receptacles. |
|
|
| ||
works properly when the welding |
|
|
| ||
|
|
|
| ||
output is loaded. |
|
|
|
| |
|
|
|
|
|