| TROUBLESHOOTING & REPAIR |
| ||
| Observe Safety Guidelines |
|
| TROUBLESHOOTING GUIDE | |
| detailed in the beginning of this manual. |
|
|
| |
|
|
|
| ||
| PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | ||
| (SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | ||
|
|
|
|
|
|
|
|
| ENGINE PROBLEMS |
|
|
| Engine will not start. | 1. | Make sure the RUN/STOP | 1. Check the fuel line for breaks or | |
|
|
| Switch is in the “RUN” position. | obstructions. | |
|
| 2. | Make sure the fuel shut off valve | 2. The spark plug may be faulty. | |
|
|
| is in the open position. | Replace. | |
|
| 3. | Make sure the engine has ade- | 3. Service the engine as outlined | |
|
|
| quate fuel and oil. | in the Maintenance section of | |
|
| 4. | Adjust the choke to prevent car- | this manual. | |
|
|
|
| ||
|
|
| buretor flooding. | 4. The engine ignition module may | |
|
| 5. | Check the spark plug wire for | be faulty. Consult Briggs & | |
|
| Stratton Service. | |||
|
|
| loose or faulty connections. | ||
|
|
|
|
|
Engine runs erratic or stops run- 1. | The oil level may be low, acti- | 1. | If the oil level is correct, the oil | |
ning. | vating the engine oil level shut- |
| level shutdown switch may be | |
| down system. Check oil level. |
| faulty. Remove the lead running | |
2. | Check the spark plug wire for |
| from the oil level switch to the | |
| ignition module. | If the engine | ||
| loose or faulty connection. |
| ||
|
| runs normally, the oil level | ||
|
|
| ||
3. | The spark plug may be faulty. |
| switch is faulty. | Replace. DO |
| Replace. |
| NOT OPERATE | THE ENGINE |
4. | The fuel and air mixture may be |
| WITHOUT OIL | LEVEL PRO- |
| TECTION. |
| ||
| out of adjustment. Consult the |
|
| |
|
|
|
| |
| Briggs & Stratton Owner’s | 2. | The engine may require service | |
| Manual. |
| to the head or carburetor. | |
5. | The fuel supply may be conta- |
|
|
|
| minated with water. |
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call