TROUBLESHOOTING & REPAIR
TROUBLESHOOTING & REPAIR
TROUBLESHOOTING GUIDE |
| Observe Safety Guidelines | |||
| detailed in the beginning of this manual. | ||||
|
|
|
|
| |
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
|
| |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
| ||
|
|
|
|
|
|
| ENGINE PROBLEMS |
|
|
|
|
The welding arc is “cold.” The | 1. Check for loose or faulty con- | 1. With the output control at max- | |||
engine runs normally. The auxiliary | nections at the weld output ter- | imum, check for the correct | |||
power functions normally. | minals and welding cable con- | open circuit voltage (OCV) at | |||
| nections. | the welder output terminals (75 | |||
| 2. The welding cable may be too | - 82 VDC). If the correct open | |||
| circuit voltage is present at the | ||||
| long or coiled, causing an | ||||
| output | terminals, | check | for | |
| excessive voltage drop. | ||||
| loose connections on the heavy | ||||
|
| ||||
|
| current carrying leads inside the | |||
|
| WELDANPOWER | 125. | See | |
|
| Wiring Diagram. |
|
| |
|
| 2. If the OCV is low at the welder | |||
|
| output | terminals, | perform | the |
|
| Engine | Throttle | Adjustment | |
|
| Test. |
|
|
|
|
| 3. Perform the Output Rectifier | |||
|
| Bridge Test. |
|
| |
|
| 4. Check for shorted or grounded | |||
|
| windings in the choke (L1). |
| ||
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
WELDANPOWER 125