Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115 VAC SUPPLY)
HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM
1 Period = 16.2 ms @ 3700 rpm
CH1
0 volts
50 volts | 5 ms |
This is the typical AC output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.
Note: Scope probes connected at machine 115 VAC receptacle.
SCOPE SETTINGS
Volts/Div | 50V/Div. |
Horizontal Sweep | 5 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|
WELDANPOWER 125